Trotec 1180000090 Скачать руководство пользователя страница 9

EN

9

Ozone generator Airozon^®^ 14 ECO

7. Switch the device on and select the desired operating

mode.

ð

The cleaning cycle will probably be launched
immediately.

8. Exit the room directly after having started the device.

ð

The ozone generator will now operate until the end of
the set cleaning period. Afterwards it will switch off
automatically.

Operating parameters

The duration of the cleaning process can differ depending on
the conditions. Factors to be taken into consideration include:

Type of exposure

Intensity

Room size and temperature

Material composition of the object to be treated

Exposure time and depth up to which the material has
been affected

If an odour elimination is carried out in an unheated room which
will later be used at higher temperatures, there is a risk of
subsequent evaporation. For this reason the room temperature
should always be approx. 5 °C higher during the purification
process as compared to the later usage temperature.
The values below are to serve as a general reference for the
determination of the treatment duration:

Type of smell

Treatment duration given
in min

Room size
< 30 m³

Room size
30 – 60 m³

Car treatment

40

80

Animal, cooking and waste smells 40

80

Smell of burning / chemicals

80

120

Musty odour after water damage

80

120

Smell of burning and secondary
effects of organic substances

80 – 350

120 – 700

Amines / amides (ureas), open-
chain hydrocarbon compounds
(e.g. butyric acid)

360

720

Amino acids / proteins with
nitrogen and sulphur (vomit)

360

720

Please contact the Trotec customer service if you like to use the
device for disinfection purposes.

Switch-off

Warning

Risk of injury caused by ozone!
Have especially trained staff check the ozone
concentration before entering the room and permitting
others to access it.

Warning

Wear a respirator mask with ozone filter when you
check whether the ozone concentration has decreased
sufficiently by means of a suitable measuring device.

The device was designed to switch off automatically once the
set time has elapsed. A corresponding function was integrated
by way of a timer.
A certain waiting period must be observed between the device
switch-off and accessing the treated room.
At the end of the waiting period the room must be aired out
extensively. Open doors and windows. Take the corresponding
protective measures (see Safety chapter).

Info

Within this safety period the remaining ozone
decomposes (naturally) into divalent oxygen (O

2

).

Afterwards the ozone concentration should have fallen
to below the stipulated MAC value (maximum allowable
concentration) of 0.2 mg/m³. Ozone has an average
half-life of approx. 30 min to 60 min. The half-life
depends on various factors, e.g. on the surface to be
treated in the respective room, the temperature and
the relative humidity.

Shutdown

Warning of electrical voltage

Do not touch the mains plug with wet or damp hands.

1. Set the 

Timer

 switch to OFF.

2. Hold onto the mains plug while pulling the power cable out

of the mains socket.

3. Clean the device according to the Maintenance chapter.
4. Store the device according to the Storage chapter.

Содержание 1180000090

Страница 1: ...TRT BA AIROZON 14ECO TC2020 16 002 EN AIROZON 14 ECO EN ORIGINAL INSTRUCTIONS OZONE GENERATOR...

Страница 2: ...ore starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings...

Страница 3: ...rators The device uses ozone for air purification It is a gas that due to its oxidative characteristics can cause severe health damage if inhaled Direct exposure to and intake of ozone is toxic for hu...

Страница 4: ...mains plug with wet or damp hands Hold onto the mains plug while pulling the power cable out of the mains socket Warning Dangers can occur at the device when it is used by untrained people in an unpro...

Страница 5: ...UV radiation It is these atoms that can react with the oxygen molecules to form ozone O3 In case of a high solar irradiation ozone forms involving other air pollutants The nitrogen oxides NOx from au...

Страница 6: ...he mains plug while pulling the power cable out of the mains socket If the device was previously in use wait until the end of the calculated regeneration period see Shutdown chapter before transportin...

Страница 7: ...ground Position the device as close as possible to the centre of the room to ensure an optimum air circulation When positioning the device keep a sufficient distance to heat sources Make sure that no...

Страница 8: ...t an odour neutralization air purification Warning Risk of injury caused by inhalation of ozone The following symptoms could be indicative of poisoning or an irritation caused by ozone eye irritations...

Страница 9: ...s proteins with nitrogen and sulphur vomit 360 720 Please contact the Trotec customer service if you like to use the device for disinfection purposes Switch off Warning Risk of injury caused by ozone...

Страница 10: ...ling the power cable out of the mains socket Warning Risk of injury caused by inhalation of ozone After the device has stopped operating wait until the end of the calculated regeneration period see Sh...

Страница 11: ...aning agents Make sure that no water can enter or remain inside the housing Replacing a fuse The fuse must be replace once it is defective or no longer works correctly Please proceed as follows to rep...

Страница 12: ...V Frequency 50 Hz Max nominal current 0 8 A Max power input 180 W Ozone output 7 g h 14 0 g h Air flow rate 168 m h Sound pressure level at a distance of 3 m 45 dB A Dimensions depth x width x height...

Страница 13: ...EN 13 Ozone generator Airozon 14 ECO Circuit diagram L N E TIMER FAN Ozone Generator Power 1 FU Ozone Generator Power 2 Indicator light...

Страница 14: ...spare parts differ from those describing the positions of the components mentioned in these instructions 1 2 3 4 5 6 7 8 9 10 11 No Spare part No Spare part 1 handle 7 Ozone power supply 2 cover 8 Tim...

Страница 15: ...he contents of the declaration of conformity The signed declaration of conformity can be found at https hub trotec com id 44534 Declaration of conformity in accordance with the EC Machinery Directive...

Страница 16: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: