I
nstallers
please
note
these
InstructIons
are
to
be
left
wIth
the
user
2180591B June 2008
Installation and
operating
instructions
Bezique II
electric shower
Страница 1: ...Installers please note these instructions are to be left with the user 2180591B June 2008 Installation and operating instructions Bezique II electric shower...
Страница 2: ...12 Replacing the cover 14 Operating the shower 15 Operating functions 17 Adjusting the showerhead 18 Cleaning 18 Cleaning the showerhead 19 Instructions for installers and service engineers only 20 S...
Страница 3: ...te This product is not suitable for mounting into steam rooms or steam cubicles PLUMBING The plumbing installation must comply with Water Regulations Building Regulations or any particular regulations...
Страница 4: ...the hotter the water becomes the faster the flow the cooler the water b During winter the mains water supply will be cooler than in the summer so the flow rate will vary between seasons at any one te...
Страница 5: ...y 12 Thermal cut out main 13 Earth connection 14 Pressure relief device 15 Outlet temperature limiter 16 Inlet filter 17 Trimplate Inside cover fig 2 18 Cover tags 19 Control PCB 20 Start Stop switch...
Страница 6: ...fuse way which will take the fuse or Miniature Circuit Breaker MCB necessary for the shower Fig 4 4 1 If your consumer unit has a rating below 80A or if there is no spare fuse way then the installati...
Страница 7: ...The current carrying capacity of the cable must be at least that of the shower circuit protection see Table B 8 1 To obtain full advantage of the power provided by the shower use the shortest cable r...
Страница 8: ...pressures contact the local Water Authority or consult a competent plumber During periods of high ambient temperatures it may be necessary to select a low power setting to achieve your preferred showe...
Страница 9: ...hin a bath basin or shower tray then a double check valve or similar must be fitted in the supply pipework to prevent back flow Pressure relief safety device A pressure relief device PRD is designed i...
Страница 10: ...a feed pipe from the rear or bottom the centre of the inlet valve to the wall surface is 20 mm fig 11 Note If entry is from the rear the nut of the compression fitting will be partially behind the su...
Страница 11: ...n the screws at this stage as the fixing holes are elongated to allow for out of square adjustment after the plumbing connections have been completed Note If replacing an older model shower unit which...
Страница 12: ...to clear the debris to waste Procedure Turn off water supply either at the mains stopvalve or the isolating stopvalve Connect the mains water supply to the inlet of the shower via 15 mm copper stainl...
Страница 13: ...cable earth conductor must be sleeved The outer sheath of the supply cable must be stripped back to the minimum The supply cable must be secured either by routing through conduit or in trunking or by...
Страница 14: ...with the three retaining screws Fit the flexible hose to the shower outlet making sure the outlet of the hose is directed to waste Check the supplied sealing washer is in place Do not attach the show...
Страница 15: ...g 7 and lift the cover from the backplate Attached to the display PCB inside the cover is a 10 way ribbon cable The ribbon cable connector must be plugged into the socket located at the right of the p...
Страница 16: ...ide pockets on the backplate and make sure the wires are not trapped Guide the cover into position so that the knob spindle locates correctly minor adjustment may be necessary to align the knob and sp...
Страница 17: ...rature adjustment at this setting is via the temperature control The centre button red symbol is an economy setting for using less energy when the ambient mains water temperature is high during hot mo...
Страница 18: ...by lower numbers To increase the shower temperature Turn the temperature control clockwise This will decrease the flow of water through the shower therefore increasing the water temperature and is ind...
Страница 19: ...is switched off to the elements Water will continue to flow for a few seconds flushing out any remaining hot water This makes sure the next immediate user will not receive a slug of hot water if stan...
Страница 20: ...icing switch off both the electricity supply and water supply at the mains The inlet filter is situated at the bottom of the inlet pipe fig 24 To gain access to the filter remove the trimplate and the...
Страница 21: ...mbly P12120801 5 Thermal cut out 22011180 6 Pressure relief device PRD 82800450 7 Outlet pipe assembly S12711003 8 Inlet assembly S12721002 9 Trimplate white 7053372 grey 7053534 10 Cover assembly whi...
Страница 22: ...2 1 Check if stop taps are fully open Check if blockage in inlet filter 2 3 1 Switch to economy power setting and readjust flow rate to give required temperature 3 1 1 See Water too hot causes 2 1 2...
Страница 23: ...suitably qualified electrician or contact Customer Service 5 1 1 Wait until the water pressure resumes to normal Low pressure indicator extinguishes 6 1 1 Clean sprayplate and then fit a new PRD 6 2...
Страница 24: ...l number and power rating of the product together with the date of purchase 2 Based on information given over the telephone a Triton Customer Service Advisor will attempt to diagnose the fault and con...