Tripp Lite SM750XLNAFTA Скачать руководство пользователя страница 6

More information, including related products, owner's manuals, and additional technical specifications, can be found online at 

www.tripplite.com/en/products/model.cfm?txtModelID=3549

Copyright © 2012 Tripp Lite. All rights reserved. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous

improvement. Specifications are subject to change without notice. Photos may differ slightly from final products.

Содержание SM750XLNAFTA

Страница 1: ...ations interfaces support messaging of UPS and line power status plus output power control for delayed or immediate reboot of all connected devices at once Includes PowerAlert UPS monitoring and unattended shutdown software with management support for an unlimited number of network UPS systems Built in audible alarm and 15 LEDs provide graphical readout of line power battery power battery charge l...

Страница 2: ...ntarily switching UPS power off and back on again requires optional WATCHDOGSW 15 LEDs offer continuous detailed status information of UPS operating parameters and site power quality Hot swappable batteries allow on site battery replacement without powering off connected equipment 2 year warranty with up to 250 000 connected equipment insurance Specifications OUTPUT Output Volt Amp Capacity VA 750...

Страница 3: ... regulation AVR maintains line power operation with an input voltage range of 95 to 145 120v 87 to 133 110v 83 to 121 100v Overvoltage correction Voltage reduction of 12 applies when input is 127 to 145 120v 116 to 133 110v 111 to 121 100v Undervoltage correction Voltage boost of 14 applies when input is 95 to 108 120v 87 to 99 110v 83 to 90 100v LEDS ALARMS SWITCHES LED Indicators 9 LEDs indicate...

Страница 4: ...h cm 33 x 25 4 x 60 3 Shipping weight lbs 50 Shipping weight kg 22 7 UPS housing material Steel Cooling method Fan ENVIRONMENTAL Operating Temperature Range 32 to 104 degrees Fahrenheit 0 to 40 degrees Celsius Storage Temperature Range 5 to 122 degrees Fahrenheit 15 to 50 degrees Celsius Relative Humidity 0 to 95 non condensing AC mode BTU hr full load 97 7 Battery mode BTU hr full load 270 Audibl...

Страница 5: ...t Read AC Outlet Circuit Tester 1 Extended Warranties WEXT3 500 1500 3 Year Extended Warranty For Smart Line Interactive and Online Tower or Rack models 1500VA or less 1 Extended Warranties WEXT5 500 1500 5 Year Extended Warranty For Smart Line Interactive and Online Tower or Rack models 1500VA or less 1 Power Distribution PDU1215 Basic PDU Power Distribution Unit Safe reliable power distribution ...

Страница 6: ...e at www tripplite com en products model cfm txtModelID 3549 Copyright 2012 Tripp Lite All rights reserved All trademarks are the sole property of their respective owners Tripp Lite has a policy of continuous improvement Specifications are subject to change without notice Photos may differ slightly from final products ...

Отзывы: