convector TCH 25 E / TCH 26 E
Programming the timer
The timer has a 24-hour format. You can use it to determine
time intervals during which the device shall be switched on.
The timer has a three-step control (12):
•
Position 0: The device is switched off.
•
Position I: Continuous operation.
•
Centre position (clock symbol): The heating is switched on
and off by the programmed timer.
To program the timer, proceed as follows:
1. Turn the timer (10) clockwise until the indicator (11) points
to the current time.
2. Slide the segments (13) for the time intervals during which
the device shall be switched on outwards.
3. Set the control (12) to centre position.
ð
The timer is programmed.
Info
Please note that if the timer is activated, the device will
switch on and run unattended. Take the necessary
precautions. For instance, do not leave children
unattended near the device.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
•
Set all flip switches to
Off
. The lamps at the flip switches
turn off.
•
When using the optional timer:
Set the timer control (12) to
0
.
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
•
Allow the device to cool down completely.
•
Clean the device according to the Maintenance chapter.
•
Store the device according to the Transport and storage
chapter.
Errors and faults
Warning of electrical voltage
Tasks which require the device to be opened must
only be carried out by authorised specialist
companies or by Trotec.
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
•
Check the power connection.
•
Check the power cable and mains plug for damage. If you
notice damages, do not try to take the device back into
operation.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
•
Check the on-site fusing.
•
Check the room temperature. The room thermostat may
have switched off, because the desired room temperature
has been reached.
•
The room thermostat might be defective. Have a defective
room thermostat replaced by a specialist electrical
company.
•
Check the timer. If the control is set to
0
or if the current
time has not been selected, the device will not start.
Set the control to
I
(continuous operation).
•
Check whether the overheating protection has tripped (see
chapter Safety).
•
Wait for 10 minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.
The fan is not running:
•
Check whether the device is switched on.
•
Check the power connection.
•
Check the power cable and mains plug for damages.
•
The fan motor might be defective. Have a defective fan
motor replaced by a specialist electrical company.