TEMPERATURE ADJUSTMENT RANGE
The mixed water temperature can be adjusted
from cold through to a top limit (which can
be preset during installation – factory set
at approximately 38°C) with full anti-scald
protection throughout the range.
Adjusting the maximum temperature
override setting
(fig.11)
.
•
Remove the temperature control (bottom
of the mixer) by removing the end cap and
unscrewing the retaining screw
•
Turn the flow control to full flow.
•
Remove the temperature control and
maximum temperature stop and adjust
the temperature valve spindle until
the desired maximum temperature is
achieved - turning the spindle clockwise
will
Decrease
the maximum temperature,
turning the spindle anti-clockwise will
Increase
the maximum temperature.
•
When you are satisfied with the
temperature, turn the flow control off.
•
Refit in the reverse order with the maximum
temperature stops faces at the 2 & 10
o’clock position when viewed from above.
•
The maximum temperature stop in the
control should be positioned as close
as it can be to the 2 o’clock face of the
maximum temperature stop.
•
Once the temperature control is in place,
secure with the screw and replace the
end cap.
Fig.11
Top of the mixer
Increase
Decrease
Wall
Wall
Large
washer
Maximum
temperature
stop.