SpeedMarker 300 /
ProMarker 300
Ausgabe 1.0
Technische Änderungen vorbehalten.
TROTEC Produktions- u. Vertriebs GmbH
Linzer Straße 156, A
– 4600 Wels
Seite
11
von 42
Laser Safety Information
To assess the potential dangers laser systems pose, they are classified into 5 safety classes: 1,
2, 3a, 3b and 4. Trotec SpeedMarker 300 / ProMarker 300 fiber is a device of class 2 (USA: Class
II) and class 4 (USA: Class IV) with pass through option
Please note that improper operation of the device can override the status of safety class 2 and
can cause the emission of harmful radiation.
This laser system contains a YTTERBIUM FIBER LASER of class 4 that emits intensive and in-
visible laser radiation. Without safety precautions the direct radiation or even diffuse reflected ra-
diation is dangerous!
Without safety precautions, the following risks exist with exposure to laser radiation:
Eyes:
Burns to the retina for
NIR (Near Infra Red) LASER
Skin: Burns
Clothing: Danger of fire
Never try to modify or disassemble the laser and do not try to start up a system that had been
modified or disassembled!
Dangerous radiation exposure can result from the use of operation or adjustment equipment other
than that described here, and if different operational methods are performed.
Service technicians using the service plug are required to wear standard laser safety glasses for
NIR (Near Infra Red)
lasers (wavelength 1060 nm).