compatible)
Line-interactive voltage regulation corrects brownouts and overvoltages from 155 to 274 volts back to usable 230V output levels, without
using battery power
Full line isolation prevents shock potential and operational problems in sensitive electronic equipment
Resistant to electrostatic discharge
Supports loads up to 1000VA/750W
27.5 min. half-load runtime (500VA/375W), 11 min. full load runtime (1000VA/750W)
6 protected outlets; 6-inch dongle with IEC C14 inlet
USB and DB9 communication ports
PowerAlert unattended shutdown software and complete cabling included
Complete surge protection, line isolation and EMI/RFI noise filtering
5 diagnostic LEDs indicate AC present, on battery, voltage correction, overload & battery low/replace
Battery replacement door and back panel grounding lug
Specifications
OUTPUT
Output Volt Amp
Capacity (VA)
1000
Output Watt Capacity
(watts)
750
Nominal Output
Voltage(s) Supported
230V
Frequency
compatibility
50/60 Hz (auto-selectable)
Output voltage
regulation (line mode)
-18%, +8%
Built-in UPS output
receptacles
6 C13 outlet(s)
INPUT
Rated input current (at
maximum load)
5A
Nominal Input
Voltage(s) Supported
230V AC
UPS input connection
type
C14 inlet
UPS Input cord length
(ft.)
6 inch dongle, 16 gauge
UPS Input cord length
(m)
1.83
Recommended
Electrical Service
10A 230V
Voltage compatibility
(VAC)
230
BATTERY
Full load runtime
(minutes)
11 min. (750w)
Half load runtime
(minutes)
27.5 min. (375w)
Expandable battery
runtime
Supports extended runtime with optional
BP36V15-2U
(limit 1) and
BP36V42-3U
external battery pack (multi-pack