STEP 3: Plug your equipment into the UPS:

Select outlets will provide battery backup and surge pro-

tection; plug your computer, monitor and other critical devices here.* Select outlets will provide surge
protection only; plug your printer and other nonessential devices here. (See Basic Operation Section.)

* Your UPS is designed to support electronic equipment only. You will overload the UPS if the total VA ratings for all the equipment you

connect to the Battery Backup Protected/Surge Protected outlets exceeds the UPS’s Output Capacity. To find your equipment’s VA ratings,

look on their nameplates. If the equipment is listed in amps, multiply the number of amps by 120 to determine VA. (Example: 1 amp ×

120 = 120 VA). If you are unsure if you have overloaded the Battery Backup Protected/Surge Protected outlets, run a self-test 

(see “MUTE/TEST” Button description).

CAUTION: The UPS must be plugged into a live AC outlet and turned on for 24 hours after initial
installation to fully charge the UPS's internal battery. Your connected equipment will receive utili-
ty-supplied AC power (if present) immediately after the UPS is plugged in and turned on; howev-
er, your connected equipment may not receive full battery backup in the event of a blackout or
severe brownout until the UPS's internal battery is fully charged.

“ON/OFF” Button

• To turn the UPS on:

Press and hold the ON/OFF Button for one second.* 

If utility power is absent, pressing the Button will “cold-start” the UPS,
i.e. turn it on and supply power from its battery.** 

•To turn the UPS off:

Press and hold the ON/OFF Button for one second.*

The UPS will be turned completely off (deactivated).

* The alarm will beep once briefly after one second has passed. ** Runtime will be proportionate to the 

UPS battery's level of charge.

“MUTE/TEST” Button

• To Silence (or “Mute”) UPS Alarms:

briefly press and release the 

MUTE/TEST button. 

Note:

continuous alarms (warning you to shut down 

connected equipment immediately) cannot be silenced.

• To Run a Self-Test:

with your UPS plugged in and turned on, press and 

hold the MUTE/TEST button for two seconds. Continue holding the button 
until the alarm beeps several times and the UPS performs a self-test. 
See “Results of a Self-Test” below. 

Note:

you can leave connected 

equipment on during a self-test.

CAUTION! Do not unplug your UPS to test its battery. This will remove safe electrical 
grounding and may introduce a damaging surge into your network connections.

Results of a Self-Test: 

The test will last approximately 10 seconds as the UPS switches to battery to test

its load capacity and charge. All LCD Display icons will be illuminated and the UPS alarm will sound.

•If the “FAULT” icon remains lit and the alarm continues to sound after the test, the battery-

supported outlets are overloaded. To clear the overload, unplug some of your equipment from the 
battery-supported outlets and repeat the self-test until the “FAULT” icon is no longer lit and the 
alarm is no longer sounding. 

Note:

The alarm beeps once per minute.

CAUTION! Any overload that is not corrected by the user immediately following a self-test may cause
the UPS to shut down and cease supplying output power in the event of a blackout or brownout.

•If the “REPLACE” icon remains lit and the alarm continues to sound after the test, the UPS 

batteries need to be recharged or replaced. Allow the UPS to recharge continuously for 24 hours, 
and repeat the self-test. If the icon continues to illuminate after repeated self tests, contact 
Tripp Lite for service. Battery replacement should only be performed by qualified service 
personnel. If the UPS requires battery replacement, Tripp Lite offers a complete line of replacement
batteries at www.tripplite.com. 

Note:

The alarm beeps once per minute.

Quick Installation 

(Continued)

Basic Operation 

(Front Panel)

3

ON/OFF Button

1

MUTE/TEST Button

2

1

2

200703079 OM Digital UPS.qxd  4/11/2007  10:28 AM  Page 3

Содержание Digital UPS Systems 200703079

Страница 1: ...TY REGISTRATION register online today for a chance to win a FREE Tripp Lite product www tripplite com warranty Important Safety Instructions 2 Quick Installation 2 Basic Operation 3 Warranty Registrat...

Страница 2: ...r batteries Do not short or bridge the battery terminals with any object Unplug and turn off the UPS before performing battery replacement Use tools with insulated handles There are no user serviceabl...

Страница 3: ...briefly press and release the MUTE TEST button Note continuous alarms warning you to shut down connected equipment immediately cannot be silenced To Run a Self Test with your UPS plugged in and turne...

Страница 4: ...ecting AC line voltage without depleting battery power This is a normal automatic operation of your UPS and no action is required on your part 3d REPLACE Battery Recharge Replace Icon This icon will i...

Страница 5: ...nnect a phone cord from the Tel DSL jack labeled OUT directly to the device to be protected The UPS system must always be the first item connected in line from the wall jack The UPS system must be plu...

Страница 6: ...n tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference i...

Страница 7: ...1111 W 35th Street Chicago IL 60609 USA 773 869 1234 USA 773 869 1212 International www tripplite com...

Отзывы: