EN
9
oil-filled radiator TRH 25 E / TRH 26 E
No. Designation
Meaning
7
Temperature
symbol
Illuminated when the desired room
temperature is indicated on the
segment display.
8
Timer
symbol
Flashes when the timer is activated.
Illuminated during timer programming
9
Power
symbol
Is permanently illuminated if the on/off
switch (6) is set to
position "I" (standby operation)
10
Increase value
button
Set the desired room temperature
(15 °C to 35 °C)
11
Decrease value
button
12
Power
button
Switch the device on and off
13
Timer
button
Automatic switch-on
timer function in
increments of 1 hour (1 h to 12 h)
Automatic switch-off
timer function in
increments of 1 hour (1 h to 12 h)
Set number of hours (1 h to 12 h) for
the timer function
14
Mode
button
Select power level
I
,
II
or
III
15
High power
level III
symbol
Is illuminated if the high power level is
activated (2500 W)
16
Medium power
level II
symbol
Is illuminated if the medium power
level is activated (1500 W)
17
Low power level l
symbol
Is illuminated if the low power level is
activated (1000 W)
18 Segment display
Indication of the desired room
temperature (when switching on the
device, the temperature is preset
to 25 °C)
Indication of the number of hours
during timer programming
Switching the device on
Once you have completely installed the device as described in
the chapter Assembly and start-up, you can switch it on.
1. Set the on/off switch (6) to
I
.
ð
The
Power
symbol (9) is illuminated.
ð
An acoustic signal is emitted.
ð
The device is now in standby mode.
2. Press the
power
button (12).
ð
The preset room temperature of 25 °C is indicated on
the segment display (18).
ð
The device starts in power level
III
.
ð
The
high power level lII
symbol (15) is illuminated.
ð
The
Power
symbol (9) is illuminated.
ð
The
Temperature
symbol (7) is illuminated.
Info
The device will not be switched on until the room
temperature falls below the temperature set at the
room thermostat.
In standby mode, the device memorizes the room
temperature setting.
Setting the performance level
You can select the following power levels:
•
low power level
(capacity of 1000 W)
•
medium power level
(capacity of 1500 W)
•
high power level
(capacity of 2500 W)
1. Press the
mode
button (14) to select the desired power
level.
ð
An acoustic signal is emitted.
ð
The corresponding symbol (15, 16, 17) is illuminated.
Setting the desired room temperature
You can set the desired room temperature at any time during
operation.
1. Repeatedly press the
increase value
(10) or
decrease
value
button (11) until the desired room temperature is
shown on the segment display (18).
ð
An acoustic signal is emitted.
ð
The desired room temperature is displayed.
Info
The desired room temperature should be higher than
the current room temperature.
Setting the timer
The timer has the following modes of operation:
•
Automatic switch-on upon expiry of a preset number of
hours
•
Automatic switch-off upon expiry of a preset number of
hours
The number of hours can be between 1 and 12 and can be
adjusted in increments of 1 hour.
Note
The device must not be left unattended in a freely
accessible room with an activated timer.