Страница 1: ...TRT BA TTP5E TTP10E TC220516TTRT03 005 EN TTP 5 E TTP 10 E EN OPERATING MANUAL DEHUMIDIFIER ...

Страница 2: ... TTP 5 E https hub trotec com id 41289 TTP 10 E https hub trotec com id 41290 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all wa...

Страница 3: ...ke sure that the air inlet and outlet are not obstructed Make sure that the suction side is kept free of dirt and loose objects Never insert any objects or limbs into the device Do not remove any safety signs stickers or labels from the device Keep all safety signs stickers and labels in legible condition Only transport the device in an upright position with an emptied condensation tank or drain h...

Страница 4: ...y 1 Switch the device off 2 In an emergency disconnect the device from the mains feed in Hold onto the mains plug while pulling the power cable out of the mains socket 3 Do not reconnect a defective device to the mains Information about the device Device description The device uses the principle of condensation and a Peltier element to dehumidify small rooms in a silent manner The fan sucks in dam...

Страница 5: ...e depiction TTP 5 E 6 4 1 2 3 5 TTP 10 E 2 1 3 6 8 7 9 No Designation 1 On off switch LED illuminated 2 Air inlet 3 Condensation tank 4 Power adapter 5 Mains connection 6 Air outlet 7 Transport handle 8 Air filter TTP 10 E only 9 Power cable ...

Страница 6: ...ther devices or objects on top of the device to prevent it from being damaged Assembly and start up Scope of delivery 1 x device 1 x Power adapter TTP 5 E 1 x Power cable TTP 10 E 1 x Power cable TTP 10 E 1 x manual Unpacking the device 1 Open the cardboard box and take the device out 2 Completely remove the packaging 3 Fully unwind the power cable Make sure that the power cable is not damaged and...

Страница 7: ...s inserted correctly Ensure that the condensation tank V is empty and inserted correctly Connecting the power cable power adapter TTP 5 E Plug the cable s device plug into the device s mains connection TTP 5 E Plug the power adapter or power cable into a properly fused mains socket Operation Avoid open doors and windows After being switched on the device operates fully automatically Operating elem...

Страница 8: ...wer cable and mains plug for damage Check the on site fusing Check the condensation tank for correct seating Check whether the condensation tank is full The indicator LED 10 is illuminated in orange Check the room temperature Observe the device s permissible ambient temperature according to the technical data Wait for 10 minutes before restarting the device If the device is not starting have the e...

Страница 9: ...tank and or drain hose X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign objects and clean if necessary Check air inlets and outlets for dirt and foreign objects and clean if necessary Clean the exterior Visually check the inside of the device for dirt Test run Empty and clean ...

Страница 10: ...hol based or abrasive cleaners to dampen the cloth Visual inspection of the inside of the device for dirt 1 Remove the air filter 2 Use a torch to illuminate the openings of the device 3 Check the inside of the device for dirt 4 If you see a thick layer of dust have the inside of the device cleaned by a specialist company or by Trotec 5 Put the air filter back in Cleaning the air filter The follow...

Страница 11: ...ice 4 Reinsert the air filter into the device TTP 10 E Emptying the condensation tank If the condensation tank is full the indicator LED 10 lights up orange The device switches off 1 Take the condensation tank out of the device 11 2 Remove the rubber stopper 11 from the condensation tank 3 Empty the condensation tank over a drain or sink 4 Put the rubber stopper 11 back in 5 Rinse the tank with cl...

Страница 12: ...he float is positioned correctly In doing so make sure that the condensation tank is inserted correctly for otherwise the device cannot be switched back on Activities required after maintenance If you want to continue using the device Reconnect the device to the mains If you do not intend to use the device for a considerable time Store the device according to the Transport and storage chapter ...

Страница 13: ...at this equipment must not be disposed of with the household waste at the end of its life You will find collection points for free return of waste electrical and electronic equipment in your vicinity The addresses can be obtained from your municipality or local administration You can also find out about other return options that apply for many EU countries on the website https hub trotec com id 45...

Страница 14: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...