background image

Switches

2 switches control off/on power status and alarm-cancel/self-test operation

SURGE / NOISE SUPPRESSION

UPS AC suppression
joule rating

570

UPS AC suppression
response time

Instantaneous

UPS Dataline
suppression

1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet

EMI / RFI AC noise
suppression

Yes

PHYSICAL

Installation form
factors supported
with optional
accessories

2 post rackmount (2POSTRMKITWM); Wallmount (2POSTRMKITWM); Tower (2-9USTAND)

Primary form factor

Rackmount

UPS / Power Module
dimensions in
primary form factor
(height x width x
depth / inches)

3.5 x 17.5 x 19

UPS / Power Module
dimensions in
primary form factor
(height x width x
depth / cm)

8.9 x 44.4 x 48.3

Installed whole
system dimensions in
secondary form factor
(height x width x
depth / cm)

44.4 x 8.9 x 48.3

Rack Height

2U

Secondary form factor

Tower (requires 

2-9USTAND

)

Installed whole
system dimensions in
secondary form factor
(height x width x
depth / inches)

17.5 x 3.5 x 19

UPS dimensions in
secondary form factor
(height x width x
depth / cm)

44.4 x 8.9 x 48.3

UPS / Power Module
weight (lbs)

47.4

UPS / Power Module
weight (kg)

21.5

UPS Shipping
dimensions (height x
width x depth / inches)

9.8 x 20.2 x 24

UPS Shipping
dimensions (height x
width x depth / cm)

24.8 x 51.4 x 61

Shipping weight (lbs)

57.3

Содержание SU2200RTXL2UN

Страница 1: ...liant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X Includes PowerAlert monitoring software and complete cabling Emergency Power Off EPO interface LED display reports UPS operating mode line power availability battery mode operation inverter operation and output power availability Audible alarm with push button momentary alarm c...

Страница 2: ...ower factor 0 7 Crest Factor 3 1 Nominal Output Voltage s Supported 110V 120V Nominal Voltage details 120V default Frequency compatibility 50 60 Hz Frequency compatibility details Output frequency matches input nominal on startup defaults to 60 Hz on cold start Output voltage regulation line mode 2 Output voltage regulation Economy line mode 10 Output voltage regulation Battery mode 2 Built in UPS...

Страница 3: ...ent description Hot swappable user replaceable sealed flame retardant non spillable batteries VOLTAGE REGULATION Voltage regulation description Online double conversion power conditioning Overvoltage correction 2 output voltage regulation during overvoltages to 150 Undervoltage correction 2 output voltage regulation during undervoltages to 80 Severe undervoltage correction 2 output voltage regulat...

Страница 4: ...height x width x depth inches 3 5 x 17 5 x 19 UPS Power Module dimensions in primary form factor height x width x depth cm 8 9 x 44 4 x 48 3 Installed whole system dimensions in secondary form factor height x width x depth cm 44 4 x 8 9 x 48 3 Rack Height 2U Secondary form factor Tower requires 2 9USTAND Installed whole system dimensions in secondary form factor height x width x depth inches 17 5 ...

Страница 5: ...PWEBCARD interface card Supports detailed monitoring of UPS and site power conditions PowerAlert software Included Communications cable USB and DB9 cabling included WatchDog compatibility Supports Watchdog application OS and hard reboot restart options for remote applications LINE BATTERY TRANSFER Transfer time No transfer time 0 ms in online double conversion mode Low voltage transfer to battery ...

Страница 6: ...120V 1U Horizontal Rackmount 13 NEMA 5 15 20R outlets NEMA 5 20P input plug 1 PDUV20 Single Phase Basic PDU 20A 120V 0U Vertical Rackmount 14 NEMA 5 15 20R outlets NEMA L5 20P input with 5 20P adapter 1 PDUMV20 Single Phase Metered PDU 20A 120V 0U Vertical Rackmount 28 NEMA 5 15 20R outlets NEMA L5 20P input with 5 20P adapter 1 PDUMH20AT Single Phase Auto Transfer Switch Metered PDU 20A 120V 1U H...

Отзывы: