R9T15FIRE
Page 14 of 16
Rev. D 04JAN19
CAUTION: Use a joint compound or thread tape approved for the type of gas this appliance is
intended to use on all male threads EXCEPT compression threads. Never apply thread tape of
compound to compression threads.
Beneath the Burner tray, locate the Gas/Air Mixer in the plumbing. Remove the LP Gas/Air Mixer
and replace with the Natural Gas Orifice.
LP Gas/Air Natural
Mixer Gas Orifice