Shower pump

INSTallaTION

Before installing the pump, make sure the site 
conditions have been complied with fully.
Also note the following:
• 

Pipework to precede wiring.

• 

Position the pump in a dry area, preferably 
in a linen/airing cupboard, where it must be 
well ventilated and not covered with towels 
and sheets, etc.

• 

DO NOT use with a combination cylinder 
system unless the cold water cistern has 
capacity of 225 litres (50 galls) or more.

• 

To assist in clearing air bubbles from the 
system avoid using sharp bends where 
possible. Flexible/swept fittings or formed 
pipework is recommended.

• 

Make sure that all water supplies are 
isolated before connection. Gate valves or 
full way lever valves must be fitted in the 
connections to the pump. It is also advisable 
to fit a drain off point on the lowest part of 
the system.

• 

NEVER use any form of soldered fittings on 
the shower pump as this will damage the 
unit and invalidate the guarantee.

• 

NEVER use solder within 300mm of the 
pump or expose parts to a hot torch.

• 

Make sure the mains electricity supply is 
SWITCHED OFF before making the electrical 
connections.

• 

DO NOT OPERATE THE PUMP DRY. This may 
cause damage to the seals and will invalidate 
the guarantee.

note:

 The pump motor has automatically 

resetting thermal overload protection.

warnInG!

Installation  of  the  pump  will  break 
the  earth  continuity  of  the  pipework 
installation.  It  is  important  that  the 
earth be restored by cross bonding the 
pipework, to conform with current IEE 
regulations.

SITING Of THE PUmP

The pump MUST ALWAYS be positioned 
BELOW the cold water cistern and be situated 
as close as possible to the hot water cylinder. It 
is recommended that the cold water supply is 
taken from the opposite side of the cistern to the 
float operated valve to prevent air entrapment in 
the supply.
The pump should be located as close as possible 
to the water supplies to obtain maximum 
performance and positioned below the level of 
the mixing valve if possible.
Position the pump in a suitable area and make 
sure it is accessible for any maintenance etc. that 
may be necessary.

ImporTanT:

 

make sure there is sufficient 

ventilation around the pump to cool the 
motor.

warnInG!

ThE unIT musT noT BE posITIonED 

whErE IT wILL BE suBJECT To 

FrEEZInG ConDITIons.

Содержание T22i

Страница 1: ...Installers please note these instructions are to be left with the user 2180504C February 2009 Installation and operating instructions T22i Shower pump 6479496 ...

Страница 2: ...ts 5 Siting of the pump 6 Installation 7 Commissioning 8 Spare parts 9 Fault finding 10 Guarantee Service Policy Etc Rear cover To check the product suitability for commercial and multiple installations please contact Triton s specification advisory service before installation Telephone Facsimile E mail 0844 980 0730 0844 980 0744 technical tritonshowers co uk ...

Страница 3: ...1 Pipe runs must be as short as possible and standard full flow isolating gate valves or lever valves MUST be fitted to both inlet and outlet sides of the pump as an independent means of isolating the water should maintenance or servicing be necessary 1 12 DO NOT use jointing compound on any pipe fittings use only the flexible hoses supplied to connect to the pump 1 13 It is strongly recommended t...

Страница 4: ...ETY WARNINGS a Under no circumstances must this pump be connected to a mains cold water supply Failure to comply will invalidate the guarantee b The shower pump MUST NOT be used if suspected of being frozen c The pump must be earthed d Switch off immediately at isolating switch if water ceases to flow during use e Do not operate the unit outside the guidelines laid out in site requirements f This ...

Страница 5: ...Shower pump KEY TO MAIN COMPONENTS fig 1 1 Pump 2 Connector hose X4 3 Inlet filter washer X2 4 Rubber washer X2 Fig 1 1 2 3 4 ...

Страница 6: ... both fused at 5A Gate valve Service valves Other draw offs Stopvalve Cold water cistern Pump 1 metre head Essex flange 1 2 Fig 2 Diagrammatic view not to scale warning This pump is designed to supply water to a shower only and the cold water cistern 225 litres It is advisable to check that the replenishment rate from the float operated valve meets the output requirements Both the hot and cold wat...

Страница 7: ...a person using a fixed bath or shower cannot access the pump without using tools To comply with BS6700 the hot water storage temperature should not exceed 60ºC Operation at this temperature will also reduce the rate of formation of limescale in the system The water supply must not exceed 65ºC 149ºF THE PUMP MUST NOT BE CONNECTED TO THE MAINS COLD WATER SUPPLY DO NOT connect into the rising vent pi...

Страница 8: ... electricity supply is SWITCHED OFF before making the electrical connections DO NOT OPERATE THE PUMP DRY This may cause damage to the seals and will invalidate the guarantee Note The pump motor has automatically resetting thermal overload protection WARNING Installation of the pump will break the earth continuity of the pipework installation It is important that the earth be restored by cross bond...

Страница 9: ...ot and cold feed pipes from the mixer valve to the outlet flexible push in connectors f At this stage do not connect the hot and cold water supplies from the cistern and cylinder to the inlet flexible push in connectors Wait until the commissioning procedure has been completed Note Do not overtighten the connections on the pump ports and take care to prevent any system debris from entering the pum...

Страница 10: ... the cylinder and system to fill 3 Open both isolating valves and flush through thoroughly 4 Allow water to flow to waste for two or three minutes to make sure any installation debris and air is completely flushed from the system 5 Check the system pipework for leaks 6 Close both isolating valves Remove the waste hoses and connect the cistern supply pipework and cylinder pipework to the pump inlet...

Страница 11: ...Shower pump Spare PARTS Ref Description Part No 1 Pump assembly T22IOOM 2 Hose assembly X1 83309460 3 Filter seal pack X2 of each 83309470 2 3 1 3 ...

Страница 12: ...eck other appliances and if necessary contact local Electricity Company 1 3 1 Check all connections and secure where necessary 1 4 1 Check isolating valve is fully open 1 4 2 Check head of water 1 4 3 Make sure the inlet filter is clean 1 5 1 Replace the pump unit Contact Triton Customer Service 2 1 1 See causes 1 1 1 2 1 3 1 4 1 5 and 1 6 2 2 1 Check for evidence of freezing Contact Triton Custom...

Страница 13: ...Shower pump 11 ...

Страница 14: ...Shower pump 12 ...

Страница 15: ...ling Requirements To ensure that local and national legislation is complied with Triton plc ask that you dispose of any obsolete product in an environmentally friendly manner Do not place obsolete products in a wheelie bin ...

Страница 16: ...el number and power rating of the product together with the date of purchase 2 Based on information given over the telephone a Triton Customer Service Advisor will attempt to diagnose the fault and confirm whether a site visit from a qualified service engineer is required 3 All products attended to by a Triton service engineer must be installed in full accordance with the Triton installation guide...

Отзывы: