In the event of a product fault or complaint occurring, 
the following procedure should be followed:
DO NOT REMOVE THE PRODUCT

1.  Telephone Customer Service on 

01 628 6711 

or

 

01 628 6845

 

having available your details including post code, the model 
number and power rating of the product, together with the date 
of purchase and, where applicable, details of the particular fault.

2.  If required, the Customer Service Advisor will arrange for a 

qualifi ed engineer to call.

3.  All products attended to by a Triton service engineer must be 

installed in full accordance with the Triton installation guide 
applicable to the product. Every product pack contains an 
installation guide, however, they can also be downloaded free at 
www.tritonshowers.ie. 

4.  Our engineer will require local parking and if a permit is required, 

this must be available to the engineer on arrival at the call.

5.  If loft access is required for isolation or to complete a repair, 

the loft must have a fi xed access ladder and be boarded, with 
appropriate lighting from the access point to and around the 
repair area.

6.  It is essential that you or an appointed representative, who must 

be over 18 years of age, is present for the duration of the service 
engineer’s visit. If the product is in guarantee you must produce 
proof of purchase.

7.  Where a call under the terms of guarantee has been booked 

and the failure is not product related (i.e. scaling and furring, 
incorrect water pressure, pressure relief device operation or 
electrical/plumbing installation fault) a charge will be made. A 
charge will also be issued if nobody is at home when the service 
engineer calls or adequate parking/permit is not available.

8.  If the product is no longer covered by the guarantee an 
 

up-front fi xed fee will be charged before the site visit.

9.  Your receipt must be retained as proof of purchase. Should proof 

of purchase not be available on an ‘in-guarantee’ call, or should 
the service engineer fi nd that the product is no longer under 
guarantee, the engineer will charge the same fi xed price and 
will request payment prior to departing. If payment is not made 
on the day an administration charge will be added to the fi xed 
charge.

10.  If a debt is outstanding from a previous visit, or from any other 

Triton purchase, Triton reserves the right to withhold service until 
the debt has been settled.

11.  Triton takes the health, safety and wellbeing of its employees 

very seriously and expects customers to treat all staff members 
with respect. Should any employee feel threatened or receive 
abuse, either verbally or physically, Triton reserves the right to 
withhold service.

Replacement Parts Policy

In line with AMDEA guidelines, Triton retains functional spares 
for as long as there is a market for them and in most cases, well 
beyond.  Due to the vast array of product types, the life cycle of 
products can vary and therefore so can the length of time parts 
can be supplied. Spare parts can be ordered via our online spare
parts store or by telephoning Triton Customer Service Spares
Department on 

01 628 6711

. Payment should be made by

credit / debit card (excluding American Express or Diners Card).
Payment can also be made by pre-payment of a pro-forma
invoice, by cheque or postal order.

Telephone orders are based on information given during 
the call.  Before contacting Triton, please verify your 
requirements using the Information contained in the
user guide. Triton cannot accept liability for incorrect part 
identifi cation. 

TRITON STANDARD GUARANTEE

With the exception of accessories, Triton guarantee the
product against all manufacturing defects for a period of 

2 years

 (for domestic use only) from the date of purchase, 

provided that it has been installed by a competent person in 
full accordance with the fi tting instructions. 
All accessories such as shower heads, hoses and riser rails carry 

1 year

 parts only guarantee against manufacturing defects.

Any part found to be defective during this guarantee period 
we undertake to repair or replace at our option without 
charge, so long as it has been properly maintained and
operated in accordance with the operating instructions and 
has not been subject to misuse or damage. This product must 
not be taken apart, modifi ed or repaired except by a person 
authorised by Triton. This guarantee applies only to products 
installed within the Republic of Ireland and does not apply to 
products used commercially.  This guarantee does not affect 
your statutory rights.

What is not covered:

1.  Breakdown due to:  

a) 

use other than domestic use by the property 

occupants; 

b)

 wilful act or neglect; 

c) 

any malfunction resulting from the incorrect use or 

quality of electricity, gas or water or incorrect setting of 

controls; 

d) 

failure to install in accordance with this installation 

guide.

2.  Claims for missing parts once the product has been 

installed.

3.  Repair costs for damage caused by foreign objects or 

substances.

4.  Total loss of the product due to non-availability of parts.
5.  Compensation for loss of use of the product or 

consequential loss of any kind.

6.  Call out charges due to an abortive visit or where no fault 

has been found with the appliance.

7.  The cost of repair or replacement of isolating switches, 

electrical cable, fuses and/or circuit breakers or any other 

accessories installed at the same time. Replacement of the 

Pressure Relief Device that only activates when the shower 

outlet is blocked is also excluded. 

8.  The cost of routine maintenance, adjustments, overhaul 

modifi cations or loss or damage arising therefrom, 

including the cost of repairing damage, breakdown, 

malfunction caused by corrosion, furring, frost or exposure 

to freezing conditions.

9.  Call out charges where the water supply cannot be 

isolated, this includes consequential losses arising from

 

unserviceable supply valves, or inaccessible product or 

valves located in a loft space without suitable access.

For the latest Terms & Conditions please see:

   www.tritonshowers.ie

Triton Showers

Triton Road

Nuneaton

Warwickshire, CV11 4NR

Triton is a division of Norcros Group (Holdings) Limited

Earthridge International Ltd
Maynooth
Co. Kildare.

SERVICE POLICY

TRITON reserve the right to change product specifi cation without prior notice. E&OE. © TRITON SHOWERS 2019

Содержание T900pi

Страница 1: ...t in use This is a safety procedure recommended for all electrical appliances The showerhead and hose supplied with this product are a safety critical part of your shower Failure to use genuine Triton parts may cause injury and invalidate your guarantee IMPORTANT Under NO circumstances must this shower be connected directly to a mains water supply It is designed for GRAVITY FED COLD WATER systems ...

Страница 2: ...connected to any tap or fitting other than those specified This appliance must not be connected to the water mains supply and not connected by a hose set A suitable double pole isolation switch for supply disconnections must be incorporated in the fixed wiring circuit in accordance with current wiring rules See Electrical Installation section for further details Minimum inlet pressure 0 08 metres ...

Страница 3: ...gulations or any particular regulations as specified by Local Water Company or Water Undertakers and should be in accordance with BS EN 806 2 2 The supply pipe must be flushed to clear debris before connecting to the shower unit 2 3 DO NOT solder pipes or fittings within 300mm of the shower unit as heat can transfer along the pipework and damage components 2 4 DO NOT fit any form of outlet flow co...

Страница 4: ...ead is not blocked DO NOT place items such as soap or shampoo bottles on top of the unit Liquid could seep through the joint between the cover and backplate and possibly damage the sealing rubber This book contains all the necessary fitting and operating instructions for your Triton pumped electric shower Please read them carefully and keep for future reference The shower installation must be carr...

Страница 5: ... Sound Power Level db 55 INTRODUCTION IMPORTANT SAFETY INFORMATION GENERAL GUIDANCE NOTES please read SPECIFICATIONS GENERAL ADVICE TO USERS Main components 6 Electrical requirements 7 8 Water requirements 9 Siting of the shower 10 Fitting the shower to the wall 11 12 Plumbing connections 13 Electrical connections 14 Commissioning 15 16 Operating the shower 17 18 Operating functions 19 Instruction...

Страница 6: ...rmal safety cut out main 8 Terminal block 9 Can and element assembly 10 Power selector 11 Pressure switch 12 Temperature valve 13 Solenoid valve 14 Earth connection 15 Rear pipe cable entry area 16 Inlet elbow 17 Outlet pipe 18 Filter Inside cover fig 2 19 Start Stop switch Fig 2 NOTE Not all wires have been depicted for reasons of clarity 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 5 5 ...

Страница 7: ...ch off the whole installation at the mains supply and remove the correct fuse 3 The shower must be connected to its own independent electrical circuit IT MUST NOT be connected to a ring main spur socket outlet lighting circuit or cooker circuit 3 1 The electrical supply must be adequate for the loading of the unit and existing circuits 4 Check your consumer unit main fuse box has a main switch rat...

Страница 8: ... bath or shower cubicle It should be readily accessible to switch off after using the shower 7 Where shower cubicles are located in any rooms other than bathrooms all socket outlets in those rooms must be protected by a 30mA RCD 8 The current carrying capacity of the cable must be at least that of the shower circuit protection see Table B 8 1 To obtain full advantage of the power provided by the s...

Страница 9: ...e The supply pipe from the cistern should be on the opposite side to the float operated valve to prevent air being drawn into the pipe when the cistern is filling If it is intended to operate the shower in hard water areas above 200 ppm temporary hardness a scale inhibitor should be fitted Fig 5 shows a typical system layout DO NOT use jointing compounds on any pipe fittings for the installation M...

Страница 10: ... It is important that the wall surface is flat otherwise difficulty may be encountered when fitting the cover and subsequent operation of the unit may be impaired IMPORTANT Water regulations It is required that the showerhead be constrained by a fixed or sliding attachment so that it can only discharge water at a point not less than 25mm above the spill over level of the relevant bath shower tray ...

Страница 11: ...ovals If a top entry is required for the water pipe remove the top cut out in the backplate fig 8 and rotate the inlet elbow so that it points upward If a bottom entry is required for the cold water pipe then a hole will need to be cut out of the cover fig 9 and the inlet elbow rotated to face downward If entry is required from the back rotate the inlet elbow upwards and fit the supplied elbow to ...

Страница 12: ...out of square adjustment after the plumbing connections have been completed Note A temporary factory fitted locking screw is fitted to the power selector spindle fig 12 This is to make sure the spindle is held in the COLD position while the commissioning procedure is carried out DO NOT remove the locking screw before this procedure is completed Fig 10 Fig 11 IMPORTANT DO NOT TURN SELECTOR SPINDLE ...

Страница 13: ...he isolating stopvalve to the cistern Drain the cistern IMPORTANT The pipework must be brought direct from the cold water storage cistern with no other cold water draw offs between the shower and the cistern Fit the pipework to the inlet elbow Make sure the elbow collet is fully engaged with the pipe Although the pipework connection to the shower is via 15mm diameter pipework on long runs use 22mm...

Страница 14: ...minal marked N Live cable to terminal marked L IMPORTANT Fully tighten the terminal block screws and check that no cable insulation is trapped under the screws Loose connections can result in cable overheating Note The supply cable earth conductor must be sleeved The outer sheath of the supply cable must be stripped back to the minimum The supply cable must be secured either by routing through con...

Страница 15: ...tor to the COLD position fig 16 DO NOT remove the locking screw fitted to the power selector spindle fig 17 it can be removed only when the commissioning procedure has been completed Make sure the water supply is still turned on to the shower Open the bleed screw on the pump unit fig 18 by rotating one revolution When water flows from the drain pipe this indicates that any trapped air is vented an...

Страница 16: ...ooth flow of water to be obtained while air and any debris is being flushed from the shower When a smooth flow of water is obtained rotate the temperature control from 1 to 10 several times fig 21 to release any trapped air within the unit Once flushing out has been completed stop the water flow by pressing the START STOP button SWITCH OFF THE ELECTRICITY SUPPLY TO THE SHOWER AT THE ISOLATING SWIT...

Страница 17: ...ing the temperature control at this setting will only increase or decrease the force of the water from the showerhead It will not alter the water temperature Red outline symbol is the LOW setting for extra economy during hot months Temperature adjustment at this setting is via the temperature control Single red symbol is the MEDIUM setting for economy during warmer months and any temperature adjus...

Страница 18: ...ckwise towards the lower numbers will increase the water flow To increase the shower temperature Turning the temperature control clockwise towards the higher numbers will decrease the water flow Note Be certain the showering temperature is satisfactory by testing with your hand before stepping under the showerhead There will always be a time delay of a few seconds between selecting a flow rate and...

Страница 19: ...oled sufficiently power to the elements will be automatically restored to the previous setting at the time of interruption Safety cut out The unit is fitted with a non resettable over temperature safety device In the event of abnormal operation which could cause unsafe temperatures within the unit the device will disconnect the heating elements It will require a visit from a qualified engineer to ...

Страница 20: ...and wash under running water Make sure all debris etc is removed Replace by pushing the unit back into its housing until the threads engage and then turn fully clockwise until tight DO NOT OVERTIGHTEN Before replacing the cover it is strongly advised to prime the unit by opening the bleed screw until water drains from it Close the bleed screw and connect the plug to the cover Replace the cover and...

Страница 21: ...230V 84500660 6 Selector switch 82500180 microswitch wire assy 7 Connecting pipe 7052556 8 Flow valve assembly 82100300 9 Solenoid 22009120 10 Inlet pipe assembly 82800600 11 Outlet pipe 83314640 12 Filter 82800620 13 Cover assembly c w knobs button 82500270 14 Terminal block wires 82201160 Start stop switch 83305380 Pressure relief device 82800450 Ref Description Part No 1 2 3 4 14 5 6 7 8 9 10 1...

Страница 22: ...Start Stop button is pressed check the consumer unit fuse or circuit breaker or isolating switch If blown or faulty renew or reset as applicable If it fails again consult a competent electrician 1 2 1 Remove the cover and ensure the plug and socket are firmly connected 1 3 1 Have solenoid checked by a competent electrician or contact Customer Service 1 4 1 If the power neon is lit when the Start S...

Страница 23: ...filter is not blocked First isolate the electricity supply and then remove the cover 6 1 2 Check the cold water cistern is full 6 1 3 Make sure the water supply pipe is not blocked or air locked 6 1 4 Check there is no simultaneous demand from the cistern during showering 6 1 5 Reprime the unit without electricity switched on to the unit see commissioning section 7 1 1 Clean or replace blocked car...

Страница 24: ...stomer Service Spares Department on 01 628 6711 Payment should be made by credit debit card excluding American Express or Diners Card Payment can also be made by pre payment of a pro forma invoice by cheque or postal order Telephone orders are based on information given during the call Before contacting Triton please verify your requirements using the Information contained in the user guide Triton...