Trotec 1110000120 Скачать руководство пользователя страница 3

EN

3

desiccant dehumidifier TTR 160 / TTR 250

Warning

Children of less than 3 years should be kept away
unless continuously supervised.
Children aged from 3 years and less than 8 years shall
only switch on/off the appliance provided that it has
been placed or installed in its intended normal
operating position and they have been given
supervision or instruction concerning use of the
appliance in a safe way and understand the hazards
involved.
Children aged from 3 years and less than 8 years shall
not plug in, regulate and clean the appliance or
perform user maintenance.

Warning

This device is not equipped with a room temperature
controller. Do not use the device in small rooms if
persons are present who cannot leave the room
independently and who are not under constant
supervision.

Do not use the device in potentially explosive rooms or
areas and do not install it there.

Do not use the device in aggressive atmosphere.

Only put up the device in an upright, stable position on firm
ground.

Let the device dry out after a wet clean. Do not operate it
when wet.

Do not use the device with wet or damp hands.

Do not expose the device to directly squirting water.

Ensure sufficient lighting at the device.

Never insert any objects or limbs into the running device.

Do not cover the device during operation.

Do not sit on the device.

This appliance is not a toy. Keep away from children and
animals. Do not leave the device unattended during
operation.

Check accessories and connection parts for possible
damage prior to every use of the device. Do not use any
defective devices or device parts.

Ensure that all electric cables outside of the device are
protected from damage (e.g. caused by animals). Never
use the device if electric cables or the power connection
are damaged!

The electrical connection must correspond to the
specifications on the nameplate. Additionally, information
regarding the electrical connection is provided in the
technical annex.

Insert the mains plug (if any) into a properly secured mains
power socket.

Observe the device's power input, cable length and
intended use when selecting extensions to the power
cable. Completely unroll extension cables. Avoid electrical
overload.

If you do not use the device for extended periods of time,
switch the device off and disconnect it from the mains.

Before maintenance, care or repair work disconnect the
device from the mains and secure it against unauthorized
restart.

Before carrying out maintenance, care or repair work on
the device, remove the mains plug from the mains socket.
Hold onto the mains plug while doing so.

Do not under any circumstances use the device if you
detect damages on the mains plug or power cable. 
If the power cable is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Defective power cables pose a serious health risk!

When positioning the device, observe the minimum
distances from walls and other objects as well as the
storage and operating conditions specified in the technical
annex.

Make sure that the air inlet and outlet are not obstructed.

Make sure that the suction side is kept free of dirt and
loose objects.

Keep a safety distance of at least 1 m between the
device's air outlet and all combustible materials such as
textiles, curtains, beds and sofas.

Do not place the device on combustible ground.

Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.

Do not use this device near bathtubs, shower trays,
swimming pools or other water containers. Risk of electric
shock!

Allow the device to cool down before transport and/or
maintenance work.

Only transport the device in an upright position.

Do not use the device if it has been dropped or if it shows
visible signs of damage.

The device must not be positioned directly beneath a wall
socket.

Содержание 1110000120

Страница 1: ...TRT BA TTR160 TTR250 TC2021 14 004 EN TTR 160 TTR 250 EN ORIGINAL INSTRUCTIONS DESICCANT DEHUMIDIFIER ...

Страница 2: ...mation marked with this symbol helps you to carry out your tasks quickly and safely Follow the manual Information marked with this symbol indicates that the instructions must be observed You can download the current version of the instructions and the EU declaration of conformity via the following link TTR 160 https hub trotec com id 45044 TTR 250 https hub trotec com id 45045 Safety Read this man...

Страница 3: ...he nameplate Additionally information regarding the electrical connection is provided in the technical annex Insert the mains plug if any into a properly secured mains power socket Observe the device s power input cable length and intended use when selecting extensions to the power cable Completely unroll extension cables Avoid electrical overload If you do not use the device for extended periods ...

Страница 4: ...erheating and fire hazards the device must not be covered Personnel qualifications People who use this device must be aware of the dangers that occur when working with electric devices in damp areas have read and understood the instructions especially the Safety chapter Instructed person Instructed persons have been informed of the tasks they were entrusted with as well as of potential hazards res...

Страница 5: ... and storage facilities where a particularly low humidity level is required over a broad temperature range The desiccation technique enables the safe and economic operation even at low operating temperatures The desiccant dehumidifier works with a desiccant wheel rotor which is composed of layers of smooth and corrugated non woven fabric with chemically bonded silica gel Thus created is a honeycom...

Страница 6: ...points Subsequently the air current is led through a heater battery 7 and heated to approx 100 to 120 C depending on the intake temperature Simultaneously the relative humidity is extremely reduced In passing through the regeneration sector 2 the thus prepared air now again absorbs the moisture retained by the silica gel desorption Then the extremely humid regeneration air 8 is discharged to the o...

Страница 7: ...ediate neutralization with the moist exhaust air the humid air outlet should be guided away with a minimum distance of approx 1 m in case of direct intake devices Scope of delivery The scope of delivery of the device contains 1 x Dehumidifier 1 x Connection cable 1 x Instructions There are further accessories optionally available which can be obtained from the Trotec customer service Default setti...

Страница 8: ...s case the fan can be configured for permanent operation by replugging a plug contact at the integrated relay This operation may only be carried out by an electrically skilled person If required please contact the Trotec customer service Errors and faults Error Diagnosis Potential cause Remedy No dehumidi fication Dry air shows no temperature increase Rotor drive defective Check rotor drive and ha...

Страница 9: ...rained personnel or by the Trotec customer service The device is designed for long hours of operation with minimum maintenance effort Safe operation of the device requires all built in components to be checked and cleaned after 6 months at the latest or after every 4 000 operating hours as well as all damaged components to be replaced Filter change Warning Risk of injury due to fan Make sure to sw...

Страница 10: ...device Note Device may be damaged by liquid Before reinserting the air filter make sure it has dried completely Otherwise there is a risk of the fan sucking in liquid leading to a short circuit and consequential damage 4 Reinsert the air filter into the device 5 Put the cover back onto the device and tighten the screw ...

Страница 11: ...uctivity of the silica gel1 8 ammonia NH3 destruction of the silica gel structure 9 hydrofluoric acid HF destruction of the mechanical strength of the rotor material 10 aluminium chloride AlCl3 reduced productivity of the silica gel1 11 sea water reduced productivity of the silica gel1 12 steam with a high temperature destruction of the silica gel structure 13 softener clogging of the silica gel s...

Страница 12: ...nal humid air flow rate static pressure 35 m3 h 25 Pa 50 m3 h 100 Pa Intake temperature 15 C to 35 C 15 C to 35 C Ambient temperature 20 C to 40 C 20 C to 40 C Mains connection 230 V 50 60 Hz 230 V 50 60 Hz Total power consumption 0 65 kW 1 3 kW Power consumption heating 0 6 kW 1 2 kW Heating current min opt max 2 0 2 3 2 6 A 4 5 5 0 5 5 A Length approx 375 mm 410 mm Width approx 300 mm 150 mm Hei...

Страница 13: ...EN 13 desiccant dehumidifier TTR 160 TTR 250 Circuit diagram TTR 160 Circuit diagram TTR 250 ...

Страница 14: ...14 EN desiccant dehumidifier TTR 160 TTR 250 Dimensions TTR 160 Dimensions TTR 250 ...

Страница 15: ... P 1000 1064 4 Rubber tensioner P 1000 1059 18 Pressure spring P 1000 1055 5 Heating frame P 1000 3920 19 Pressure spring P 1000 1056 6 Handle P 1000 1246 20 Heating plate P 1000 1102 7 Fan P 1000 1073 21 Heating element P 1000 1182 8 Relay P 1000 0195 22 Toothed belt P 1000 1063 9 Switch P 1000 1077 23 Rotor P 1000 1035 10 Connection socket P 1000 1049 24 Needle bush P 1000 1061 11 Protective cap...

Страница 16: ... P 1000 1066 4 Rubber tensioner P 1000 1059 18 Pressure spring P 1000 1055 5 Heating frame P 1000 3932 19 Pressure spring P 1000 1056 6 Handle P 1000 1246 20 Heating plate P 1000 1103 7 Fan P 1000 1074 21 Heating element P 1000 1075 8 Relay P 1000 0195 22 Toothed belt P 1000 1065 9 Switch P 1000 1077 23 Rotor P 1000 1036 10 Connection socket P 1000 1049 24 Needle bush P 1000 1061 11 Protective cap...

Страница 17: ...quipment Declaration of conformity Declaration of conformity in accordance with the EC Machinery Directive 2006 42 EC Annex II Part 1 Section A We Trotec GmbH declare in sole responsibility that the product designated below was developed constructed and produced in compliance with the requirements of the EC Machinery Directive in the version 2006 42 EC Product model Product TTR Product type desicc...

Страница 18: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Отзывы: