Models: 02-0517C0140 & 02A0517C0140
5 Ton (4.5 Metric Ton)
Two Stage Jack
09/2006 - AA - Rev. OR
- 1 -
This product can not be modified without the written approval of Tronair, Inc. Any modifications done without
written approval voids all warranties and releases Tronair, Inc., it suppliers, distributors, employees, or financial
institutions from any liability from consequences that may occur.
1.0 OPERATION
1.1 OPERATING
PARAMETERS
1.
The user shall work in accordance with the Operator Manual.
2.
At no time shall personnel work under the raised load until it is secured by suitable means, i.e.
ram locknut.
3.
The employer of the operator shall provide for all necessary training and give information about
pumping and translating forces.
4.
Operate between -20
°
C and 50
°
C (-4
°
F and 122
°
F).
1.2 NUMERICAL
VALUES
•
Rated Capacity:
10,000 lbs (4,536 kg)
•
Minimum Closed Height:
17 5/8 in (44.77 cm)
•
Mechanical Extension:
7 in (17.78 cm)
•
Hydraulic Extension:
22 in (55.88 cm)
•
Maximum Height Obtainable:
46 5/8 in (118.43 cm)
•
Weight:
105 lbs (47.63 kg)
•
Pressure Relief Setting:
2,500 +250/-0 psig (172.4+17.2/-0 bas)
•
Noise level is 64 dB(A) at a distance of 120 in (304.8 cm) at an inlet pressure of 100 psi (6.9 bar)
1.3 OPERATOR
CONTROLS
1.0 Operation continued on following page.
FIGURE 7.3
−
Operator Controls