![Tripp Lite B110-SP-CAT Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/tripp-lite/b110-sp-cat/b110-sp-cat_quick-start-manual_1166871004.webp)
4
Installation
Multiple Device Protection:
Note:
The maximum distance between any two In-Line HDBaseT & 10G Network
Surge Protectors is 328 ft. (100 m).
1.
Disconnect the installed patch cables from both of the devices you wish to
protect.
2.
Connect an In-Line HDBaseT & 10G Network Surge Protector to each end
of the previously uninstalled patch cable, ensuring both ends of the patch
cable are connected to the “Cable End” of the In-Line HDBaseT & 10G
Network Surge Protector.
3.
Using Cat5/5e/6 patch cables (not included), connect the “Equipment
End” of each In-Line HDBaseT & 10G Network Surge Protector to the
network devices you wish to protect.
Note:
For best protection performance, the Cat5/5e/6 patch cable between the
“Equipment End” of the In-Line HDBaseT & 10G Network Surge Protector and the
network equipment to be protected should not exceed 300 ft. (90 m). Tripp Lite’s
N001-Series Cat5e Snagless Patch Cables are recommended.
4.
Connect the ground wire to each In-Line HDBaseT & 10G Network Surge
Protector and then to earth ground.
PC
HDBaseT TX and Source
(Protected)
HDBaseT RX and Device
(Protected)
Equipment End
Cable End
Monitor
HE02ER
Equipment End
Cable End
328 ft. / 100 m
4K @ 60 Hz
18-10-218-9338D4.indb 4