Model: 08-4049-1012
Engine Compressor Washer
04/2007 - Rev. 09
- 2 -
This product can not be modified without the written approval of Tronair, Inc. Any modifications done without
written approval voids all warranties and releases Tronair, Inc., it suppliers, distributors, employees, or financial
institutions from any liability from consequences that may occur. Only Tronair OEM replacement parts shall be
used.
1.0 GENERAL DESCRIPTION
The Engine Compressor Washer is a portable unit designed to spray either cleaning solution and/or clean
fresh water into jet and turboprop engines.
The two fluid tanks will hold 12 gallons each. The air tanks, when charged to 125 psi, provides sufficient
volume to empty both fluid tanks. The nozzle mounted on the panel may be installed on the wand to
regulate the fluid flow to the approximate rate as indicated.
2.0 OPERATION
WARNING!
1. Personal injury may result if procedures are not followed.
2. Never open fluid tank while under pressure.
3. Never pressurize air tank more than 125 psi.
CAUTION
1. Use only clean water and/or cleaning fluids approved by engine manufacturer.
2. Consult aircraft manual for correct procedure in performing engine wash.
2.1
PREPARATION & OPERATION
Follow engine manufacturer's recommendations for cleaning and rinsing engine(s). Use only engine
manufacturer's approved fluids.
2.1.1
Preparation
1. Visually inspect unit for any signs of shipping damage or missing parts.
2. Ensure supply air valve on Control Panel is in the closed (Off) position.
3. Open air bleed to depressurize solution tanks.
4. Remove solution tank lids and fill respective tank with desired amount of fluid.
5. Close solution tank lids.
6. Attach shop air to air fill valve on Control Panel and charge air tanks to 125 psi (8.6 bars)
maximum.
7. Unit is now ready for immediate use. If unit stands idle, agitate fluid before use.
2.1.2
Fluid Agitation
NOTE:
Reference to the Agitation circuit being “ON” means the Agitation Operation
(3-way) valve handle is pointing to the left (9 o’clock position), and “OFF”
means valve handle is pointing to the right (3 o’clock position). The valve
must either be in the “ON” or “OFF” position to pressurize solution tank.
1. Fully charge air supply tanks. Turn on agitation operation valve and ensure supply air
valve is in the off position (closed).
2. Open air bleed valve on top of solution tank.
3. Set regulator to desired agitation pressure (30 psi recommended).
4. Slowly open supply air valve. When suds start coming out of the air bleed valve, or
desired agitation is reached, close air bleed valve and turn off the agitation operation
valve.
Содержание 08-4049-1012
Страница 2: ......
Страница 5: ...Model 08 4049 1012 Engine Compressor Washer 04 2007 Rev 09 1 Schematic RINSE SIDE CLEAN SIDE ...
Страница 14: ......
Страница 15: ...APPENDIX I Declaration of Conformity ...
Страница 16: ......