DIP Switch Settings
DIP Switch Settings
Number Label
Description
1
LLB
ON: LLB is enabled
OFF: LLB is disabled
2
LFS
ON: LFS is enabled
OFF: LFS is disabled
3
FX100 ON: Port 2 (SFP) speed at 100 Mbps
OFF: Port 2 (SFP) speed at 1000 Mbps
ALM (Alarm) DIP Switch Settings
4
PWR
ON: Master power alarm reporting is enabled
OFF: Master power alarm reporting is disabled
5
RPS
ON: Redundant power alarm reporting is enabled
OFF: Redundant power alarm reporting is disabled
6
LFS
ON: Alarm for LFS issue is triggered
OFF: Alarm LFS is disabled
Link Fault Signaling (LFS)
When the LFS DIP switch is enabled (#6), an alarm indicator will
illuminate to indicate when a cable has been severed or when some
other cause of disruption in service has occurred. The LFS function
monitors both copper and fiber segments for a total service report.
Line Loop Back Test (LLB)
Set DIP Switch 1 to “ON” to activate the LLB diagnostic test function. Use
the LLB function to check if the copper and fiber and fiber segments are
connected properly.