TRT-BA-EKP-DS-/DH-SERIE-TC2018-42-001-EN
EN
ORIGINAL INSTRUCTIONS
EXTERNAL CONDENSATE PUMP
External condensate pump
DS/DH
s
erie
Страница 1: ...TRT BA EKP DS DH SERIE TC2018 42 001 EN EN ORIGINAL INSTRUCTIONS EXTERNAL CONDENSATE PUMP External condensate pump DS DH series...
Страница 2: ...in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and...
Страница 3: ...ontinuous operation and is suited for the following pumping media clear water slightly chlorinated or salted water Improper use Do not place the device on wet or flooded ground The device is not suita...
Страница 4: ...ndensate pump To do so either use the socket of the condensate pump 6 or directly wire the dehumidifier to the pump via the connector for direct supply 5 For direct supply the internal plug connection...
Страница 5: ...wing storage conditions dry and protected from frost and heat in an upright position where it is protected from dust and direct sunlight with a cover to protect it from invasive dust if necessary Asse...
Страница 6: ...s must only be carried out by an authorised specialist company Warning of electrical voltage Before any work on the device remove the mains plug from the mains socket Hold onto the mains plug while pu...
Страница 7: ...cable gland at the connector for direct supply 5 9 Connect the protective conductor to the housing cover 1 again 10 Then fit the housing cover 1 and secure it with the screw 9 Hose connections 1 Conn...
Страница 8: ...Store the device according to the Storage chapter Errors and faults The device has been checked for proper functioning several times during production If malfunctions occur nonetheless check the devi...
Страница 9: ...at regular intervals to remove any deposits Normal cleaning Perform this activity at least every three months For normal cleaning it is sufficient to rinse the pump with clean water e g after dehumid...
Страница 10: ...on Technical annex Technical data Parameter Value Model External condensate pump DS DH series Article number 6 100 000 019 Feed hose connection 1 2 inch Discharge hose connection 12 mm Tank volume 0 8...
Страница 11: ...eries Wiring diagram N L PE X1 1 1 X1 2 1 X1 3 1 H1 X1 2 2 M1 L X1 1 2 N S X1 3 2 PE 1 PE 2 1 2 X2 N X1 3 3 PE 1 2 3 K1 A1 12 11 14 X1 1 3 A2 22 21 24 X1 2 3 230 VAC 6 0 A X3 L PE N X4 L PE N X1 3 4 X...
Страница 12: ...ipment in your vicinity The addresses can be obtained from your municipality or local administration For further return options provided by us please refer to our website www trotec24 com The separate...