Operating Manual – IDE 20 D/ 30 D / 50 D / 70 D
EN
B -
3
05. Technical data
IDE 20 D
IDE 30 D
IDE 50 D
IDE 70 D
Parameter
Value
Value
Value
Value
Article number
1.430.000.060
1.430.000.065
1.430.000.070
1.430.000.075
Electrical connection
230 V
230 V
230 V
230 V
Frequency
50 Hz
50 Hz
50 Hz
50 Hz
Nominal current max.
1 A
1,5 A
1,5 A
1,8 A
Air volume
595 m³/h
720 m³/h
1100 m³/h
1300 m³/h
Fan
Axial fan
Axial fan
Axial fan
Axial fan
Nominal heat output
20 kW
30 kW
32 kW
70 kW
Temperature increase ∆T
1)
69 °C
89 °C
106 °C
122 °C
Oil consumption max.
2 l/h
3,9 l/h
5,1 l/h
7,0 l/h
Tank capacity
19 l
38 l
56 l
68 l/h
Thermostat connection
Series
Series
Series
Series
Combustion
direct
direct
direct
direct
Sound pressure level
(at distance of 1 m)
76 dB (A)
76 dB (A)
77 dB (A)
79 dB (A)
Length
740 mm
940 mm
1020 mm
1120 mm
Width
400 mm
460 mm
500 mm
574 mm
Height
550 mm
640 mm
630 mm
705
Weight
17,8 kg
22,3 kg
29 kg
40 kg
1) indicates the temperature increase. ΔT + ambient temperature = exhaust air temperature
2) optional
Fuels
The following fuels have been approved for use with
the oil heating unit IDE heating oil EL, diesel.