10
EN
compressor PCPS 10-1100
If you want to use the compressed-air gun with a Schrader
valve, the compressed-air gun is already fully assembled and
can be directly connected using the quick-release lever (22).
If you want to use one of the valve adapters (6, 7, 8, 17), please
proceed with the following steps:
ü
The device is switched off.
1. Push the quick-release lever (22) at the hose (15) of the
compressed-air gun and insert the desired valve
adapter (6, 7, 8, 17).
17
6
7
8
22
Exchanging the nozzle
To blow up inflatable items, you can connect the following
nozzles to the compressed-air hose via the supplied nozzle
adapter (9).
No.
Description
23
To be used with inflatables fitted with a vent valve
24
To be used with inflatables fitted with a screw-on valve
25
To be used with standard valves with an inner diameter
of 8 mm or more
To connect one of the nozzles via the nozzle adapter, please
proceed as follows:
ü
The device is switched off.
1. Push the quick-release lever (22) at the hose (15) of the
compressed-air gun and insert the nozzle adapter (9).
2. Attach the desired nozzle (23, 24, 25) to the nozzle
adapter (9).
23
9
24
25
Connecting the blow-out adapter
To remove dust and dirt in poorly accessible locations, use the
blow-out adapter (16).
To connect the blow-out adapter (16), please proceed as
follows:
ü
The device is switched off.
1. If the compressed-air gun is already connected to the
compressor, disconnect it from the compressor first (see
chapter Disconnecting the compressed-air gun).
2. Use an open-end wrench (SW14) to disconnect the
hose (15) from the compressed-air gun (12) by unscrewing
it counter-clockwise.
3. Fit the blow-out adapter (16) into the internal thread and
fasten it clockwise.
4. Connect the compressed-air gun to the compressor again
(see chapter Connecting the compressed-air gun).