background image

10

EN

compressor PCPS 10-1100

If you want to use the compressed-air gun with a Schrader
valve, the compressed-air gun is already fully assembled and
can be directly connected using the quick-release lever (22). 
If you want to use one of the valve adapters (6, 7, 8, 17), please
proceed with the following steps:

ü

The device is switched off.

1. Push the quick-release lever (22) at the hose (15) of the

compressed-air gun and insert the desired valve
adapter (6, 7, 8, 17).

17

6

7

8

22

Exchanging the nozzle

To blow up inflatable items, you can connect the following
nozzles to the compressed-air hose via the supplied nozzle
adapter (9).

No.

Description

23

To be used with inflatables fitted with a vent valve

24

To be used with inflatables fitted with a screw-on valve

25

To be used with standard valves with an inner diameter
of 8 mm or more

To connect one of the nozzles via the nozzle adapter, please
proceed as follows:

ü

The device is switched off.

1. Push the quick-release lever (22) at the hose (15) of the

compressed-air gun and insert the nozzle adapter (9).

2. Attach the desired nozzle (23, 24, 25) to the nozzle

adapter (9).

23

9

24
25

Connecting the blow-out adapter

To remove dust and dirt in poorly accessible locations, use the
blow-out adapter (16).
To connect the blow-out adapter (16), please proceed as
follows:

ü

The device is switched off.

1. If the compressed-air gun is already connected to the

compressor, disconnect it from the compressor first (see
chapter Disconnecting the compressed-air gun).

2. Use an open-end wrench (SW14) to disconnect the

hose (15) from the compressed-air gun (12) by unscrewing
it counter-clockwise.

3. Fit the blow-out adapter (16) into the internal thread and

fasten it clockwise.

4. Connect the compressed-air gun to the compressor again

(see chapter Connecting the compressed-air gun).

Содержание PCPC 10-1100

Страница 1: ...TRT BA PCPS10 1100 TC220330TTRT03 005 EN PCPS 10 1100 EN ORIGINAL INSTRUCTIONS COMPRESSOR...

Страница 2: ...ormation marked with this symbol indicates that you should wear eye protection Wear a protective mask Information marked with this symbol indicates that you should wear a protective mask Wear protecti...

Страница 3: ...door use Use of a cord suitable for outdoor use reduces the risk of electric shock If operating a power tool in a damp location is unavoidable use a residual current device RCD protected supply Use of...

Страница 4: ...intained Device specific safety warnings for compressors and blow out guns Do not use the device in potentially explosive rooms or areas and do not install it there Make sure that the suction side is...

Страница 5: ...ed on its rubber feet or the bottom side Never exceed the inclination angle of 10 vertical pos or 15 horizontal pos Intended use Only use the device PCPS 10 1100 for inflating car tyres bicycle tyres...

Страница 6: ...and does not belong in the hands of children Warning Risk of suffocation Do not leave the packaging lying around Children may use it as a dangerous toy Caution Keep a sufficient distance from heat sou...

Страница 7: ...ation 1 Transport handle 2 On off switch with protective cover 3 Storage compartment for compressed air hose 4 Compressed air hose with quick coupling 5 3 fold nozzle attachments 6 Ball needle 7 Unive...

Страница 8: ...Wear hearing protection Excessive noise can lead to hearing loss Transport and storage Note If you store or transport the device improperly the device may be damaged Note the information regarding tr...

Страница 9: ...into place The compressed air gun is connected 13 21 Disconnecting the compressed air gun Warning Risk of injury due to whipping compressed air hose Disconnecting the compressed air hose while the sy...

Страница 10: ...an inner diameter of 8 mm or more To connect one of the nozzles via the nozzle adapter please proceed as follows The device is switched off 1 Push the quick release lever 22 at the hose 15 of the comp...

Страница 11: ...only want to check or reduce the pressure e g in a car tyre it is not necessary to switch the device on 1 Connect the device to the mains 2 Switch the device on by setting the on off switch 2 to posit...

Страница 12: ...ng the on off switch 2 to position 0 Deflating If the existing pressure is too high or if the desired pressure was exceeded during inflation the excess air can be released To do so please proceed as f...

Страница 13: ...em to be inflated has exceeded the ambient pressure Check the item to be inflated for leaks Check the compressed air gun for proper functioning and replace it if necessary The device is running but th...

Страница 14: ...sure that no moisture enters the housing Protect electrical components from moisture Do not use any aggressive cleaning agents such as cleaning sprays solvents alcohol based or abrasive cleaners to da...

Страница 15: ...22 Guaranteed sound power level LWA 97 dB A Relevant EU directives 2005 88 EC 14 Dec 2005 2011 65 EU 01 07 2011 2014 30 EU 29 03 2014 Applied harmonised standards EN 1012 1 2010 EN 55014 1 2017 A11 20...

Страница 16: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: