humidifier B 3 E / B 4 E

Check the device for leaks.

The water mist has a peculiar smell:

The device is new. Remove and rinse the water tank. Let
the open water tank air for some hours.

Check the water tank. There may be stale or dirty water in
the water tank. Rinse the water tank and fill it with clear
drinking water.

Condensate forms on the device:

The air circulation in the room is insufficient. If necessary,
reduce the nebulizer intensity and provide better air
circulation (e.g. using a fan).

The room's humidity level is quite high. This makes it
difficult for the mist to distribute and leads to water
condensing on the device. If necessary, reduce the
nebulizer intensity or switch off the device.

The device is loud or vibrates heavily:

Check whether the device is set up in a stable and upright
position.

The device still does not operate correctly after these
checks:

Please contact the customer service. If necessary, bring the
device to an authorised specialist electrical company or to
Trotec for repair.

Table of faults

The following faults can be displayed on the control panel (

6

):

Error

Meaning

The 

low water level

 LED (

20

)

flashes permanently.

The water level in the water
tank is low.

The 

low water level

 LED (

20

)

flashes three times in
succession.

The water tank is empty or not
installed correctly. The dry-run
protection has been activated

Содержание 1160000052

Страница 1: ...TRT BA B3E B4E TC210914TTRT02 001 EN B 3 E B 4 E EN OPERATING MANUAL HUMIDIFIER ...

Страница 2: ...e vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of...

Страница 3: ...eplaced every 3 days Otherwise there is a risk of microorganisms growing in the water tank which presents a health hazard if they get into the air or water Do not fill the device with water by the air inlet or outlet Do not position the device near stoves or fireplaces Avoid direct solar radiation This device contains a UV lamp Do not look into the light source for too long A damaged housing or mi...

Страница 4: ... the inside of the device will be heavily contaminated This could reduce the performance and result in damage to the device Behaviour in the event of an emergency 1 Switch the device off 2 In an emergency disconnect the device from the mains feed in Hold onto the mains plug while pulling the power cable out of the mains socket 3 Do not reconnect a defective device to the mains Information about th...

Страница 5: ...the device at the lower part Empty the water tank Empty the lower part Do not use the power cable to drag the device Check whether the upper part is correctly positioned on the lower part After transporting the device proceed as follows Set up the device in an upright position after transport Storage Before storing the device proceed as follows Hold onto the mains plug while pulling the power cabl...

Страница 6: ... are no moisture sensitive objects in the immediate vicinity of the mist nozzle since water may condense near the mist nozzle Filling the water tank The water tank 4 should be filled with clear drinking water before first use Note Fill the device with clear drinking water only The water temperature must not exceed 40 C Scented oil or other additives can damage the plastics and the nebulizer membra...

Страница 7: ...ce in the scented oil tank 8 16 3 Refit the cover with carbon filter 8 into the housing ð The cover 8 is locked audibly in the bottom section 5 Inserting the air filter Note Do not operate the device without an air filter inserted into the air inlet Without the air filter the inside of the device will be heavily contaminated This could reduce the performance and result in damage to the device Make...

Страница 8: ...outside Otherwise wipe it dry 3 Press the On off button 24 ð The nebulizer intensity LED 27 indicates the nebulizer intensity at level 1 an ð The device starts to humidify Fine water mist leaves the mist nozzle 2 Setting the nebulizer intensity The nebulizer intensity can be set to 3 levels Stage 1 Low nebulizer intensity Stage 2 Medium nebulizer intensity Stage 3 High nebulizer intensity ü The de...

Страница 9: ...ion of mist Check whether the water tank indicator light is illuminated The water tank might be empty and need refilling Check the valve in the bottom of the water tank The valve must be able to move freely Clean the water tank if required Check the float in the lower part of the device The float should be able to move freely Check the air filter for dirt Clean the air filter if required Check the...

Страница 10: ...t to distribute and leads to water condensing on the device If necessary reduce the nebulizer intensity or switch off the device The device is loud or vibrates heavily Check whether the device is set up in a stable and upright position The device still does not operate correctly after these checks Please contact the customer service If necessary bring the device to an authorised specialist electri...

Страница 11: ...run X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check for damage Visually check the inside of the device for dirt Check air inlets and outlets for dirt and foreign objects and clean if necessary Clean the exterior Cleaning the water tank Check the nebulizer membrane for dirt and clean it if necessary Check the valve unit...

Страница 12: ...ions Due to the special antimicrobial surface the silver ions are emitted to the immediate proximity of bacteria and germs This way microbial growth can be effectively prevented at the same time the water remains pure and uncontaminated The dosage of the SecoSan Stick is carried out automatically Info Clean the nebulizer membrane air outlet water tank the bottom section of the device and the water...

Страница 13: ... membrane 11 using a cotton bud 11 6 Rinse the inside of the device with clear water 7 Refit the water tank 4 as described in Cleaning the water tank Cleaning the valve unit Depending on the hardness of the drinking water used deposits may form on the valve unit over time This may impair the valve unit and cause uncontrolled water discharge from the water tank to the bottom section or result in a ...

Страница 14: ...rox 2 to 5 min 11 Remove the deposits by carefully treating the parts of the valve unit with a cotton bud 12 Mount the valve unit 10 to the water tank 4 after cleaning and tighten it in clockwise direction 4 10 13 Then mount the cover of the water filter as described in the Cleaning the water filter section 14 Refit the water tank 4 as described in Cleaning the water tank Cleaning the air filter T...

Страница 15: ... basis This tank is integrated in the cover of the carbon filter 1 Lightly push against the lower edge of the cover 8 ð The cover 8 is unlocked from the bottom section 5 2 Carefully remove the cover 8 from the device 3 Remove the carbon filter 17 from the cover 4 Remove the fleece from the scented oil tank 16 5 Clean the fleece with clear water and let it dry completely afterwards 6 Clean the scen...

Страница 16: ...crossed out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the household waste at the end of its life You will find collection points for free return of waste electrical and electronic equipment in your vicinity The addresses can be obtained from your municipality or local administration You can also find out about other return opt...

Страница 17: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Отзывы: