Trotec B 5 E Скачать руководство пользователя страница 3

EN

3

humidifier B 5 E

The electrical connection must correspond to the
specifications in chapter Technical data.

Insert the mains plug into a properly secured mains
socket.

Observe the device's power input, cable length and
intended use when selecting extensions to the power
cable. Completely unroll extension cables. Avoid electrical
overload.

Before carrying out maintenance, care or repair work on
the device, remove the mains plug from the mains socket.
Hold onto the mains plug while doing so.

Switch the device off and disconnect the power cable from
the mains socket when the device is not in use.

Do not under any circumstances use the device if you
detect damages on the mains plug or power cable. 
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Defective power cables pose a serious health risk!

Make sure that the air inlet and outlet are not obstructed.

Make sure that the suction side is kept free of dirt and
loose objects.

Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.

Do not use the device when the water tank is empty.

Before filling the water tank, switch the device off and
disconnect the power cable from the mains socket. Hold
onto the mains plug while doing so.

Only transport the device in an upright position with an
emptied water tank.

Empty the water tank before transport and storage. Do not
drink the water. Health hazard!

Note that high humidity levels may enhance the growth of
biological organisms in the environment.

Make sure that objects in the surroundings of the device
do not become wet or damp. If moisture is present, the
output must be reduced. If the output cannot be reduced,
the device must only be operated in intervals. Absorbent
materials such as carpeting, curtains, sheers or tablecloths
must not become damp.

Make sure that the water in the water thank is replaced
every 3 days. Otherwise there is a risk of microorganisms
growing in the water tank which presents a health hazard
if they get into the air or water.

Intended use

Only use the device 

B 5 E

 as a mobile humidifier for the

humidification and filtration of room air, while adhering to and
following the technical data.
Intended use comprises humidifying the room air in:

living spaces

warehouses and archives

libraries

call centres and computer rooms

Improper use

The device is not intended for industrial use.

Do not place the device on wet or flooded ground.

Do not place any objects, e.g. clothing, on the device.

Do not use the device outdoors.

Any unauthorised modifications, alterations or structural
changes to the device are forbidden.

Any operation other than as described in this manual is
prohibited. Non-observance renders all claims for liability
and guarantee null and void.

Personnel qualifications

People who use this device must:

be aware of the dangers that occur when working with
electric devices in damp areas.

have read and understood the operating manual, especially
the Safety chapter.

Содержание B 5 E

Страница 1: ...TRT BA B5E TC2017 60 004 EN B 5 E EN OPERATING MANUAL HUMIDIFIER ...

Страница 2: ...e manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental...

Страница 3: ...mpty the water tank before transport and storage Do not drink the water Health hazard Note that high humidity levels may enhance the growth of biological organisms in the environment Make sure that objects in the surroundings of the device do not become wet or damp If moisture is present the output must be reduced If the output cannot be reduced the device must only be operated in intervals Absorb...

Страница 4: ...nd does not belong in the hands of children Warning Risk of suffocation Do not leave the packaging lying around Children may use it as a dangerous toy Caution If the device is knocked over water will leak from the lower part Disconnect the device from the mains to prevent damage to the device caused by dry running Note Do not operate the device without an air filter inserted into the air inlet Wit...

Страница 5: ... the water tank Do not use the power cable to drag the device Check whether the upper part is correctly positioned on the lower part Lift the device at the lower part After transporting the device observe the following Set up the device in an upright position after transport Storage Before storing the device observe the following Hold onto the mains plug while pulling the power cable out of the ma...

Страница 6: ...ure that extension cables are unrolled completely Make sure that there are no moisture sensitive objects located in the immediate vicinity of the mist nozzle since water may condense near the mist nozzle Filling the water tank The water tank should be filled before first use or when the empty water tank indication 21 lights up Note Fill the device with fresh drinking water only The water temperatu...

Страница 7: ... tank 2 8 8 Refit the mist nozzle 14 onto the water tank 2 14 9 Refit the water tank 2 into the device ð In doing so make sure that the arrow points to the front ð Please note that after inserting the water tank the water starts to run into the lower part of the device immediately 10 Set the device up in an upright and stable position ð If the device is not positioned upright the water inside the ...

Страница 8: ... 21 22 23 No Designation Description 16 Nebulizer intensity indication Indicates the selected nebulizer intensity during setting Changes dynamically to indicate ongoing operation 17 Segment display Indicates the current relative room humidity Indicates the desired relative room humidity during setting Indicates the number of hours during timer programming 18 Night mode indication Illuminated when ...

Страница 9: ... current relative room humidity is shown on the segment display 17 again ð The desired relative room humidity is set Setting the nebulizer intensity The nebulizer intensity can be set in manual humidification mode The default setting is level 2 The nebulizer intensity can be set to 3 levels level 1 low nebulizer intensity level 2 medium nebulizer intensity level 3 high nebulizer intensity 1 Press ...

Страница 10: ...ton 29 to switch over to night mode or the Auto button 30 to switch over to automatic mode Night mode The device humidifies the air constantly and regardless of the relative room humidity The timer is automatically set to 8 h The desired relative room humidity and the nebulizer intensity cannot be adjusted in this operating mode The display switches off after approx 5 s and only switches back on w...

Страница 11: ...leased ions remove pollen dust viruses and bacteria from the room air Ionization can be switched on in any operating mode 1 Press the Ionizer button 28 to switch ionization on or off ð When ionization is activated the ion indication 22 will be shown on the display Shutdown Warning of electrical voltage Do not touch the mains plug with wet or damp hands Switch off the device Hold onto the mains plu...

Страница 12: ...filter cartridge Check the valve in the water tank lid The valve must be able to move freely If necessary clean the water tank Water is leaking Check whether the device is set up in a stable and upright position Check the water level in the lower part of the device The water level might be too high and water is discharged via the overflow Check the valve in the water tank lid The valve must be abl...

Страница 13: ...ent screws X X Test run X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Clean the water tank Check air inlets and outlets for dirt and foreign objects and clean if necessary Clean the exterior Visually check the inside of the device for dirt Check the air filter for dirt and foreign objects and clean or replace if necessary ...

Страница 14: ...n Stick by Trotec to provide protection from germs in the water The SecoSan Stick prevents the reproduction of germs by means of silver ions Due to the special antimicrobial surface the silver ions are emitted to the immediate proximity of bacteria and germs This way microbial growth can be effectively prevented at the same time the water remains pure and uncontaminated The dosage of the SecoSan S...

Страница 15: ... the lid 15 firmly back onto the water tank 2 8 15 Refit the mist nozzle 14 onto the water tank 2 14 16 Refit the water tank 2 into the device In doing so make sure that the arrow points to the front Please note that after inserting the water tank the water starts to run into the inside of the device immediately Cleaning the nebulizer membrane Depending on the hardness of the drinking water used d...

Страница 16: ...ater tank 2 Unscrew the lid 15 from the water tank 2 15 8 3 Unscrew the filter cartridge 8 from the lid 15 4 Provide a vessel containing saturated saline solution 5 Place the filter cartridge into the vessel containing saline solution Make sure that the filter cartridge is completely covered by the saline solution 6 Leave the filter cartridge in the saline solution for 24 h 7 Take the filter cartr...

Страница 17: ...ompletely Do not insert a wet filter into the device 4 Reinsert the air filter into the device Activities required after maintenance If you want to continue using the device Reconnect the device to the mains If you do not intend to use the device for a considerable time Store the device according to the Storage chapter Technical annex Technical data Parameter Value Model B 5 E Nebulizer performanc...

Страница 18: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Отзывы: