background image

Overview

Because the B013-000 Console Extender System allows access to a
computer system from a remote console (keyboard, monitor, and
mouse), it is perfect for factory and construction sites, or any type of
installation where the console needs to be kept in a conveniently
accessible location, but you want the system equipment to reside in a
safe place - away from dust, dirt, and harsh environmental influences.

The B013-000 System is also useful for control and security
purposes, where you can have the system unit in a secure area at the
same time that you put the console in a location that offers convenient
access.

The B013-000 Console Extender provides the ideal means to access
the remote system box, since it improves on previous designs by
using inexpensive Category 5 STP cable - the kind commonly used in
Ethernet networks - instead of bulkier, more expensive, standard
cables, and can also sense the distance to the system and
automatically adjust thegain.

Category 5 cabling makes for a much neater, more convenient, more
reliable data transfer connection. Setup is as easy as can be - simply
connect the PC system box and local console to the Local B013-000
Module; run the STP cable to the Remote B013-000 Module (up to
150 meters away); and plug the remote console into the Remote
Module.

Note: You can control numerous remote systems from a single

console by combining the B013-000 with a KVM switch.

2001-02-05

- 2 -

Содержание B013-000

Страница 1: ...DER Model B013 000 NOTE Follow these installation and operating procedures to ensure correct performance and to prevent damage to this unit or to its connected devices Copyright 2000 Tripp Lite All rights reserved All trademarks are the property of their respective owners Technical specifications are subject to change without notice ...

Страница 2: ...onvenient access The B013 000 Console Extender provides the ideal means to access the remote system box since it improves on previous designs by using inexpensive Category 5 STP cable the kind commonly used in Ethernet networks instead of bulkier more expensive standard cables and can also sense the distance to the system and automatically adjust thegain Category 5 cabling makes for a much neater ...

Страница 3: ...sync Monitors l Local Monitor Supports DDC DDC2 DDC2B l Automatic Gain Control System Requirements Consoles l A VGA SVGA or Multisync monitor capable of the highest resolution that you will be using on any PC in the installation l A PS 2 style keyboard l A PS 2 style mouse Note 1 If you connect a DDC type monitor to the Local unit the monitor that connects to the Remote unit must be able to suppor...

Страница 4: ...bles l Although it is possible to use standard extender cables to link computers with PS 2 type keyboard and mouse ports to the B013 000 Local for optimum signal integrity and to simplify the layout we strongly recommend that you use the high quality CS Custom KVM Cable that is provided with this package l It is not possible to use standard extender cables to link computers with AT type keyboard a...

Страница 5: ...em s M Auto both consoles can control the system s 2 LEDs The Local Unit has two LEDs to indicate the operating status of the Local and Remote units see p 8 for details 3 Mouse Port The local PS 2 mouse plugs into this connector 4 Keyboard Port The local PS 2 keyboard plugs into this connector 5 Monitor Port The local monitor plugs into this connector 1 2 3 6 4 5 7 C O N S O L E R E M O T E I O AC...

Страница 6: ...able that connects to the computer s VGA port plugs into this connector 2 Keyboard Port The extension cable that connects to the computer s Keyboard port plugs into this connector 3 Mouse Port The extension cable that connects to the computer s Mouse port plugs into this connector Note If you are combining the B013 000 with a KVM switch the extension cable connects back to the respective ports on ...

Страница 7: ...The remote PS 2 mouse plugs into this connector 3 Keyboard Port The remote PS 2 keyboard plugs into this connector 4 Monitor Port The remote monitor plugs into this connector 5 Remote I O The Category 5 twisted pair cable that connects back to the Local Unit plugs into this connector 6 Power Jack The cable from the AC Power Adapter plugs into this jack CO NSO LE REMOTE I O AC 9V 1 2 3 4 5 6 7 ...

Страница 8: ...d of the cable into the appropriate ports on the PC system or Console section of the KVM switch if you are using one Each connector is marked with an appropriate icon to indicate which it is 5 Plug either end of the Category 5 twisted pair cable into the B013 000 Local s Remote I O port 6 Plug one of the power adapters supplied with this package into an AC source plug the adapter s power cable int...

Страница 9: ...ote LED when neither console is active Remote The LED is Off 1 Lights when the remote console is active the Local LED is out 2 Turns off when the local console is active the Local LED turns on 3 Flashes on and off alternately with the Local LED when neither console is active B013 000 Remote Remote Unit LED Indication Power 1 Lights steadily to indicate that the connection to the Local Unit is ok 2...

Страница 10: ...bles are securely plugged into their sockets TP Wiring Diagram TP Pin Assignments Pin Assignment 1 V OUT B 2 V OUT B 3 V OUT G 4 V OUT R 5 V OUT R 6 V OUT G 7 DO 8 DO JACK POSITIONS PAIR 2 PAIR 1 PAIR 3 PAIR 4 T568B AT T 258A W O W G O G W Br Br Bl W Bl 1 2 3 4 5 6 7 8 10 ...

Страница 11: ...1 x 15 pin HDB female 1 x 15 pin HDB female Unit To Unit 8P8C Jack LEDs 1 Local 1 Remote 1 Power On 1 On Line Function Keys Local Auto Select button N A Cable Length 150m 500 max Video Resolution 1024 x 768 DDC DDC2 DDC2B Power Consumption AC 9V 300mA max Housing Plastic Weight 300 g 220 g Dimensions L x W x H 130 x 100 x 35 mm 100 x 80 x 35 mm DDC DDC2 and DDC2B support is for the Local monitor o...

Страница 12: ...aterials and workmanship for a period of one 1 year from the date of initial purchase TRIPP LITE s obligation under this warranty is limited to repairing or replacing at its sole option any such defective products To obtain service under this warranty you must obtain a Returned Material Authorization RMA number from TRIPP LITE or an authorized TRIPP LITE service center Products must be returned to...

Страница 13: ... 13 ...

Страница 14: ... 14 ...

Страница 15: ... 15 ...

Страница 16: ...PAPE 1142 203 16 ...

Отзывы: