thermohygrometer BZ05

Remove discharged batteries from the device. Batteries
contain materials hazardous to the environment. Dispose
of the batteries according to the national regulations.

Remove the batteries from the device if you will not be
using the device for a longer period of time.

Never short-circuit the supply terminal in the battery
compartment!

Do not swallow batteries! If a battery is swallowed, it can
cause severe internal burns within 2 hours! These burns
can lead to death!

If you think batteries might have been swallowed or
otherwise entered the body, seek medical attention
immediately!

Keep new and used batteries and an open battery
compartment away from children.

Observe the storage and operating conditions (see
Technical data).

Intended use

Only use the device to measure the indoor air temperature and
humidity. Observe and comply with the technical data.
To use the device for its intended use, only use accessories and
spare parts which have been approved by Trotec.

Foreseeable misuse

Do not use the device out of doors.
Do not use the device in potentially explosive areas.

Any unauthorised changes, modifications or alterations to
the device are forbidden.

Personnel qualifications

People who use this device must:

have read and understood the instructions, especially the
Safety chapter.

Residual risks

Warning of electrical voltage

There is a risk of a short-circuit due to liquids
penetrating the housing!
Do not immerse the device and the accessories in
water. Make sure that no water or other liquids can
enter the housing.

Warning of electrical voltage

Work on the electrical components must only be
carried out by an authorised specialist company!

Warning

Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.

Warning

The device is not a toy and does not belong in the
hands of children.

Warning

Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!

Caution

Keep a sufficient distance from heat sources.

Note

To prevent damages to the device, do not expose it to
extreme temperatures, extreme humidity or moisture.

Note

Do not use abrasive cleaners or solvents to clean the
device.

Содержание BZ05

Страница 1: ...TRT BA BZ05 TC221028TTRT09 002 EN BZ05 EN OPERATING MANUAL THERMOHYGROMETER ...

Страница 2: ... BZ05 https hub trotec com id 44140 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future referen...

Страница 3: ...se the device out of doors Do not use the device in potentially explosive areas Any unauthorised changes modifications or alterations to the device are forbidden Personnel qualifications People who use this device must have read and understood the instructions especially the Safety chapter Residual risks Warning of electrical voltage There is a risk of a short circuit due to liquids penetrating th...

Страница 4: ...ature indication C F 3 Relative humidity indication 4 Feel good indication 5 MODE button 6 ADJ button 7 MEMO button 8 Hour indication 9 Minute indication 10 Battery compartment 11 RESET button 12 C F button 13 Fold out stand 14 Holder for wall mounting Technical data Parameter Value Model BZ05 Display LCD monochrome Relative humidity Measuring range 10 RH to 90 RH Accuracy 5 RH Resolution 1 Air te...

Страница 5: ...emperature complies with the values specified in the Technical data Remove the battery from the device Operation Removing the plastic strip Before first use remove the plastic strip from the battery compartment which serves to prevent contacting during storage Note Make sure that the surface of the device is dry Symbols on the display 15 17 16 19 18 21 20 23 22 No Designation 15 Alarm activated 16...

Страница 6: ...press the MODE 5 button ð The time date wake up time 1 display changes from indicating the time to the indication of the wake up time ð Both points between hour and minute display stop flashing Note If no settings are made regarding the wake up time the display changes back to the indication of the time after one minute Setting and activating the wake up time Info You can readjust a value more qui...

Страница 7: ...gens to exploit and is therefore often the ideal basis for infections If the relative humidity level is too high this will have negative impacts on the wellbeing of persons with a poor cardiovascular system in particular Besides in closed rooms that are insufficiently ventilated there is an increased risk of mould growth which actually presents another risk for your health Therefore always make su...

Страница 8: ... its life You will find collection points for free return of waste electrical and electronic equipment in your vicinity The addresses can be obtained from your municipality or local administration You can also find out about other return options that apply for many EU countries on the website https hub trotec com id 45090 Otherwise please contact an official recycling centre for electronic and ele...

Страница 9: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Отзывы: