17
EN
Operating manual – air cooler PAE 50
Replacing the honeycomb filter
Note
When set to air cooling mode, the device should not be
operated without the honeycomb filter, otherwise
cooling
will not work.
Note
Do not operate the device without an inserted air filter!
Without the air filter, the inside of the device will be
heavily contaminated. This could reduce the
performance and result in damage to the device.
The honeycomb filter should be replaced in case of heavy
soiling.
In standard operation, the interval for replacing the honeycomb
filter is approx. 1 year.
Allow the honeycomb filter to dry before removing it from the
device.
1. Remove the air filter and the honeycomb filter from the
device.
2. Dispose of the used honeycomb filter according to the
national regulations.
3. Insert the new honeycomb filter into the device.
4. Reinsert the air filter into the device.
Activities required after maintenance
If you want to continue using the device:
•
Reconnect the device to the mains.
If you do not intend to use the device for a considerable time:
•
Store the device according to the Storage chapter.