Triton Blue WALLYOK12Z Скачать руководство пользователя страница 26

                                                                                                                                                                      XM1115-V1.0.0-NR 

25

160-179 

Internal program 4 (secne25~32 of EEPROM) 

180-199 

Internal program 5 (secne33~40 of EEPROM) 

200-219 

Internal program 6 (secne41~48 of EEPROM) 

220-239 

Internal program 7 (secne49~56 of EEPROM) 

240-255 

Music Control (secne of Program 1) 

 
 

 
 

10. ERROR MESSAGE 

When you turn on the fixture, it will make a reset at first. The display may show“Err channel is 

XX”   while there are problems with one or more channels. “XX” stands for channel 1, 2, 3, 4, 5, 

6 who has the testing sensor for positioning. For example, when the display shows “Err channel is 

Red LED -all arrays”, it means there is some error in channel 1. If there are some errors on 

channel 5, channel 6 at the same time, you may see the error message, “Err channel is Pan 

movement”, “Err channel is Tilt movement” ,flash repeated for 2 times, and then the fixture will 

generate a second reset. If the fixture remain error message after performing reset more than 2 

times, only the channels which have errors can not work properly, others can work as usual. 

Please contact with dealer or manufacturer for service, self repair is not allowed. 

 

PAN- movement Er 

(PAN-yoke movement error) This message will appear after the reset of the fixture if the yoke’s 
magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the stepping-motor is 
defective (or its driving IC on the main PCB). The PAN-

 

movement is not located in the default 

position after the reset.

 

 
TILT- movement Er 

(TILT-head movement error) This message will appear after the reset of the fixture if the head’s 
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepping-motor 
is defective (or its driving IC on the main PCB). The TILT-

 

movement is not located in the default 

position after the reset. 
 
 
 

11. CLEANING AND MAINTENANCE 

The following points have to be considered during the inspection: 

1) All screws for installing the devices or parts of the device have to be tightly connected and 

must not be corroded. 

2) There must not be any deformations on the housing, color lenses, fixations and installation 

spots (ceiling, suspension, trussing). 

3) Mechanically moved parts must not show any traces of wearing and must not rotate with   

unbalances. 

4) The electric power supply cables must not show any damage, material fatigue or sediments.   

Further instructions depending on the installation spot and usage have to be adhered by a skilled 

installer and any safety problems have to be removed. 

 

 

In order to make the lights in good condition and extend the life time, we suggest a regular 

cleaning to the lights.

 

Содержание WALLYOK12Z

Страница 1: ...PROFESSIONAL MOVING HEAD USER MANUAL WALLYOK12Z KEEP THIS MANUAL FOR FUTURE NEEDS...

Страница 2: ...8 2 1 Time information 12 8 2 2 Temperature Info 14 8 2 3 Software Ver 14 8 3 PERSONALITY 14 8 3 1 Status Settings 14 8 3 2 Service Setting 16 8 3 3 Fans Control 17 8 3 4 Display Setting 17 8 3 5 Tem...

Страница 3: ...al Please check carefully that there is no damage caused by transportation Should there be any consult your dealer and don t install this device 1 Features 12 x 10W high power LEDs Extremely Long Life...

Страница 4: ...user manual are not subject to warranty The dealer will not accept liability for any resulting defects or problems If the device has been exposed to temperature changes due to environmental changes d...

Страница 5: ...it shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard Please be aware that damages caused by manual modifications to the d...

Страница 6: ...d in a way that it can hold 10 times the weight for 1 hour without any harming deformation The installation must always be secured with a secondary safety attachment e g an appropriate safety rope Nev...

Страница 7: ...lder into the respective holes on the bottom of the device Tighten the quick lock fasteners fully clockwise c Install the second Omega holder d Pull the safety rope through the holes on the bottom of...

Страница 8: ...XM1115 V1 0 0 NR 7 Dimensional Drawings...

Страница 9: ...of the installation material being used and periodic safety inspection of all installation material and the fixture If you lack these qualifications do not attempt the installation yourself Improper...

Страница 10: ...ch the fixture starts to listen to the digital control information sent out from the DMX controller The allocation of this starting address is achieved by setting the correct number on the display loc...

Страница 11: ...e display will automatically switch off about 1 minute from last button press Function Set Dmx Address Dmx Value Slave Mode Auto Program Sound Control A001 AXXX ALL Slave1 Slave2 Slave3 Master Alone M...

Страница 12: ...d right position User Mode Standard Mode Basic Mode Extended Mode User Mode A User Mode B User Mode C User s mode to change channel numbers User Mode Set Edit User ModeA Edit User ModeB Edit User Mode...

Страница 13: ...ps under Edit program You can edit the individual scenes under Edit scenes With this function you can run the individual scenes either automatically i e with the adjusted Step Time 1 Access the main m...

Страница 14: ...splayed Press ENTER the display will show Information Tap the Up Down button until the display will show Time Information Press ENTER the display will show Time Information 2 Press Up Down the display...

Страница 15: ...displayed Press ENTER the display will show Information 2 Press Up Down the display will show Software Ver 3 Press ENTER the display will show Software Ver 4 The display show Ver x x 5 Press ENTER to...

Страница 16: ...will show Status settings 2 Press Up Down the display will show Tilt Reverse 3 Press ENTER the display will show Tilt Reverse 4 The display show OFF Press Up Down the display will show ON 5 Press ENT...

Страница 17: ...will show Mic Sensitivity 3 Press ENTER the display will show Mic Sensitivity 4 The display show 70 Press Up Down the display will show 0 99 5 Press ENTER to confirm or press MODE ESC to return to the...

Страница 18: ...elect the desired shut off time The default is 5 minute Display Reverse With this function you can the entire display to be flipped by 180 to allow for better view when the fixture is hung from truss...

Страница 19: ...Temperature C F 4 The display show Celsius Press Up Down the display will show Fahrenheit 5 Press ENTER to confirm or press MODE ESC to return to the main menu 8 3 6 Initial Status With this function...

Страница 20: ...ol With this function you can adjust the lamp more easily All effects will be canceled the shutter opens and the dimmer intensity will be set to 100 With the individual functions you can focus the lig...

Страница 21: ...our DMX controller to the moving head Adjust the desired scene numbers via the encoder from to When you call up the scenes at your controller they will automatically be transmitted to the moving head...

Страница 22: ...ess the Enter button to confirm Press the MODE ESC button in order to return to the main menu 4 Program selection for Edit Program Select Edit program by turning the encoder Press the Enter button to...

Страница 23: ...e control of Pan movement TILT Movement 8bit 6 6 3 0 255 Tilt Movement Tilt Fine 16bit 20 4 0 255 Fine control of Tilt movement Speed Pan Tilt movement 0 225 max to min speed 226 235 blackout by movem...

Страница 24: ...lack 255 100 Red Green LED array 3 21 0 255 Green 0 Black 255 100 Green Blue LED array 3 22 0 255 Blue 0 Black 255 100 Blue White LED array 3 23 0 255 White 0 Black 255 100 White Shutter strobe 0 31 L...

Страница 25: ...o function 190 254 Edit a new white balance 15 14 13 255 Store a new white balance Chase Patterns 0 10 Led trun off 11 40 Chase 1 41 70 Chase 2 71 100 Chase 3 101 130 Chase 4 131 160 Chase 5 161 190 C...

Страница 26: ...t of the fixture if the yoke s magnetic indexing circuit malfunction sensor failed or magnet missing or the stepping motor is defective or its driving IC on the main PCB The PAN movement is not locate...

Страница 27: ...a moist lint free cloth Never use alcohol or solvents There are no serviceable parts inside the device except for the lamp Please refer to the instructions under Installation instructions Should you n...

Отзывы: