Replacement battery
cartridge (internal UPS
battery replacement)
RBC53
Battery Access
Battery access door
Battery replacement
description
Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage regulation
description
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 81 to 143
Overvoltage correction
Input voltages between 126 and 143 are reduced by 9%
Undervoltage correction
Input voltages between 96 and 106 are boosted by 10%
Severe undervoltage
correction
Input voltages between 81 and 95 are boosted by 21%
LEDS ALARMS & SWITCHES
LED Indicators
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
Alarms
Audible alarm indicates power-failure, overload and low-battery conditions
Alarm cancel operation
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate
low-battery status
Switches
2 Switches control off/on power status and alarm-cancel/self-test operation
SURGE / NOISE SUPPRESSION
UPS AC suppression joule
rating
480
UPS AC suppression
response time
Instantaneous
EMI / RFI AC noise
suppression
Yes
AC suppression joule rating
480
AC suppression response
time
Instantaneous
ISOLATION
Output isolation
transformer
Hospital grade load isolation transformer
Leakage current
Equal to 100 microamps
PHYSICAL
Installation form factors
supported with included
accessories
Tower
Installation form factors
supported with optional
accessories
Wallmount (UPSWM - tower mounting kit)
Primary form factor
Tower
UPS / Power Module
dimensions in primary
form factor (height x width
x depth / inches)
12.8 x 7.5 x 9