8-16
Setup and Registration (System Menu) > System Menu
TCP/IP Settings
-
TCP/IP
Select whether to use TCP/IP Protocol.
Value
: Off, On
IPv4 Setting
Set up TCP/IP (IPv4) to connect to the network. This setting is available when [
TCP/IP
] is set to [
On
].
DHCP
Select whether to use the DHCP (IPv4) server.
Value
: Off, On
Auto-IP
Select whether to use Auto-IP.
Value
: Off, On
IP Address
Set the IP address.
Value
: ###.###.###.###
NOTE
When DHCP is set to [
On
], this item is displayed only and cannot be entered.
Subnet Mask
Set the IP subnet mask.
Value
: ###.###.###.###
NOTE
When DHCP is set to [
On
], this item is displayed only and cannot be entered.
Default Gateway
Set the IP gateway address.
Value
: ###.###.###.###
NOTE
When DHCP is set to [
On
], this item is displayed only and cannot be entered.
DNS Server
Set DNS server (IPv4).
Value
: Auto (DHCP), Manual
NOTE
When [
Manual
] is selected, you can enter static DNS server information in the Primary and
Secondary fields provided.
IMPORTANT
After changing the setting, restart the network or turn the machine OFF and then ON.
Item
Description
Содержание P-4532DN
Страница 1: ...Operation Guide P 5532DN P 5032DN P 4532DN ...
Страница 219: ...10 5 Troubleshooting Regular Maintenance Replacing the Toner Container 1 2 ...
Страница 221: ...10 7 Troubleshooting Regular Maintenance 5 6 7 IMPORTANT Do not touch the points shown below ...
Страница 241: ...10 27 Troubleshooting Troubleshooting Duplex Unit 1 2 3 ...
Страница 243: ...10 29 Troubleshooting Troubleshooting 4 Inner Tray Inside Rear Cover 1 2 ...
Страница 245: ...10 31 Troubleshooting Troubleshooting Bulk Feeder 1 2 3 ...
Страница 246: ...10 32 Troubleshooting Troubleshooting 4 Duplex unit when Bulk Feeder is installed 1 2 3 ...
Страница 247: ...10 33 Troubleshooting Troubleshooting 4 5 6 ...
Страница 281: ......
Страница 282: ...2019 4 2TPGEEN001 TA Triumph Adler GmbH Betriebsstätte Norderstedt Ohechaussee 235 22848 Norderstedt Germany ...