pressure switch TDS DSP

Operation

Switching the device on

1. Open a consumer at the end of the pressure side, e.g.

water tap or garden sprayer so that any remaining air in
the line is able to escape.

2. Connect the mains plug of the pump with the plug (8) of

the pressure switch.

3. Connect the mains plug of the pressure switch with a

safety socket.

ð

The LED 

Power

 (5) is illuminated.

ð

The pressure switch activates the pump.

ð

After approx. 20 to 25 seconds, the pump has built up
the operating pressure. While the pump is in operation,
the LED 

On

 (7) is illuminated.

4. Close the tap on the pressure side when the desired

amount of water has been supplied and the air was able to
escape.

ð

The pump continues to operate a little longer, until the
operating pressure that is set in the pressure switch is
reached.

ð

If the pressure switch detects that the flow rate is too
low, it automatically switches off the pump. This serves
as a protection against the pump running dry. In this
case, the LED 

Failure

 (6) is illuminated. If so, check

whether the suction hose connected to the pump is
correctly positioned, whether a shut-off valve in the
suction hose is accidentally closed or whether a filter is
contaminated.

Info

It is helpful to fill the suction hose with water to
support the suction procedure of the pump. To do so,
the end of the suction hose has to be provided with a
backflow preventer! Please observe the instructions of
the pump.

If there is no more air in distribution network, opening the water
tap causes the water pressure to drop. This is detected by the
pressure switch. It will automatically activate the garden pump
for as long as the water tap is opened.
After closing the water tap, the pressure in the distribution
network increases. Then the pressure switch switches off after
a few seconds.

Reset

If the pump runs dry and the water flow rate falls below the set
minimum value, the pressure switch switches off the pump for
reasons of safety. The LED 

Failure

 (6) is illuminated. Please

proceed as follows to restart the pressure switch and the pump:

1. Stop the pump running dry by filling water into the suction

hose (if possible) or into the pump. For this purpose, many
pumps are equipped with a water filler neck. If necessary,
find out more in the instructions of your pump.

2. When you eliminated the dry run of the pump, press the

button 

Reset

 (4) at the pressure switch.

ð

The LED 

Failure

 (6) goes out.

ð

The pressure switch activates the pump.

ð

The LED 

On

 (7) is illuminated for as long as the pump is

in operation.

Setting the switch-on pressure

Warning

Setting the switch-on pressure may only be carried out
by specialist companies for water installation.

The device is equipped with a pressure setting screw (1). The
setting screw is used to set the pressure value at which the
device switches on the connected pump. For more detailed
information about the required pump pressure please refer to
the start-up chapter.
Please proceed as follows to set the switch-on pressure:

1. Turn the pressure setting screw (1) towards the minus sign

to reduce the switch-on pressure. The minimum switch-on
pressure (screw all the way to the minus sign) is 1.5 bar.

ð

Every 360° turn reduces the pressure for approx.
0.2 bar.

2. Turn the pressure setting screw (1) towards the plus sign

to increase the switch-on pressure. The maximum switch-
on pressure (screw all the way to the plus sign) is 2.5 bar.

ð

Every 360° turn increases the pressure for approx.
0.2 bar.

1

Note for setting the switch-on pressure:

The switch-on pressure is set too low:

– When the tap is opened, the pump does not start

operating.

– The LED 

Power

 (5) is illuminated in green.

– Turn pressure setting screw towards the plus sign.

The switch-on pressure is set too high:

– The dry-run protection is activated and the pump does

not start operating.

– The LEDs 

Power

 (5) and 

Failure

 (6) are illuminated

(green / yellow).

– Turn pressure setting screw towards the minus sign.

Switch-on pressure is set close to the maximum pressure
of the pump:

Содержание TDS DSP

Страница 1: ...TRT BA TDPDSP TC2019 61 002 EN TDS DSP EN OPERATING MANUAL PRESSURE SWITCH...

Страница 2: ...44132 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all...

Страница 3: ...he cable for damage The use of extension cables which are not approved for outdoor use can result in injuries due to electric shock Before performing any work on the device in case of leaks in the wat...

Страница 4: ...ust be able to read and understand electric circuit diagrams to put electrical systems into service and to maintain them to wire control cabinets to ensure the functionality of electrical components a...

Страница 5: ...ed pump The restart button on the pressure switch is used for restarting the connected pump manually e g when the device switches the pump off because the pump is running dry In addition the device is...

Страница 6: ...tion is protected from weather exposure and wet conditions Required pump pressure The required operating pressure of the pump to be connected depends on the height difference between pump and highest...

Страница 7: ...t with the consumer side The device comes with 1 external thread The diameter of the connected lines may not be smaller 4 If the device is not equipped with a mains plug have the power cable for the p...

Страница 8: ...m value the pressure switch switches off the pump for reasons of safety The LED Failure 6 is illuminated Please proceed as follows to restart the pressure switch and the pump 1 Stop the pump running d...

Страница 9: ...be sucked by the pump without any problems Check whether the LED Failure 6 is illuminated If so press the Reset 4 button If the pump is still not starting to operate make sure that the water in the wa...

Страница 10: ...ump connection without mains plug 3 phase A switching device must be interposed when three phase pumps are used The chosen capacity for the protection has to be compatible with the pump Disposal The i...

Страница 11: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: