background image

C

US

UL

1778

Owner’s Manual

1111 W. 35th Street  Chicago, IL 60609 USA

Customer Support: (773) 869-1234 • www.tripplite.com

Important Safety Instructions

2

Mounting

3

Connection

5

Basic Operation

7

Storage and Service

10

Copyright © 2002 Tripp Lite.  All rights reserved. SmartPro

®

is a registered trademark of Tripp Lite.

SmartPro

®

RMX 

1000-2000 VA

120V Input/Output UPS Systems

Intelligent • Line-Interactive • Industrial Cabinet

Specifications

10

200208099 93-2040 SM1000RMX Owner’s Manual.qxd  9/12/2002  3:53 PM  Page 1

Содержание SmartPro RMX RMX 1000-2000 VA

Страница 1: ...unting 3 Connection 5 Basic Operation 7 Storage and Service 10 Copyright 2002 Tripp Lite All rights reserved SmartPro is a registered trademark of Tripp Lite SmartPro RMX 1000 2000 VA 120V Input Output UPS Systems Intelligent Line Interactive Industrial Cabinet Specifications 10 200208099 93 2040 SM1000RMX Owner s Manual qxd 9 12 2002 3 53 PM Page 1 ...

Страница 2: ...connect extension cords or surge suppressors to the output of your UPS This may damage your UPS and will void both the surge suppressor and UPS warranties Battery Warnings Your UPS does not require routine maintenance Do not open your UPS for any reason except battery replacement There are no user serviceable parts inside Battery replacement must be performed by qualified service personnel Because...

Страница 3: ...user supplied rack bolts D through its mounting ears and into the rack s side supports 2 Suggested Rackmount Installation for the SM1000RMX Mounting Suggested 4 Post Rackmount Installation for the SM2000RMX 1 Connect the three segments of each shelf A using the included screws nuts and washers B Leave the screws slightly loose so that the shelves can be adjusted in the next step Adjust each shelf ...

Страница 4: ...ls 3 1 Attach the four mounting shelf segments shown A to both rack posts B with the screws nuts and washers provided C Note that the side supports should face inward Attach mounting ears D to the middle mounting holes of your UPS E using the screws and washers provided F Do not attach the mounting ears to your equipment s front holes Using an assistant if necessary lift your UPS and slide it onto...

Страница 5: ...your equipment into your UPS Your UPS is designed to support only computer equipment You will overload your UPS if you connect household appliances laser printers or surge suppressors to the UPS s outlets Turn your UPS ON Press the POWER button Hold the button for a moment until the LED stops flashing and illuminates constantly Release the button Your UPS is now ON and its AC outlets are active Co...

Страница 6: ...ripp Lite power protection software appropriate to its operating system If your UPS has two USB ports a second computer with a USB port may be connected if desired EPO Port Connection Select Models Only Using the RJ11 cable provided connect the Emergency Power Off EPO port of your UPS to a user supplied normally closed or normally open switch according to the circuit diagram below The EPO port is ...

Страница 7: ...Your UPS has three alarms The first the INVERT alarm emits four short beeps every ten seconds when the UPS is in INVERT mode to warn you that AC power has failed The second the OVERLOAD alarm emits short rapid beeps when the UPS is in INVERT mode if the total power draw of connected equipment exceeds the UPS s output capacity to warn you to reduce the load The third the Low Battery alarm emits a c...

Страница 8: ... and shut down your equipment immediately OUTPUT LOAD This multicolored light shows how heavy your UPS s load is Steady green indicates a light load steady yellow a medium load When the light is red your UPS is supporting a load above 85 of its capacity If the red light begins flashing then your UPS is severely overloaded Immediately remove load from the UPS until the light stops flashing BATTERY ...

Страница 9: ...ent during a blackout see Connection page 5 EPO Emergency Power Off Port Select models only Your UPS may have an EPO port that can be used to connect the UPS to a con tact closure switch to enable emergency inverter shutdown see Connection page 5 Accessory Slot Select models only Remove the small cover panel from this slot to use optional accessories to remotely monitor and control your UPS Contac...

Страница 10: ... 147 volts Voltage Regulated Output Voltage Range 120 9 On Battery Output Voltage Range 120 5 Output Waveform Line Mode filtered sinewave Output Waveform Battery Mode PWM sine wave AC Surge Suppression exceeds IEEE 587 Cat A B standards AC Noise Attenuation 40 dB AC Surge Protection Modes H to N H to G N to G This device complies with part 15 of the FCC Rules Operation is subject to the following ...

Страница 11: ...11 200208099 93 2040 SM1000RMX Owner s Manual qxd 9 12 2002 3 53 PM Page 11 ...

Страница 12: ...93 2040 200208099 200208099 93 2040 SM1000RMX Owner s Manual qxd 9 12 2002 3 53 PM Page 12 ...