Determine where to locate the main controller. It is recommended to 

be located in an area that will remain dry and clean. The controller 

comes with a simple to use DIN type bracket.

Pull the 4 tabs outward to release the bracket from the unit, mount 

the bracket to a wall or surface.

Place the unit back on the bracket and press the 4 tabs back in to lock 

the unit in place.

*Reminder: 

The interconnecting RJ12 communication cables are 

available in different lengths, select the correct length for your 

application. The HCS-3 Hydro-X Plus Control System is supplied with 

a 4ft and 16ft cable. These interconnecting RJ12 cables are also 

available in lengths of 25ft and 50ft. Select the correct length for your 

application.

1. Mount the base panel 

on the wall with screws

2. Attach the controller 

onto the base panel

3. Lock the controller 

with the spring clips

4. Finished

04

05

CONNECTIONS

4-i

n-1 Sensor

Lighting Adapter

Lighting A

dapter

Grow Lights

Grow Lights

Quantum Sensor

Smok

e Detector

W

ater Detector

W

ater Content

Sensor

Содержание HCS-3

Страница 1: ...Quick Instruction HCS 3...

Страница 2: ...any lights as necessary unlimited numbers All of the connections between the HCS 3 and the device modules and sensors use standard RJ12 cable A maximum cable length of 1000ft 300 meters between the HC...

Страница 3: ...munication cables are available in different lengths select the correct length for your application The HCS 3 Hydro X Plus Control System is supplied with a 4ft and 16ft cable These interconnecting RJ...

Страница 4: ...your lights you must first install one of TrolMaster s Lighting Adapters into the RJ12 ports on the bottom of the controller labelled Line 1 and Line 2 TrolMaster offers several types of Lighting 1 In...

Страница 5: ...m Jan 15 2020 Flowering Light Temperature Humidity CO2 Timer History Settings 2 Grow Light Control There are 2 separate channels or light control ports that allow users to control their lighting fixtu...

Страница 6: ...kGrow brand of LEDs the Group Control function allows up to 10 separate groups of LEDs to be controlled separately with different light levels timer settings and high temp dimming levels 3 Device Modu...

Страница 7: ...e you are using T 3 T 1 OFF ON AUTO OFF ON AUTO OFF ON AUTO OFF Setting Setting Setting Setting ON AUTO T 4 T 2 Device Device Device Device Hot Start Delay Temp Device Stations T1 Setting Save Cancel...

Страница 8: ...le page to change the settings for device modules that are set up to control any equipment that needs to be controlled using a timer The user can choose from two different timer control functions Recy...

Страница 9: ...nimum Day and Night Alarm Setpoint for Temperature Humidity Light CO2 and VPD etc 3 Calibration Calibration for Temperature Humidity and CO2 sensors 4 Deadband Set Deadband Setpoints for Temperature H...

Страница 10: ...nd out the most updated version of the firmware To update the firmware press the nut icon on the lower left corner choose system reset then choose Firmware Update You may update it online if you have...

Отзывы: