Trotec TAC M Скачать руководство пользователя страница 1

TRT-BA-TAC-V+II-TAC-M-II-TC210831TTRT01-001-EN

TAC V+ II / TAC M II

EN

ORIGINAL INSTRUCTIONS

HIGH-PERFORMANCE AIR
PURIFIER

Содержание TAC M

Страница 1: ...TRT BA TAC V II TAC M II TC210831TTRT01 001 EN TAC V II TAC M II EN ORIGINAL INSTRUCTIONS HIGH PERFORMANCE AIR PURIFIER...

Страница 2: ...n minor or moderate injury Note This signal word indicates important information e g material damage but does not indicate hazards Info Information marked with this symbol helps you to carry out your...

Страница 3: ...during operation Do not sit on the device This appliance is not a toy Keep away from children and animals Do not leave the device unattended during operation Check accessories and connection parts fo...

Страница 4: ...instructions especially the Safety chapter Instructed person Instructed persons have been informed of the tasks they were entrusted with as well as of potential hazards resulting from inappropriate be...

Страница 5: ...les since the device is able to perform large volume air intakes of contaminated room air All thanks to effective H14 HEPA filtration and a flexibly adjustable air circulation for the respective zone...

Страница 6: ...l data After transporting the device proceed as follows Set up the device in an upright position after transport Storage When the device is not being used observe the following storage conditions dry...

Страница 7: ...attach additional optional sound protection caps Attaching mounting brackets For additional securing of the device the optional mounting brackets are recommended to fasten the device to the wall The...

Страница 8: ...Please proceed as follows to unlock the screen lock 1 Press the Locked button for 2 seconds If a PIN has been previously set press the Locked button and enter the PIN Then press Confirm The screen loc...

Страница 9: ...uired to unlock the screen If you select the Screen lock on with PIN setting a screen for entering a PIN appears on the display The PIN can be freely selected Press the Accept button to confirm the PI...

Страница 10: ...ons are displayed next to each other HEPA filter TAC V 16 09 Fan 1 600 m h 3 SupplyTemp 21 0 C Duration 12 min Silent Boost Setting the Silent function The Silent function allows you to adjust the fan...

Страница 11: ...daptation will be adopted without any further confirmation Once the device is switched on the timer starts running and will switch off the device after the set time has been expired Setup weekly timer...

Страница 12: ...ton in the main menu to activate the current switching time The On and Off buttons will remain active Main menu off auto on Setpoint configuration back Setting the fan stage You can set the fan stage...

Страница 13: ...kindergartens or public buildings it is sufficient to regenerate the filter once a week If the air purifier is used in cool areas with high humidity levels e g in slaughterhouses or in the food indus...

Страница 14: ...the device If the device is not starting have the electrics checked by a specialist company or by Trotec The overheating protection may have been tripped Have a specialist electrical company or Trote...

Страница 15: ...ro tection motor The device is overheating Disconnect the device from the mains and allow it to cool down Maintenance The device is designed for long hours of operation with minimum maintenance effort...

Страница 16: ...or replace the prefilter fleece X Checking the safety temperature limiter X Check the attachment screws X X Test run X with thermal decontamination without thermal decontamination Maintenance and care...

Страница 17: ...and lint free cloth Make sure that no moisture enters the housing Protect electrical components from moisture Do not use any aggressive cleaning agents such as cleaning sprays solvents alcohol based o...

Страница 18: ...screws on the air inlet 5 on both sides and pull out the air inlet towards the front of the device 2 Remove the air filter I II III 3 Insert the new air filter into the device 4 Put the air inlet 5 b...

Страница 19: ...2 ePM10 85 ISO 16890 High temperature particulate air filter TROTEC HEPA H14 Heat Resistant EN 1822 TROTEC HEPA H14 Heat Resistant EN 1822 Mains connection 220 240 V 50 60 Hz 220 240 V 50 60 Hz Averag...

Страница 20: ...W ZiehlAbegg P10002324 bn L1 RS A bk bu N RS B bn ye gn PE wh COM wh NC rd 10V ye 0 10V bu GND gn D1 wh A1 K3G250 PR17 Y5 230Vac 820W EBM P10007839 bk L1 RS A wh bu N RS B bn PE ye gn PE wh COM wh NC...

Страница 21: ...ource 0 3Amax Analog Out 0 10V 4 20mA 24Vdc Digital In Analog In 0 10V 4 20mA Touch Power Cartridge1 Cartridge2 4K1 O0 O1 PE O2 O3 AQ0 AQ0 AQ1 AQ1 I0 I1 I2 I3 I4 I5 AI0 AI0 AI1 AI1 X1 8 3 X1 6 3 X1 4...

Страница 22: ...leat F7 plastic frame 496x496x48mm with fleece 3 Fan holder T0000734 13 Air filter HEPA H14 417x417x292mm 6mm gasket heat resistant 4 Fan TAC 14 Mains connection C14 L N PE 10A 250V AC with fuse holde...

Страница 23: ...ing clip mounting clip for relay series 66 4 Control system PLC IDEC Touch compact FT1A M14SAB 17 Relay power 30A 2 changeover contacts 5 Temperature limiter STB 50 300 C S L 2000mm 18 Power supply un...

Страница 24: ...ositions of the components mentioned in these instructions A B 3 4 A 1 2 7 6 5 B 1 2 1 2 No Spare part No Spare part 1 Washer DIN 9021 5 3x 15x1 2 VZ 5 Protective cap M10 SW17 plastics black 2 Hexagon...

Страница 25: ...in these instructions A 1 6 DETAIL A MA STAB 2 2 5 3 2 5 7 4 8 No Spare part No Spare part 1 Heating rod tubular heating element 277V 450W 7 Washer DIN 125 A 4 3x 9x0 8 VZ 2 Serrated lock washer 4 3x...

Страница 26: ...ed plug round insert LDPE medium grey 111139 3 Support T0001516 16 Hexagon screw DIN 933 M5x45 VZ 4 Support T0001517 17 Detent edged washer 5 1 x 10 2 x 1 VZ 5 Connection T0001518 18 Detent edged wash...

Страница 27: ...ts differ from those describing the positions of the components mentioned in these instructions A 2 1 3 A 1 1 4 5 No Spare part No Spare part 1 Bottom housing T0000665 4 Allen screw Liko DIN7380 1 M6x...

Страница 28: ...antle T0001344 13 Hexagon socket countersunk screw DIN 7991 M 5x6 VZ 3 Finger protection T0001343 14 Washer DIN 125 A 5 3x 10x1 VZ 4 Heat shield plate T0001352 15 Hexagon nut DIN 934 M5 VZ 5 Cylinder...

Страница 29: ...STAB 1 2 4 DETAIL B MA STAB 1 2 6 DETAIL E MA STAB 1 2 3 3 2 DETAIL C MA STAB 1 2 5 7 DETAIL D MA STAB 1 2 5 8 No Spare part No Spare part 1 Silencer T0000706 6 Allen screw Liko DIN7380 1 M5x12 VZ bl...

Страница 30: ...numbers of the spare parts differ from those describing the positions of the components mentioned in these instructions 1 2 3 No Spare part No Spare part 1 Fan fan TAC V 3 Protective grid bolt circle...

Страница 31: ...tances potentially contained in the equipment Declaration of conformity Declaration of conformity in accordance with the EC Machinery Directive 2006 42 EC Annex II Part 1 Section A We Trotec GmbH decl...

Страница 32: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...