Tripp Lite SmartOnline SU6000RT4UHVHW Скачать руководство пользователя страница 2

SNMPWEBCARD accessory can enable the UPS to operate as an IP managed device.

The unit requires only 4U of rack space in a standard rack enclosure and can be installed in a 2-post rack using the 2POSTRMKITHD accessory, or in a tower

configuration with the 2-9USTAND accessory.

The SU6000RT4UHVHW comes with $250,000 Ultimate Lifetime Insurance coverage for connected equipment and a 2-year warranty. 

Features

Tripp Lite SU6000RT4UHVHW 6000VA / 6kVA / 5400 watt on-line, double-conversion UPS system in a single 4U rack/tower compatible housing

Full-time active power conditioning maintains clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise

Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions

Detachable back panel PDU contains hardwire input and output connections, plus manual bypass switch to support hot-swappable whole UPS

replacement with no interruption to connected equipment

Hardwire input and output connections supported

Included rail kit supports 4U 19 inch rackmount installation in 4 post racks

Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks (1 required for SU6000RT4UHVHW)

Optional 2-9USTAND supports upright tower placement (1 required for SU6000RT4UHVHW)

Maximum installed rack depth of only 20.7 in. / 52.6cm inches

Maintains full-time sine wave output within 2% of selected 200/208/220/230/240V nominal in double conversion mode

Corrects brownouts to 156V at full load (100V at 50% load or less)

Corrects overvoltages to 290V at full load (300V at 90% load or less)

Supports 50/60Hz operation for worldwide frequency compatibility

Double-conversion operation offers full-time AC to DC, then DC to AC conversion to maintain perfectly regulated sine wave AC output with enhanced

protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types

High efficiency ECONOMY MODE operation significantly reduces BTU heat output and operating energy costs

Network-grade AC surge and noise suppression

Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in RS-232, USB and optional SNMP card slot

interfaces

UPS card slot supports one card-based network interface option (part # SNMPWEBCARD) or dry-contact monitoring accessory (part # RELAYIOCARD)

Optional SNMPWEBCARD offers communications and control via secure remote web and network interfaces

Optional RELAYIOCARD supports six configurable hard contact closure outputs for custom event notification

Optional RELAYIOMINI interface module offers three configurable hard contact closure outputs for custom event notification (requires removal of USB

interface module)

HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X

Includes Free PowerAlert monitoring software packages; PowerAlert LOCAL for desktops and small business networks, PowerAlert NSA (Network

Shutdown Agent) for larger networks and PowerAlert NMS (Network Management System) for monitoring up to 250 SNMP-enabled UPS, PDU and other

networking devices

Front panel LEDs and LCD readout with scroll controls support front-panel visual monitoring of all major

UPS functions with support for a variety of control options to support advanced UPS settings and configurations

LED/LCD display panel rotates for viewing in rackmount or tower configurations

Supports Emergency Power Off (EPO) via built-in interface

Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and

require replacement

BP192V12-3U external battery packs are field replaceable and hot swappable

Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)

2 / 7 

 

Содержание SmartOnline SU6000RT4UHVHW

Страница 1: ...6 economy mode setting that can significantly reduce a facility s energy costs by minimizing heat output reducing cooling requirements and consuming less electricity An LCD display with LED indicators enables IT personnel to operating modes and conditions The LCD LED panel rotates for viewing in horizontal rack or vertical tower installations and includes an audible alarm that signals various cond...

Страница 2: ...trical impulses and other hard to solve power problems not addressed by other UPS types High efficiency ECONOMY MODE operation significantly reduces BTU heat output and operating energy costs Network grade AC surge and noise suppression Supports detailed monitoring of equipment load levels self test data and utility power conditions via built in RS 232 USB and optional SNMP card slot interfaces UP...

Страница 3: ... 10 Output voltage regulation Battery mode 2 Built in UPS output receptacles Hardwire Output receptacle details Hardwire input and output connections are mounted on a detachable PDU backplate with bypass switch to enable hot swappable power module replacement Output AC waveform AC mode Pure Sine wave Output AC waveform battery mode Pure Sine wave INPUT Rated input current at maximum load 31 9A 200...

Страница 4: ...itional information and control options Alarms Unique audible alarms for all major UPS environmental and power conditions see manual Alarm cancel operation Alarm cancel switch Switches Includes main power off on switch plus 2 switches to set and execute scrollable LCD functions A manual bypass switch featured on the detachable PDU allows for complete removal of the UPS during routine maintenance w...

Страница 5: ...0 ft Audible Noise 60 dBA at front side 1 meter Operating Elevation m 0 3000 m COMMUNICATIONS Communications interface USB HID enabled DB9 Serial EPO emergency power off Slot for SNMP Web interface Network monitoring port description Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards RELAYIOMINI installation requires removal of panel containing USB ports P...

Страница 6: ...S System 1 2POSTRMKITHD Enables 2 Post Rackmount Installation of 3U and Larger UPS Transformer and Battery Pack Components 1 2 9USTAND Enables Tower Placement of Rackmount UPS Systems 1 SNMPWEBCARD For remote monitoring and control via SNMP Web or Telnet 1 ENVIROSENSE Monitors temperature humidity and contact closure inputs Requires SNMPWEBCARD or switched PDU 1 RELAYIOCARD Programmable Relay I O ...

Страница 7: ...Specifications are subject to change without notice Photos may differ slightly from final products 7 7 ...

Отзывы: