25 P5644.1600 Rev A
On initial power on, the XD One is programmed to perform a set of initialisation tests which are listed
and described below. The device will perform the self-test routine every time it is switched on, with
results displayed in the form of green flashing icons for a pass result and red flashing icons when an
error is identified.
Refer to section 11.2 for sequence illumination details.
•
Sensor comms check
Ensures communications and correct functionality of the OPC sensor.
•
Device hardware check
Ensures functionality of the internal electronic hardware.
•
Device battery check
Ensures that the internal battery pack is functional and calibrated for use.
•
Data logging comms test
Ensures communications and correct functionality of the XD One internal memory storage.
•
EEPROM memory test
Ensures communications and functionality of the EEPROM is correct and that custom defined user
settings are not lost.
At any point during normal operation, the XD One can run the self-test routine to ensure system
functionality through specified user initiation.
To perform a self-test, press and hold the power button until all three function icons are blue, at this
point, release the power button and the device will initiate the self-test sequence.
Self-Test Results
After the self-test routine has been performed, the XD One will indicate the result via illuminated icon
status.
Refer to section 11.2 for Pass / Fail illumination details.
Note:
On return of a Pass result, the XD One will automatically continue with sensing operation.
On return of a Fail result, the XD One will check if the fault is recoverable and repeat the self-test. This
will take place up to a maximum of four times before the device will return a fatal error indication. In the
unlikely case of fatal error indication, it is recommended to contact the Trolex service team.
Содержание TX8060
Страница 1: ...USER MANUAL D ONE ONE LIFE PROTECT IT TX8060...
Страница 2: ......