In the event of a product fault or complaint occurring, 
the following procedure should be followed:
DO NOT REMOVE THE PRODUCT

1.  Telephone Customer Experience on 

024 7637 2222

 having 

available your details including post code, the model number 
and power rating of the product, together with the date of 
purchase and, where applicable, details of the particular fault.

2.  If required, the Customer Experience Advisor will arrange for a 

qualifi ed engineer to call.

3.  All products attended to by a Triton service engineer must be 

installed in full accordance with the Triton installation guide 
applicable to the product. (Every product pack contains an 
installation guide, however, they can also be downloaded free at 
www.tritonshowers.co.uk). 

4.  Our engineer will require local parking and if a permit is required, 

this must be available to the engineer on arrival at the call.

5.  If loft access is required for isolation or to complete a repair, 

the loft must have a fi xed access ladder and be boarded, with 
appropriate lighting from the access point to and around the 
repair area.

6.  It is essential that you or an appointed representative (who must 

be over 18 years of age) is present for the duration of the service 
engineer’s visit. If the product is in guarantee you must produce 
proof of purchase.

7.  Where a call under the terms of guarantee has been booked 

and the failure is not product related (i.e. scaling and furring, 
incorrect water pressure, pressure relief device operation or 
electrical/plumbing installation fault) a charge will be made. A 
charge will also be issued if nobody is at the property when the 
service engineer calls or adequate parking/permit is not available.

8.  If the product is no longer covered by the guarantee an 
 

up-front fi xed fee will be charged before the site visit.

9.  Your receipt must be retained as proof of purchase. Should proof 

of purchase not be available on an ‘in-guarantee’ call, or should 
the service engineer fi nd that the product is no longer under 
guarantee, the engineer will charge the same fi xed price and 
will request paument prior to departing. If payment is not made 
on the day an administration charge will be added to the fi xed 
charge.

10.  If a debt is outstanding from a previous visit, or from any other 

Triton purchase, Triton reserves the right to withhold service until 
the debt has been settled.

11.  Triton takes the health, safety and wellbeing of its employees 

very seriously and expects customers to treat all staff members 
with respect. Should any employee feel threatened or receive 
abuse, either verbally or physically, Triton reserves the right to 
withhold service.

Replacement Parts Policy

In line with AMDEA guidelines, Triton retains functional spares 
for as long as there is a market for them and in most cases, well 
beyond.  Due to the vast array of product types, the life cycle of 
products can vary and therefore so can the length of time parts 
can be supplied. Spare parts can be ordered via our online spare
parts store or by telephoning  our Triton Customer Experience
team on 

024 7637 2222

. Payment should be made by

credit / debit card (excluding American Express or Diners Card).
Payment can also be made by pre-payment of a pro-forma
invoice, by cheque or postal order.

Telephone orders are based on information given during 
the call.  Before contacting Triton, please verify your 
requirements using the Information contained in the
user guide. Triton cannot accept liability for incorrect part 
identifi cation. 

TRITON STANDARD GUARANTEE

With the exception of accessories, Triton guarantee the
product against all manufacturing defects for a period of 

5 years

 for use in a domestic environment from the date of 

purchase, provided that it has been installed by a competent 
person in full accordance with the fi tting instructions. 
All accessories such as shower heads, hoses and riser rails carry 

1 year

 parts only guarantee against manufacturing defects.

Any part found to be defective during this guarantee period 
we undertake to repair or replace at our option without 
charge, so long as it has been properly maintained and
operated in accordance with the instructions and has not 
been subject to misuse or damage or the effects of limescale 
build up. This product must not be taken apart, modifi ed 
or repaired except by a person authorised by Triton (this 
guarantee applies only to products installed within the United 
Kingdom and does not apply to products used expressly for 
commercial gain, unless this use has been specifi ed by Triton).  
This guarantee does not affect your statutory rights.

What is not covered:

1.  Breakdown due to:  

 

a) 

use other than domestic use by the property 

occupants; 

b)

 wilful act or neglect; 

c) 

any malfunction resulting from the incorrect use or 

quality of electricity, gas or water or incorrect setting of 

controls; 

d) 

failure to install in accordance with this installation 

guide.

2.  Claims for missing parts once the product has been 

installed.

3.  Repair costs for damage caused by foreign objects or 

substances.

4.  Total loss of the product due to non-availability of parts.
5.  Compensation for loss of use of the product or 

consequential loss of any kind.

6.  Call out charges due to an abortive visit or where no fault 

has been found with the appliance.

7.  The cost of repair or replacement of isolating switches, 

electrical cable, fuses and/or circuit breakers or any other 

accessories installed at the same time. Replacement of the 

Pressure Relief Device that only activates when the shower 

outlet is blocked is also excluded. 

8.  The cost of routine maintenance, adjustments, overhaul 

modifi cations or loss or damage arising therefrom, 

including the cost of repairing damage, breakdown, 

malfunction caused by corrosion, furring, frost or exposure 

to freezing conditions.

9.  Call out charges where the water supply cannot be 

isolated, this includes consequential losses arising from

 

unserviceable supply valves, or inaccessible proudct or 

valves located in a loft space without suitable access.

For the latest Terms & Conditions please see:

www.tritonshowers.co.uk/terms

UK SERVICE POLICY

Triton Showers
Triton Road
Nuneaton
Warwickshire, CV11 4NR

Triton is a division of Norcros Group (Holdings) Limited

Customer Experience: 024 7637 2222

Trade Installer Hotline: 024 7637 8344

www.tritonshowers.co.uk

E-mail: [email protected]

E-mail: [email protected]

Triton reserve the right to change product specifi cation without prior notice. E&OE. © TRITON SHOWERS 2020

Содержание ASANA MINI

Страница 1: ...OF THE BOX ALTERNATIVELY REGISTER BY TEL 024 7637 8321 INSTALLATION AND OPERATING INSTRUCTIONS Please read this book thoroughly and familiarise yourself with all instructions before commencing install...

Страница 2: ...AK TESTING 10 COMMISSIONING 11 ADJUSTING THE MAXIMUM TEMPERATURE SETTING 12 OPERATING THE SHOWER 12 APPROVALS FLOW RATES 13 MAINTENANCE 14 CLEANING THE FILTERS 14 SPARE PARTS 15 FAULT FINDING 16 17 GU...

Страница 3: ...thermostatic mixer shower 1 1 2 3 4 5 6 7 Fig 1 Main components MAIN COMPONENTS Ref Description 1 Control knob 5 Mounting plate 2 Mixer shower valve 6 Inlet nut and olive X2 3 Blanking plug 7 Wall tr...

Страница 4: ...mini exposed sequential thermostatic mixer shower 2 60mm 135mm 36mm G1 2 102mm 150mm 200mm DIMENSIONS All dimensions regarding the product and installation are approximate...

Страница 5: ...ld mains supply pipework can provide nominally equal pressures at the mixer shower Water Minimum Flow Rate For best performance within the specified running pressure range a minimum flow of 8 litres p...

Страница 6: ...ebris is not flushed through before fitting Commercial Applications Triton recommends for all commercial applications that easily accessible in line filters are used to aid maintenance Hard Water Area...

Страница 7: ...a pump to boost pressures as shown please refer to the pump installation guide to establish the minimum head requirements for automatic operation of the pump Hot water cylinder Cold supply Hot supply...

Страница 8: ...r For systems with no cold water take off after the appliance reducing valve it will be necessary to fit an additional drop tight pressure reducing valve when the mains pressure is over 5 bar The drop...

Страница 9: ...exceed 5 bar running An expansion vessel MUST be fitted and regularly maintained to ensure the unit is not damaged by excess pressures This may already be installed externally or internally within the...

Страница 10: ...of the user The accessories shower head riser rail and or fixed shower head can be positioned above or to either side of the shower fig 7 Supply Pipework Complete the pipework to the shower area havi...

Страница 11: ...r other means of sealing IMPORTANT Make sure that all supply pipework has been flushed through before fitting the mixer shower fig 11 Connect the hot water supply to the inlet marked HOT H or red oran...

Страница 12: ...out as follows with the mixer blend temperature set at 38 C isolate the cold water supply The outlet flow rate will reduce to a safe level Recommended Outlet Temperatures The BuildCert TMV scheme reco...

Страница 13: ...l until your desired maximum showering temperature is reached The mixer has a temperature stop to prevent accidental rotation to higher temperatures This is adjustable to provide a maximum temperature...

Страница 14: ...the flat edge of the maximum temperature stop as possible fig 16 When you are satisfied with the temperature turn the shower off OPERATING THE SHOWER To start the shower turn the on off temperature co...

Страница 15: ...lve has the following approval WRAS Conditions for test Inlet temperatures comply with EN1111 requirements Outlet Temperatures 38 C Flow Control open Open outlet No hose or shower head connected Flow...

Страница 16: ...cold supplies under unequal pressure conditions They are designed for long life with no maintenance NOTE The NRV s will only operate in one direction water should be able to flow into the unit from th...

Страница 17: ...o purchase a genuine Triton spare part for your product please visit www tritonshowers co uk spares for product codes and prices Alternatively please call our Customer Experience team on 024 7637 2222...

Страница 18: ...demand from the mains supply 2 Water too cold 2 1 Temperature control incorrectly commissioned 2 1 1 Refer to commissioning section 2 2 Not enough hot water flowing through shower 2 2 1 Reposition th...

Страница 19: ...head blocked 4 4 1 Clean the shower head 4 5 System not capable of supplying multiple outlets at the same time 4 5 1 Make sure stop or service valve is fully open 4 5 2 Check if there is sufficient wa...

Страница 20: ...ners Card Payment can also be made by pre payment of a pro forma invoice by cheque or postal order Telephone orders are based on information given during the call Before contacting Triton please verif...

Отзывы: