background image

2181403E

 - June 2021

INSTALLATION AND OPERATING INSTRUCTIONS 

Please read this book thoroughly and familiarise yourself with all instructions before commencing 

installation and keep it for future reference. 
The mixer shower installation 

MUST

 be carried out by a suitably qualified person, 

in the sequence 

of this instruction book. 

IMPORTANT SAFETY ADVICE

Failure to use genuine Triton parts may cause 

injury and invalidate your guarantee.

FOR YOUR SERVICE REFERENCE

NOTE DOWN THE PRODUCT CODE BELOW

(FROM THE FRONT OR TOP OF THE BOX)

ALTERNATIVELY REGISTER BY TEL: 024 7637 8321

REGISTER ONLINE

ENTER A PRIZE DRAW

WIN

£100

LOVE2SHOP VOUCHERS

VISIT OUR WEBSITE TODAY

TRITONSHOWERS.CO.UK/REGISTER

PRODUCT REGISTRATION IS ONLY AVAILABLE

TO UNITS PURCHASED & INSTALLED IN THE UK

BAR MIXER

with diver ter

Содержание 2181403E

Страница 1: ...quence of this instruction book IMPORTANT SAFETY ADVICE Failure to use genuine Triton parts may cause injury and invalidate your guarantee FOR YOUR SERVICE REFERENCE NOTE DOWN THE PRODUCT CODE BELOW F...

Страница 2: ...ge MAIN COMPONENTS 1 DIMENSIONS 2 3 INTRODUCTION 4 5 TYPICAL DOMESTIC INSTALLATIONS 6 7 SITING OF THE SHOWER 8 PREPARING THE MIXER VALVE 8 INSTALLING THE BAR MIXER BRACKET 8 FITTING THE BAR MIXER 8 11...

Страница 3: ...er shower 1 A B C D MAIN COMPONENTS E A Thermostatic mixer valve B Riser pipe C Push Fit Bracket D Wall Bracket E Fixed head pipe F Slider G Hose not shown H Handset not shown I Fixed shower head not...

Страница 4: ...Bar mixer shower 2 DIMENSIONS 150 266 96 111 131 45...

Страница 5: ...mixer shower 3 IMPORTANT All dimensions listed in this fitting book regarding the product and installation are approximate Consideration must be given for the adequate ceiling space 400 55 75mm 1127...

Страница 6: ...ent to meet all normal requirements and will minimise the effects of scale in hard water areas Pressure Reducing Valve On sites where the running pressure is above 5 bar the use of a suitably sized pr...

Страница 7: ...stem of debris and check for leaks before connecting to the mixer Commercial Applications For commercial applications in line filters are recommended Hard Water Areas a If it is intended to operate th...

Страница 8: ...ly pressures exceed 5 bar running An expansion vessel MAY be fitted and regularly maintained to prevent the shower being damaged by excess pressures This may already be installed within the boiler che...

Страница 9: ...cing valve must be set at the same value as the unvented package pressure reducing valve Note An additional expansion vessel may be required if a second pressure reducing valve is installed This does...

Страница 10: ...ng to a laminate cubicle or panel SITING OF THE SHOWER AND ACCESSORIES Refer to fig 5 for correct siting of the shower The shower should be positioned as detailed with all controls within comfortable...

Страница 11: ...face of the valve fig 7 Once the diverter has been fitted and faces forward fully tighten the small retaining grub screw located at the rear of the diverter assembly fig 8 FITTING THE MIXER SHOWER Off...

Страница 12: ...ng sure the bracket engages the hexagonal fitting and the O ring is in place fig 11 Using a suitable screwdriver tighten the retaining screw to secure the rail into the support Screw the bottom part o...

Страница 13: ...the bracket Tighten the diverter collar FITTING THE HOSE AND SHOWER HEAD Screw one end of the flexible hose to the bottom outlet connector on the diverter valve making sure that the sealing washer is...

Страница 14: ...ixer rotate the on off flow control fig 16 TEMPERATURE CONTROL right hand side To adjust the water temperature rotate the temperature control clockwise for cool or anti clockwise for hot fig 17 To ove...

Страница 15: ...their design temperature and pressures and are within the requirements stated in the site requirements Make sure the temperature control right hand side is at the maximum temperature setting Allow the...

Страница 16: ...of 41 C for showers The mixed water temperatures must never exceed 46 C The British Burns Association recommends 37 C to 37 5 C as a comfortable bathing temperature for children WARNINGS Exposed meta...

Страница 17: ...he valve will depend mainly on the water supply condition Experience of local conditions will dictate the intervals for inspection and in service testing guidance has been given below which can be adj...

Страница 18: ...17 0 19 5 22 0 Pressure bar 0 1 0 2 0 3 0 4 0 5 1 0 2 0 3 0 4 0 5 0 Conditions for test Inlet temperatures comply with EN1111 requirements Outlet temperature 38C Flow control fully open Open outlet No...

Страница 19: ...2 5 Hot water supply blocked or restricted 2 6 Flow regulator not fitted HP systems only 3 1 Flow regulators not fitted 1 1 1 Refer to the Commissioning section 1 2 1 Reposition temperature control k...

Страница 20: ...y 4 2 1 Inspect the inlet filters Clean if necessary 4 3 1 Turn off the shower and consult a suitably competent plumber 4 4 1 Clean shower head 4 5 1 Reduce the simultaneous demand 4 5 2 Make sure sto...

Страница 21: ...Bar mixer shower 19...

Страница 22: ...Bar mixer shower 20...

Страница 23: ...Bar mixer shower 21...

Страница 24: ...ent of a pro forma invoice by cheque or postal order Telephone orders are based on information given during the call Before contacting Triton please verify your requirements using the Information cont...