15
Warning indications
Low battery indication please replace
Over load indication. The weight subject on the
the battery
platform exceeds the maximum capicity of scale
Please step off to avoid damage.
Low fat percentage is to low.
High fat percentage is to high.
Error, please re-test to get the correct result.
About fat, hydration and calory
Fat % and hydration %
The fat% is an index % of fat content in human body.
The fat content in human body is of a certain level, overabundance of fat will
bring bad effects on metabolism, thereby, various illnesses may invade.Please consult your
doctor for more advice.
The hydration % is an index of hydration in a human body. A to high or to low percentage is
bad for your health, please advice your doctor
Fat/hydration content fitness assessment chart
After your weighing, you can use the following assessment charts for reference:
Chart age to 30 years
Fat %
Female
Hydration%
Female
Fat %
Male
Hydration%
Male
Status
Key line
indication
4.0-16.0
66.0-57.8
4.0-11.0
66.0-61.2
Too lean
|||||
16.1-20.5
57.5-54.7
11.1-15.5
61.1-58.1
Lean
||||| ||||
20.6-25.0
54.6-51.6
15.6-20.0
58.0-55.0
Normal
||||| |||| ||||
25.1-30.5
51.5-47.8
20.1-25.5
54.9-51.9
Fat
||||| ||||| ||||
||||
30.6-60.0
47.7-27.5
24.6-60.0
51.8-27.5
To fat
||||| ||||| |||||
||||| |||||
16
Chart age above 31 years
Fat %
Female
Hydration%
Female
Fat %
Male
Hydration%
Male
Status
Key line
indication
4.0-20.0
66.0-55.0
4.0-15.0
66.0-58.4
Too lean
|||||
20.1-25.0
54.9-51.6
15.1-19.5
58.3-55.3
Lean
||||| ||||
25.1-30.0
51.8-48.1
19.6-24.0
55.2-52.3
Normal
||||| |||| ||||
30.1-35.0
48.0-44.7
24.1-28.5
52.2-49.2
Fat
||||| ||||| ||||
||||
35.1-60.0
44.6-27.5
28.6-60.0
49.1-27.5
To fat
||||| ||||| |||||
||||| |||||
The above information is only for reference
Calorie
The data reading indicates the energy you need to sustain the daily metabolism and ordinary
activities required for your weight, height, age and gender.
Working principles
As electrical signal of certain frequency transmits through human body, the impedance of fat is
stronger than that of muscle or other human tissues. Through the use of biological resistance
analysis, this product will pass a safe frequency of low voltage electrical current through
human body, thus, the fat% will be reflected according to the resistance differences when the
electrical signal transmitting through human body.
Cleaning of the device
Clean the glass plate with a damp cloth, do not use harsh or abrasive cleaners. Do not use