cable drum PVD2 / PVD3 / PVD4

Insert the mains plug into a properly secured mains
socket.

Observe the following safety rules when performing work
on the electrical equipment: 1. De-energise, 2. Secure
against restart, 3. Verify de-energised state, 4. Earth and
short-circuit, 5. Cover or fence off live parts.

Before carrying out maintenance, care or repair work on
the device, remove the mains plug from the mains socket.
Hold onto the mains plug while doing so.

Do not under any circumstances use the device if you
detect damages on the mains plug or power cable. If the
supply cord is damaged, it must be replaced by the
manufacturer, his service agent or similarly qualified
persons in order to avoid a hazard. Defective power cables
pose a serious health risk!

Observe the storage and operating conditions as given in
the Technical data chapter.

Do not expose the device to heat or direct sunlight.

Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.

Any operation other than as described in this manual is
prohibited. Non-observance renders all claims for liability
and guarantee null and void.

Intended use

The device serves as extension line for electrical connections.
For the PVD2 model, the sum of the maximum permissible
connected load must not exceed 3600 watts when unreeled and
1300 watts when rolled up. For the PVD3 and PVD4 models, the
sum of the maximum permissible connected load must not
exceed 3500 watts when unreeled and 1250 watts when rolled
up.

Improper use

Do not use the device in potentially explosive areas. Do not
place the device on wet or flooded ground.
Any unauthorised changes, modifications or alterations to the
device are forbidden.

Personnel qualifications

People who use this device must:

have read and understood the operating manual, especially
the Safety chapter.

Initial start-up and maintenance tasks which require the
housing to be opened must only be carried out by qualified
electricians.

Symbols on the device

Note

Do not remove any safety signs, stickers or labels from
the device. Keep all safety signs, stickers and labels in
legible condition.

The following safety signs and labels are attached to the cable
drum PVD2:

Symbols

Meaning

1300W 230V

This symbol located on the device indicates
that, when rolled up, the maximum
connected load must not exceed
1300 watts.

3600W 230V

This symbol located on the device indicates
that, when unreeled, the maximum
connected load must not exceed
3600 watts.

The following safety signs and labels are attached to the cable
drums PVD3 and PVD4:

Symbols

Meaning

1250W 230V

This symbol located on the device indicates
that, when rolled up, the maximum
connected load must not exceed
1250 watts.

3500W 230V

This symbol located on the device indicates
that, when unreeled, the maximum
connected load must not exceed
3500 watts.

Содержание PVD2

Страница 1: ...TRT BA PVD2 PVD3 PVD4 TC2019 41 002 EN PVD2 PVD3 PVD4 EN OPERATING MANUAL CABLE DRUM ...

Страница 2: ...tps hub trotec com id 43686 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference This ...

Страница 3: ...0 watts when unreeled and 1300 watts when rolled up For the PVD3 and PVD4 models the sum of the maximum permissible connected load must not exceed 3500 watts when unreeled and 1250 watts when rolled up Improper use Do not use the device in potentially explosive areas Do not place the device on wet or flooded ground Any unauthorised changes modifications or alterations to the device are forbidden P...

Страница 4: ...ncy disconnect the device from the mains feed in Pull the mains plug 2 Do not reconnect a defective device to the mains Information about the device Device description The cable drum PVD2 is fitted with a black cable of 25 m length The cable drum PVD3 is fitted with a black cable of 40 m length the cable drum PVD4 is fitted with a yellow cable of 40 m length The cable drum comes equipped with dust...

Страница 5: ...254 mm x 338 mm x 409 mm Weight packaging excluded approx 8 kg approx 10 kg Transport and storage Note If you store or transport the device improperly the device may be damaged Note the information regarding transport and storage of the device Transport To make the device easier to transport it is fitted with a carry handle Before transporting the device observe the following Roll up the cable com...

Страница 6: ...he mains socket Clean the device with a soft damp and lint free cloth Ensure that no moisture enters the housing Protect electrical components from moisture Do not use any aggressive cleaning agents such as cleaning sprays solvents alcohol based or abrasive cleaners to dampen the cloth Wipe the housing dry after cleaning Errors and faults The device has been checked for proper functioning several ...

Страница 7: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Отзывы: