BURNER TRAY AND CONTROLS 

(401100 BASE) 

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

Pressure Test Port 

   

PARTS LIST

 

   

   

   

Item No. 

   

Description  

 

   

Burner Tray, Round 18” 

Part No. 

   

R15MS300 

   

Burner Tray, Square 18” (not shown) 

R15MS301 

Blow Out Box Assembly 

R19NT108 

Burner, 6 Point Arm, 12” Diameter 

R18BA104 

Nut, 1/2” Stainless Steel 

R02NU500 

Nipple, 1/2” Stainless Steel 

R15CO106 

Pilot & Thermocouple Assembly 

R19TC100 

Igniter Assembly 

R19NT100 

1/2" x 3/8” Reducing Bushing 

R15CO108 

3/8” LP Gas/Air Mixer 

R18VL101 

10 

3/8” FPT – “TEE” 

R15CO109 

11 

1/2" MPT x 1/8” FPT Reducing Bushing 

R15CO110 

12 

13 

Solid Hex Socket Plug W/Thread Sealant 

Electrical Insulation, Silicone/Fiberglass 

R02SC443 

R19NS100 

 

 

 

Содержание 401154FP

Страница 1: ...ath and may result in property damage Read these installation operating and maintenance instructions thoroughly before installing or servicing this equipment WARNING Do not store or use gasoline or other flammable vapors or liquids in or near this or any other appliance An LP Liquefied Petroleum tank that is not connected for use shall not be stored in or near this or any other appliance If you sm...

Страница 2: ...an enclosed space such as camper tent car or home Some information listed in this manual has headings which have been highlighted In order to assist you in identify critical pieces of information They can be identified as follows WARNING Contains information critical to the safe installation and operation of the unit DANGER Contains information critical to the safety of you your personal property ...

Страница 3: ...Burning gas both Natural and LP produces fumes which can be dangerous if inhaled Always insure there is proper ventilation when using any fire products DANGER All Fire Pits are designed and intended for outdoor use only Never install or operate indoors Burning gas both Natural and LP produces very high temperatures Always insure all combustible materials are kept far enough away to prevent acciden...

Страница 4: ...on FLARED fittings Be sure all joints are tightened securely before lighting WARNING Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a qualified service person More frequent cleaning may be required as necessary It is imperative that control compartment burners and circulating air passageways of the applianc...

Страница 5: ...O T Specifications for LP Gas Cylinders or the Standard for Cylinders Spheres and Tubes for Transportation of Dangerous Goods and Commission CAN CSA B339 as applicable 2 Provided with a Listed overfilling prevention device and 3 Provided with a cylinder connection device compatible with the connection for the appliance IMPORTANT The LP Gas tank must be secured in the fire pit by placing the bottom...

Страница 6: ...th components that have the exact same ratings WARNING Before you turn on your Fire Pit for the first time you must test your connections to insure there are no leaks Gas from leaking joints can pose a serious threat to your personal property yourself and others near this Fire Pit NEVER use a lit match lighter or other sources of fire to check joints for leaks Use a gas leak detection kit availabl...

Страница 7: ... rock or glass the more risk of reducing or smothering the flame from the burner Lava Rock Only Application 1 Install your Fire Pit per instructions 2 Apply lava rock ONLY deep enough to cover ring and pan less than 2 above fire ring 3 Blow Out Box Do not cover vents with lava rock leave open Do not allow any rock to block flame opening Decorative Glass Application 1 Install your Fire Pit per inst...

Страница 8: ...press and hold the gas valve knob 4 Turn On spark igniter by depressing switch in short bursts until pilot lights 5 Once lit release switch for spark igniter while continuing to depress valve knob for 20 seconds 6 Turn knob counter clockwise left to light main burner NOTE If fails to light rotate knob to center position wait 5 minutes for gas to clear repeat Steps 3 6 If pilot goes out repeat Step...

Страница 9: ... M x 3 8 F R15CO100 6 Compression Fitting 1 8 R15CO104 7 Gas Valve R18VL100 8 Ignition Wire set of 3 12 Long R19WR100 9 Ignition Switch With Gasket R19SW100 10 Knob Black for Gas Valve R02MS102 11 Nut Retaining M1 for Gas Valve R02NU501 12 Nipple 3 8 x 1 5 R15SP101 13 Gas Plumbing Support Weldment W401100HGM 14A Spark Igniter Power Supply Cap R19NT101 14B Spark Igniter Power Supply Housing Sold as...

Страница 10: ...9NT108 3 Burner 6 Point Arm 12 Diameter R18BA104 4 Nut 1 2 Stainless Steel R02NU500 5 Nipple 1 2 Stainless Steel R15CO106 6 Pilot Thermocouple Assembly R19TC100 7 Igniter Assembly R19NT100 8 1 2 x 3 8 Reducing Bushing R15CO108 9 3 8 LP Gas Air Mixer R18VL101 10 3 8 FPT TEE R15CO109 11 1 2 MPT x 1 8 FPT Reducing Bushing R15CO110 12 13 Solid Hex Socket Plug W Thread Sealant Electrical Insulation Sil...

Страница 11: ...4 3 8 Flare x 3 8 MIPT R18CO108 5 Compression Fitting 1 8 R15CO104 6 Gas Valve R18VL100 7 Ignition Wire set of 3 12 Long R19WR100 8 Ignition Switch With Gasket R19SW100 9 Knob Black for Gas Valve R02MS102 10 Nut Retaining M1 for Gas Valve R02NU501 11 Nipple 3 8 x 1 5 R15SP101 12 Gas Plumbing Support Weldment W401442FPSGV Gas Plumbing Support Weldment W401443FPSGV 13 Spark Igniter Power Supply R19N...

Страница 12: ...n R15MS301 5 Nut 1 2 Stainless Steel R02NU500 6 Solid Hex Socket Plug W Thread Sealant R02SC443 7 1 2 x 3 8 Reducing Bushing R15CO108 8 3 8 LP Gas Air Mixer R18VL101 9 3 8 FPT TEE R15CO109 10 1 2 MPT x 1 8 FPT Reducing Bushing R15CO110 11 Screw PHP 8 x 1 2 Self Tapping SST R02SC140 12 Elbow 1 2 F x 1 2 F Galvanized R18CO117 13 Nipple 1 2 Galvanized R18CO116 14 3 8 Flare 1 2 MIPT R18CO107 15 Washer...

Страница 13: ...r assembly connection beneath the burner tray When converting from LP to Natural gas installer must remove the supplied gas hose and LP regulator and install the correct regulator for Natural gas The regulator must limit the supply as specified below Natural Gas Supply Pressure Minimum 5 0 WC water column Maximum 10 0 WC Operating Pressure Minimum 5 0 WC Maximum 7 0 WC Remove the LP Gas tank hose ...

Страница 14: ... this appliance is intended to use on all male threads EXCEPT compression threads Never apply thread tape of compound to compression threads Beneath the Burner tray locate the Gas Air Mixer in the plumbing Remove the LP Gas Air Mixer and replace with the Natural Gas Orifice LP Gas Air Natural Mixer Gas Orifice ...

Страница 15: ...ev F 10SEP14 Once your Fire Pit has been converted to Natural Gas please locate the small silver label and remove the bottom strip Place this strip over the section indicated above on the large label located on the inside door ...

Страница 16: ...e Pit has been tested and approved in accordance with ANSI Z21 97 by ICC ES Listing No PMG 1114 Tropitone Furniture Co Inc 5 Marconi Irvine Ca 92618 949 951 2010 www tropitone com 1401 Commerce Blvd Sarasota Fl 34243 Tropitone Furniture Co Inc 2014 ...