8012 Trotec Speedmarker CL
SAFETY
14/10/2015
Trotec Laser GmbH
13 / 19
2.3 Safety precautions during switch-on and operation
1.
Power On/Off switch
– main switch
1
Using the main switch on the left hand side, switch the SpeedMarker CL on and off.
The key for key switch
2
can only be removed while in the 12 o'clock position. The
control circuit is activated in the 3 o'clock position and the laser can be switched on
using button 3.
Button
3
must be activated with the first switch-on.
2.
Power-On Reset switch
– button
3
Press button 3 in order to reset the voltage.
Laser radiation will not be emitted:
1. when the power is turned off and turned back on again (power supply error)
while the main switch is turned on to "position 1"
2. when the circuit for the earthing contact (hard interlock) was open and is closed
again.
The user must push button 3 in order to proceed,
i.e. laser emissions are
possible when button 3 is illuminated
Main switch
1
Key switch
2
Button
3
3. During operation, the software shows on the screen that laser radiation is being
emitted. The laser is active!
Should you still have questions regarding safety prior to starting operations, please contact
your supplier or Trotec.