WARNING – 

To guard against injury, basic safety precautions should be observed, including the following:

 READ AND FOLLOW ALL SAFETY INSTRUCTIONS.

 DANGER – To avoid possible electric shock, special care should be taken since water is employed in the use of this system. Unless a 
situation is encountered that is explicitly addressed by the provided maintenance and troubleshooting sections, do not attempt repairs 
yourself; refer to an authorized service facility.
 CAUTION - Do not operate with broken or faulty parts as this may result in exposure to ultraviolet radiation. Contact supplier for replacement 
parts.
Do not operate the system if it has a damaged cord or plug, or if it is malfunctioning or if it has been dropped or damaged in any manner.
 Always unplug the system, shut off water flow and release water pressure before servicing or cleaning. Never yank cord to remove from 
outlet; grasp the wall plug and pull to disconnect.
 Do not use the system for other than intended use. The use of attachments not recommended or sold by the manufacturer may cause an 
unsafe condition.
To prevent risk of electrical shock, connect this system only to a properly grounded, grounding-type power supply receptacle that is 
protected by a Ground Fault Circuit Interrupter (GFCI). Inspect performance of GFCI as per manufacturer’s suggested maintenance 
schedule. If an extension cord is used, ensure it is of a sufficient rating and accepts the plug from this system; never use an adapter.
 Visually inspect this system prior to installation. If the quartz sleeve or lamp is broken, cracked or damaged in any way, do not use. Contact 
the supplier for replacement parts.
 Keep all connections dry and off the ground. Do not touch plug with wet hands.
 The light emitted by the lamp will cause serious eye damage and burn unprotected skin. Do not plug system into an electrical outlet without 
first properly securing the lamp into the chamber. Unplug the system prior to removing the lamp from the chamber. 
 If the UV system malfunctions or fails, water must be boiled prior to consumption until the UV system is operational and the water lines have 
been shocked. System failure is indicated by the system’s audible and visual alarms or the absence of any indicator light.
 Intended for indoor use only. System must not be exposed to weather elements. In seasonal applications, chamber must be drained to 
prevent freezing.
 Installation of this system must be in accordance with local plumbing and electrical codes as well as any and all applicable regulations and 
laws.

 SAVE THESE INSTRUCTIONS.

Note: maximum pressure rating is 100 PSI (6.89 bar)

1.

2.

3.

4.
5.

6.

7.

8.

9.
10.

11.

12.

13.

14.

SAFETY INSTRUCTIONS

GROUNDING

This product must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce 
the risk of electrical shock. This system is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must 
be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

DANGER – Improper connection of the equipment-grounding conductor can result in a risk of electrocution. Check with a qualified electrician 
or service personnel if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with this system – if it will 
not fit the outlet, have a proper outlet installed by a qualified electrician. Do not use any type of adapter with this system.

GROUND FAULT CIRCUIT INTERRUPTER PROTECTION

To comply with the National Electrical Code (NFPA 70) and to provide additional protection from the risk of electric shock, this system should 
only be connected to a properly grounded, grounding-type power supply receptacle that is protected by a Ground Fault Circuit Interrupter 
(GFCI). Inspect operation of GFCI as per manufacturers suggested maintenance schedule.

EXTENSION CORDS

If an extension cord is necessary, use only 3-wire extension cords that have 3-prong grounding-type plugs and 3-pole cord connectors that 
accept the plug from this system. Use only extension cords that are intended for outdoor use. Use only extension cords having an electrical 
rating not less than the rating of the system.  A cord rated for less amperes or watts than this system rating may overheat. Exercise caution when 
arranging the cord so that it will not be tripped over or pulled. Do not use damaged extension cords. Examine extension cord before using and 
replace if damaged. Do not abuse extension cord. Keep extension cord away from heat and sharp edges. Always disconnect the extension cord 
from the receptacle before disconnecting this system from the extension cord. Never yank cord to pull plug from outlet. Always grasp the plug 
and pull to disconnect.

WARNING – To prevent risk of electrical shock, connect this system only to a properly grounded, grounding-

type power supply receptacle that is protected by a Ground Fault Circuit Interrupter. Pull plug before 

servicing or replacing lamp. Keep all connections dry and off the ground. Do not touch plug with wet hands.

WARNING – Read manual before installing or servicing this system. Only authorized personnel possessing a 

strong understanding of this system should attempt to replace lamp or service this system. 

WARNING – Do not look directly at UV lamp when it is operating. The light emitted by the lamp will cause 

serious eye damage and burn unprotected skin. 

NOTE – Maximum pressure rating is 100 PSI (6.89 bar)

Содержание TrojanUVMax G

Страница 1: ...this system you have taken the first step in ensuring safe drinking water Designed using the most advanced UV technology available today your UV system is designed to provide you with years of trouble...

Страница 2: ...INSTRUCTIONS GROUNDING This product must be grounded If it should malfunction or breakdown grounding provides a path of least resistance for electric current to reduce the risk of electrical shock Th...

Страница 3: ...Components 4 Specifications 5 Dimensions and layout 7 Installation 9 Installing the UV system 9 Disinfecting the water lines 11 Operation 14 Control panel 14 Troubleshooting 15 Low UV alarms 16 Maint...

Страница 4: ...t Part 602984 Lamp Pro10 G G part 602854 Pro20 H H part 602855 Pro30 J J part 602856 Chamber Pro10 G G part 650565 003 Pro20 H H part 650565 007 Pro30 J J part 650565 011 Power cord 120V part 602636 2...

Страница 5: ...FNPT General All Models Rated flow dose of 30 mJ cm2 up to 19 GPM 72 LPM 20 39 GPM 76 148 LPM 40 45 GPM 151 170 LPM Rated flow dose of 40 mJ cm2 10 GPM 38 LPM 20 GPM 76 LPM 30 GPM 114 LPM up to 15 GPM...

Страница 6: ...ontrol package Optional Solenoid valve Optional Optional Optional Controls Audible alarm mute button Yes Yes Yes New lamp button Yes Yes Yes Lamp age indicator Yes Yes Yes Lamp operation indicator Yes...

Страница 7: ...OPERATION INSTALLATION WARRANTY MAINTENANCE OPERATION OVERVIEW DIMENSIONS LAYOUT L Model Pro10 G G 21 4 55 cm 12 30cm 4 10cm 48 122cm 72 182cm 72 182cm 6 5 16 5cm 13 33cm Pro20 H H 30 8 78cm 12 30cm...

Страница 8: ...lTouchTM fan Removes excess heat from stagnant water in chamber during periods without water flow Sample valve Allows for verification of sampling of water immediately following UV treatment necessary...

Страница 9: ...l of the lamp and sleeve Make all necessary plumbing connections Attach chamber to wall vertically 4 1 3 2 10 Wet O ring with water then place over top end of sleeve 5 6 7 8 9 Do not touch glass with...

Страница 10: ...a Ground Fault Circuit Interrupter GFCI 4 1 16 10 4cm 1 2 1 2 Do not touch glass with bare hands Be sure to rotate lamp completely Let water flow to one faucet or other water outlet then close the ou...

Страница 11: ...ownstream of the UV system has been contaminated it is critical that these water lines be chemically disinfected Disinfection of the water lines is therefore required after initial system installation...

Страница 12: ...leach then stop the flow Repeat procedure at all water outlets Remember to include all faucets washing machines toilets outside taps and other water outlets Note You will likely run out of bleach if y...

Страница 13: ...INSTALLATION OVERVIEW WARRANTY MAINTENANCE OPERATION 19 20 Flush all water outlets until bleach can no longer be smelled at least 5 minutes Turn off solenoid valve override if so equipped 17 18 13...

Страница 14: ...ug in system again UV dose is below minimum required see Low UV Alarm section Sensor inactive due to lamp or ballast failure Solenoid valve open If equipped with solenoid Not applicable Solenoid valve...

Страница 15: ...ighten Leak detected from area of chamber Condensation of moist air on cold chamber slow accumulation O ring damaged deteriorated or incorrectly installed Sleeve bolt not tight enough Control humidity...

Страница 16: ...n the Installation section Pro and Plus Series are equipped with a unique patented sensor that is capable of self diagnosis Simply press the button located at the top of the sensor and hold until the...

Страница 17: ...quired follow the instructions below and re install the current lamp Lamp replacement The amount of UV light created by the lamp decreases over time requiring that the lamp be replaced The system will...

Страница 18: ...RVIEW WARRANTY MAINTENANCE OPERATION 4 Let the system cool for 10 minutes 3 2 6 5 1 Solenoid representative only Not on all systems Solenoid 10 7 Close after all water has drained 8 9 Pinch wireform t...

Страница 19: ...completely cleaned or if it appears scratched or cracked 13 1 2 1 12 2 1 11 Do not touch glass with bare hands 2 16 Remove sleeve Water will escape have bucket under chamber 14 Sleeve removal tool Ins...

Страница 20: ...is fully rotated until positive stop 23 1 2 Ensure sleeve bolt is fully rotated until positive stop 26 1 2 Ensure sleeve bolt is fully rotated until positive stop 21 Do not touch glass with bare hands...

Страница 21: ...CE OPERATION 31 33 If lamp was replaced Press and hold New Lamp button for 5 seconds until you hear a beep 35 Disinfect the water lines Refer to Disinfecting the Water Lines in Installation section 36...

Страница 22: ...omes equipped with one functioning and one spare 250V 2A fuse To access the fuses first unplug system and disconnect the power cord from the power supply Remove the fuse door by pushing in the tab on...

Страница 23: ...Trojan warrants original lamps sleeves and UV sensors to be free from defects in material and workmanship for a period of one 1 year from the date of purchase During this time Trojan will repair or re...

Страница 24: ...afe drinking water The system is intended to be installed on visually clear water not colored cloudy or turbid water If this system is used for the treatment of surface waters a prefilter found to be...

Отзывы: