16
IEC 320-C13
IEC 320-C19
Basic Operation
continued
Other UPS Features (Rear Panel)
AC Outlets:
All models include IEC 320-C13 outlets. Select models also
include IEC 320-C19 outlets. These outlets provide your connected equipment
with AC line power during normal operation and battery power during blackouts
and brownouts. The UPS protects equipment connected to these outlets against
damaging surges and line noise. If you have a serial or USB connection to your
UPS, you can remotely reboot connected equipment by turning the outlets OFF
and ON using Tripp Lite’s PowerAlert Software. The outlets are divided into one
or more load banks (labelled “LOAD 1,” etc.) which may be remotely switched
OFF and ON without interrupting power to equipment connected to the other
outlets. Outlets labelled “UNSWITCHED” may not be remotely switched off.
Communications Ports (USB or RS-232):
These ports connect your UPS to
any workstation or server. Use with Tripp Lite’s PowerAlert Software and included
cables to enable your computer to automatically save open files and shut down
equipment during a blackout. Also use PowerAlert Software to monitor a wide
variety of AC line power and UPS operating conditions. Consult your PowerAlert
Software manual or contact Tripp Lite Customer Support for more information.
See “USB and RS-232 Serial Communications” in the “Optional Installation”
section for installation instructions.
EPO (Emergency Power Off) Port:
Your UPS features a EPO port that may be
used to connect the UPS to a contact closure switch to enable emergency
inverter shutdown. See Optional Installation.
Accessory Slot:
Remove the small cover panel from this slot to install optional
accessories to remotely monitor and control your UPS. Refer to your accessory’s
manual for installation instructions. Contact Tripp Lite Customer Support at www.
tripplite.com/support for more information, including a list of available SNMP,
network management and connectivity products.
External Battery Connector (optional on select models):
Use to connect
Tripp Lite external battery packs for additional runtime. Refer to instructions
available with the battery pack for complete connection information and safety
warnings. Visit www.tripplite.com/support/battery/index.cfm to locate the
supported battery type(s) for your UPS.
Output Breaker (select models):
Your UPS features one or more breakers that
protect your UPS from output overload. If one or more breakers trip, remove
some of the load on the circuit(s), then reset them by pressing the breaker
switch(es) in.
13-09-055-93-3184.indb 16