Trotec 1105000010 Скачать руководство пользователя страница 2

2

EN

dehumidifier TTP 5 E / TTP 10 E

Table of contents

Notes regarding the operating manual................................. 2

Safety ..................................................................................... 2

Information about the device................................................ 4

Transport and storage........................................................... 6

Assembly and start-up.......................................................... 6

Operation ............................................................................... 7

Errors and faults.................................................................... 8

Maintenance .......................................................................... 9

Technical annex................................................................... 13

Disposal ............................................................................... 13

Notes regarding the operating manual

Symbols

Warning of electrical voltage

This symbol indicates dangers to the life and health of
persons due to electrical voltage.

Warning

This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.

Caution

This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.

Note

This signal word indicates important information 
(e.g. material damage), but does not indicate hazards.

Info

Information marked with this symbol helps you to carry
out your tasks quickly and safely.

Follow the manual

Information marked with this symbol indicates that the
operating manual must be observed.

You can download the current version of the operating manual
and the EU declaration of conformity via the following link:

TTP 5 E

https://hub.trotec.com/?id=41289

TTP 10 E

https://hub.trotec.com/?id=41290

Safety

Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use.

Warning
Read all safety warnings and all instructions.

Failure to follow the warnings and instructions may
result in electric shock, fire and/or serious injury.

Save all warnings and instructions for future
reference.

This appliance can be used by children aged 
from 8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of
experience and knowledge if they have been given
supervision or instruction concerning use of the
appliance in a safe way and understand the hazards
involved.
Children shall not play with the appliance. Cleaning and
user maintenance shall not be made by children
without supervision.

Do not use the device in potentially explosive rooms or
areas and do not install it there.

Do not use the device in aggressive atmosphere.

Only put up the device in an upright, stable position on firm
ground.

Let the device dry out after a wet clean. Do not operate it
when wet.

Do not use the device with wet or damp hands.

Do not expose the device to directly squirting water.

Do not cover the device during operation.

Do not sit on the device.

Содержание 1105000010

Страница 1: ...TRT BA TTP5E TTP10E TC220516TTRT03 005 EN TTP 5 E TTP 10 E EN OPERATING MANUAL DEHUMIDIFIER ...

Страница 2: ... TTP 5 E https hub trotec com id 41289 TTP 10 E https hub trotec com id 41290 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all wa...

Страница 3: ...ke sure that the air inlet and outlet are not obstructed Make sure that the suction side is kept free of dirt and loose objects Never insert any objects or limbs into the device Do not remove any safety signs stickers or labels from the device Keep all safety signs stickers and labels in legible condition Only transport the device in an upright position with an emptied condensation tank or drain h...

Страница 4: ...y 1 Switch the device off 2 In an emergency disconnect the device from the mains feed in Hold onto the mains plug while pulling the power cable out of the mains socket 3 Do not reconnect a defective device to the mains Information about the device Device description The device uses the principle of condensation and a Peltier element to dehumidify small rooms in a silent manner The fan sucks in dam...

Страница 5: ...e depiction TTP 5 E 6 4 1 2 3 5 TTP 10 E 2 1 3 6 8 7 9 No Designation 1 On off switch LED illuminated 2 Air inlet 3 Condensation tank 4 Power adapter 5 Mains connection 6 Air outlet 7 Transport handle 8 Air filter TTP 10 E only 9 Power cable ...

Страница 6: ...ther devices or objects on top of the device to prevent it from being damaged Assembly and start up Scope of delivery 1 x device 1 x Power adapter TTP 5 E 1 x Power cable TTP 10 E 1 x Power cable TTP 10 E 1 x manual Unpacking the device 1 Open the cardboard box and take the device out 2 Completely remove the packaging 3 Fully unwind the power cable Make sure that the power cable is not damaged and...

Страница 7: ...s inserted correctly Ensure that the condensation tank V is empty and inserted correctly Connecting the power cable power adapter TTP 5 E Plug the cable s device plug into the device s mains connection TTP 5 E Plug the power adapter or power cable into a properly fused mains socket Operation Avoid open doors and windows After being switched on the device operates fully automatically Operating elem...

Страница 8: ...wer cable and mains plug for damage Check the on site fusing Check the condensation tank for correct seating Check whether the condensation tank is full The indicator LED 10 is illuminated in orange Check the room temperature Observe the device s permissible ambient temperature according to the technical data Wait for 10 minutes before restarting the device If the device is not starting have the e...

Страница 9: ...tank and or drain hose X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign objects and clean if necessary Check air inlets and outlets for dirt and foreign objects and clean if necessary Clean the exterior Visually check the inside of the device for dirt Test run Empty and clean ...

Страница 10: ...hol based or abrasive cleaners to dampen the cloth Visual inspection of the inside of the device for dirt 1 Remove the air filter 2 Use a torch to illuminate the openings of the device 3 Check the inside of the device for dirt 4 If you see a thick layer of dust have the inside of the device cleaned by a specialist company or by Trotec 5 Put the air filter back in Cleaning the air filter The follow...

Страница 11: ...ice 4 Reinsert the air filter into the device TTP 10 E Emptying the condensation tank If the condensation tank is full the indicator LED 10 lights up orange The device switches off 1 Take the condensation tank out of the device 11 2 Remove the rubber stopper 11 from the condensation tank 3 Empty the condensation tank over a drain or sink 4 Put the rubber stopper 11 back in 5 Rinse the tank with cl...

Страница 12: ...he float is positioned correctly In doing so make sure that the condensation tank is inserted correctly for otherwise the device cannot be switched back on Activities required after maintenance If you want to continue using the device Reconnect the device to the mains If you do not intend to use the device for a considerable time Store the device according to the Transport and storage chapter ...

Страница 13: ...at this equipment must not be disposed of with the household waste at the end of its life You will find collection points for free return of waste electrical and electronic equipment in your vicinity The addresses can be obtained from your municipality or local administration You can also find out about other return options that apply for many EU countries on the website https hub trotec com id 45...

Страница 14: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Отзывы: