1.1 Pump motor thermal
overload protection
activated.
1.2 Mains electricity
supply fault.
1.3 Loose wiring
connections.
1.4 Insufficient flow to
operate flow switch.
1.5 Faulty flow switch.
1.6 Failed pump motor.
2.1 Pump motor not
running.
2.2 Pump or shower unit
frozen.
2.3 Water turned off.
2.4 No water in cold
storage cistern.
2.5 System blockage.
2.6 Blocked sprayhead
on shower unit.
2.7 Blocked filter.
3.1 Faulty flow switches.
1.1.1 Allow the pump motor to cool and
automatically reset.
1.1.2 Check the pump is adequately ventilated.
1.2.1 Blown fuse. Check supply, and renew or
reset fuse. If it fails again, contact Customer
Service.
1.2.2 Power cut? Check other appliances and if
necessary contact local Electricity Company.
1.3.1 Check all connections and secure where
necessary.
1.4.1 Check isolating valve is fully open.
1.4.2 Check head of water.
1.4.3 Ensure inlet filter is clean.
1.5.1 Replace switch. Contact Triton Customer
Service for advice.
1.6.1 Replace the pump unit. Contact Triton
Customer Service.
2.1.1 See causes 1.1, 1.2, 1.3, 1.4, 1.5, and 1.6
2.2.1 Check for evidence of freezing. Contact
Triton Customer Service for advice.
2.3.1 Check isolation valves and water supply.
2.4.1 See 2.3.1
2.5.1 Isolate supplies and inspect inlet filter,
pump outlet and sprayhead.
2.6.1 Clean the sprayhead. Refer to separate
instructions.
2.7.1 Clean filter.
3.1.1 Replace flow switches. Isolate electric
supply to pump. Contact Triton Customer
Service for advice.
FAULT FINDING
Problem/symptom Cause
Action/cure
1 Pump motor
does not operate.
2 Poor or no
water flow.
3 Pump does not
switch off.
Any maintenance or repair to the pump MUST be carried out by a suitably competent person.