![Trojan TR 12.8-110 Li-ion Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/trojan/tr-12-8-110-li-ion/tr-12-8-110-li-ion_user-manual_1170812009.webp)
9
U S E R ’ S
G U I D E
9
4.6
CONNECTING BATTERIES IN BANKS
You can increase capacity, voltage, or both by configuring your batteries as shown in Table 3.
NOTE: THE MAXIMUM NOMINAL BANK VOLTAGE FOR TRILLIUM BATTERIES IS 51.2 V.
(GROUP 24 & GROUP 27: 4 BATTERIES IN SERIES. U1: 2 BATTERIES IN SERIES.)
TABLE 3
SERIES CONNECTION
PARALLEL CONNECTION
SERIES/PARALLEL CONNECTION
To increase voltage, connect batteries in
series. This will not increase the system
capacity.
To increase capacity, connect batteries
in parallel. This will not increase the
system voltage.
To increase both voltage and capacity,
connect additional batteries in series and
parallel.
EX
AM
PL
E
Two Group 27, 12.8V batteries rated at 110 Ah.
Connected in series
Two Group 27, 12.8V batteries rated
at 110 Ah.
Connected in parallel
Four Group 27, 12.8V batteries rated at
110 Ah.
System Voltage: 12.8V +12.8V = 25.6V
System Capacity: 110 Ah
System Voltage: 12.8V
System Capacity: 110 Ah + 110 Ah = 220 Ah
System Voltage: 12.8V + 12.8V = 25.6V
System Capacity: 110 Ah + 110 Ah = 220 Ah
CALL TECH SUPPORT FOR ADDITIONAL CONFIGURATIONS
4.7
VENTILATION
Trillium batteries do not release gas during normal use. There are no specific ventilation requirements for Trillium
installations, although sufficient airflow should be provided to prevent excessive heat build-up.
4.8
BATTERY ORIENTATION
Batteries may be installed in any horizontal or vertical orientation except with the terminals facing downward.
Содержание TR 12.8-110 Li-ion