compressor PCPS 10-1100

Your device still does not operate correctly after these
checks?

Please contact the customer service. If necessary, bring the
device to an authorized specialist electrical company or to
Trotec for repair.

Maintenance

Activities required before starting maintenance

Warning of electrical voltage

Do not touch the mains plug with wet or damp hands.

Switch off the device.

Hold onto the mains plug while pulling the power cable out
of the mains socket.

Allow the device to cool down completely.

Warning of electrical voltage
Maintenance tasks which require the housing to be
opened must only be carried out by authorised
specialist companies or by Trotec.

Particularly during cleaning and maintenance, make sure
that there is no residual pressure left in the system. Bleed
the system by pulling the trigger of the connected
compressed-air gun.

Wear hearing protection.

The sound pressure level L

pA

 of this device amounts to

94.1 dB(A). Wear hearing protection during all
maintenance activities requiring the device to be
switched on.

Notes on maintenance

Inside the device, there are no parts that need to be maintained
or lubricated by the user.

Cleaning

The device should be cleaned before and after each use.

Note

The device does not have to be lubricated after
cleaning.

Warning of electrical voltage

There is a risk of a short-circuit due to liquids
penetrating the housing!
Do not immerse the device and the accessories in
water. Make sure that no water or other liquids can
enter the housing.

Clean the device with a soft, damp and lint-free cloth.
Ensure that no moisture enters the housing. Protect
electrical components from moisture. Do not use any
aggressive cleaning agents such as cleaning sprays,
solvents, alcohol-based or abrasive cleaners to dampen
the cloth.

Dry the device with a soft, lint-free cloth.

Dry the bits with a soft, lint-free cloth.

Keep the ventilation openings free from dust deposits to
prevent overheating of the motor.

Disposal

The icon with the crossed-out waste bin on waste

electrical or electronic equipment stipulates that this equipment
must not be disposed of with the household waste at the end of
its life. You will find collection points for free return of waste
electrical and electronic equipment in your vicinity. The
addresses can be obtained from your municipality or local
administration. For further return options provided by us please
refer to our website www.trotec24.com.
The separate collection of waste electrical and electronic
equipment aims to enable the re-use, recycling and other forms
of recovery of waste equipment as well as to prevent negative
effects for the environment and human health caused by the
disposal of hazardous substances potentially contained in the
equipment.

Содержание PCPS 10-1100

Страница 1: ...TRT BA PCPS10 1100 TC 002 EN PCPS 10 1100 EN ORIGINAL INSTRUCTIONS COMPRESSOR...

Страница 2: ...r hearing protection Information marked with this symbol indicates that you should wear hearing protection Wear safety glasses Information marked with this symbol indicates that you should wear eye pr...

Страница 3: ...a power tool outdoors use an extension cord suitable for outdoor use Use of a cord suitable for outdoor use reduces the risk of electric shock If operating a power tool in a damp location is unavoida...

Страница 4: ...s maintained Device specific safety warnings for compressors and blow out guns Do not use the device in potentially explosive rooms Ensure that the side of the device where the air inlet is found is k...

Страница 5: ...nd beach items for measuring the current pressure level of an inflatable object for generating compressed air for pneumatic tools whilst adhering to the technical data Info Please note that the pressu...

Страница 6: ...distance from heat sources Note If you store or transport the device improperly the device may be damaged Note the information regarding transport and storage of the device Note The device is not sui...

Страница 7: ...ation 1 Transport handle 2 On off switch with protective cover 3 Storage compartment for compressed air hose 4 Compressed air hose with quick coupling 5 3 fold nozzle attachments 6 Ball needle 7 Unive...

Страница 8: ...ce being processed Transport and storage Note If you store or transport the device improperly the device may be damaged Note the information regarding transport and storage of the device Transport Bef...

Страница 9: ...m the system 2 Pull back the sleeve 28 at the quick coupling 21 of the compressed air hose 4 Hold the quick coupling steady in your hand to prevent uncontrolled release 28 3 Take the released compress...

Страница 10: ...as follows The device is switched off 1 If the compressed air gun is already connected to the compressor disconnect it from the compressor first see chapter Disconnecting the compressed air gun 2 Use...

Страница 11: ...scale for psi Measures the pressure in psi 27 Indicator scale for bar Measures the pressure in bar 28 Indicator needle Indicates the current pressure value in psi and bar Checking the pressure 1 Conn...

Страница 12: ...r becomes sluggish and can be difficult or impossible to start up Do not use the device at an temperatures below 5 C The device is running but there is no apparent inflation The pressure gauge shows n...

Страница 13: ...after cleaning Warning of electrical voltage There is a risk of a short circuit due to liquids penetrating the housing Do not immerse the device and the accessories in water Make sure that no water o...

Страница 14: ...l Product PCPS 10 1100 Product type compressor Year of manufacture as of 2018 Guaranteed sound power level LWA 97 dB A Relevant EU directives 2000 14 EC 8 May 2000 2005 88 EC 14 Dec 2005 2011 65 EU 1...

Страница 15: ......

Страница 16: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: