background image

2A

Specifications

Note on Labeling  

Two symbols are used on the APS labels.

V~

: AC Voltage            : DC Voltage

Limited Warranty

Tripp Lite warrants its Inverter/Chargers to be free from defects in materials and workmanship for a period of one year (except for outside of U.S.A., Canada and Mexico—120 days) from the date of retail purchase by end user

Tripp Lite’s obligation under this warranty is limited to repairing or replacing (at its sole option) any such defective products. To obtain service under this warranty you must obtain a Returned Material Authorization (RMA) number from Tripp Lite or an authorized
Tripp Lite service center. Products must be returned to Tripp Lite or an authorized Tripp Lite service center with transportation charges prepaid and must be accompanied by a brief description of the problem encountered and proof of date and place of pur-
chase. This warranty does not apply to equipment which has been damaged by accident, negligence or misapplication or has been altered or modified in any way, including opening of the unit’s casing for any reason. This warranty applies only to the orig-
inal purchaser who must have properly registered the product within 10 days of retail purchase.

EXCEPT AS PROVIDED HEREIN, TRIPP LITE MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Some states do not permit limitation or exclu-
sion of implied warranties; therefore, the aforesaid limitation(s) or exclusion(s) may not apply to the purchaser.

EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL TRIPP LITE BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT, EVEN IF ADVISED OF THE POS-
SIBILITY OF SUCH DAMAGE. Specifically, Tripp Lite is not liable for any costs, such as lost profits or revenue, loss of equipment, loss of use of equipment, loss of software, loss of data, costs of substitutes, claims by third parties, or otherwise.

Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice.

Inverter/Charger DC Volt: 12

Wire Gauge

Watts

6

4

2

0

00 (2/0)

500

4.8 m (15 ft)

7.6 m (25 ft)

11.9 m (39 ft)

18.9 m (62 ft)

24.1 m (79 ft)

700

3.4 m (11 ft)

5.5 m (18 ft)

8.5 m (28 ft)

13.4 m (44 ft)

17.1 m (56 ft)

Minimum Recommended Cable Sizing Charts

Use in conjunction with DC wiring connection instructions in the Battery Connection section.

† NOTE: Acceptable power is directly related to cable length (i.e. - the shorter the cable, the better the performance)

MODEL NUMBER:

APSINT612

AC Input Connection:

Detachable Input Cord

INVERTER

Output Volts (Nominal):

230 VAC, ± 5%

Output Frequency (Nominal):

50 Hz, ± 0.5%

Efficiency:

88% to 94%, depending on load and temperature

Continuous Power (@ 20 C):

600

OverPower™ Peak Surge Power:*

900

Double Boost™ Peak Surge Power:*

1200

DC Input Volts (Nominal):

12 VDC

DC Input Voltage Range:

10-15 VDC

Minimum DC Fuse Rating:

100 A

DC Input Current @ Nominal V DC Full Load:

56 A

BATTERY CHARGER

Input Volts (Nominal):

230 VAC

Charging Capacity DC:

20 A

Acceptance Volts VDC Selectable (Wet**/Gel):

                                                           

14.4 V

 (

14.2 V

)

Float Volts VDC (w/gel):

13.3 V (13.6 V)

Input Current AC (Maximum): 

2.2

 A

LINE VAC OPERATION

Minimum Input Volts (Transfer to Battery):

Selectable 144,** 163, 182 or 201 VAC

Maximum Input Volts (Transfer to Battery):

Selectable 259** or 278 VAC

Input Frequency (Nominal):

50 Hz, ±10%

Total Input AC Current (Continuous, Charger at Maximum): 

4.8

 A

Maximum Output Current (Continuous):

2.6 A

* OverPower duration (up to 1 hour). DoubleBoost duration (up to 10 seconds). Actual duration depends on battery age, battery charge level and ambient temperature. ** Factory setting. 
The policy of Tripp Lite is one of continuous improvement. Specifications are subject to change without notice. 

Содержание APSINT612

Страница 1: ...Better for Your Equipment Premium Protection Levels Built In Surge Protection Automatic Overload Protection Ideal Output for All Loads including computers Frequency Controlled Output Fast Load Switch...

Страница 2: ...ly Tripp Lite is not liable for any costs such as lost profits or revenue loss of equipment loss of use of equipment loss of software loss of data costs of substitutes claims by third parties or other...

Страница 3: ...ad air compartment Ideally any compartment would have some ventilation to outside air Sparks may result during final battery connection Always observe proper polarity as batteries are connected Do not...

Страница 4: ...tive traffic light signals show approximate charge level of your battery See page 5 for instructions on reading indicator lights DC Power Terminals connect to your battery terminals See page 9 for con...

Страница 5: ...generator source If the operating mode switch is set to CHARGE ONLY this light will FLASH to alert you that the unit s inverter is OFF and will NOT supply AC power in the absence of a utility generato...

Страница 6: ...A3 Up 182V A4 Up A3 Down 163V A4 Down A3 Up 144V A4 Down A3 Down factory setting Most of your connected appliances and equipment will perform adequately when your Inverter Charger s High AC Input Vol...

Страница 7: ...timate you will operate your equipment exclusively from battery power before you have to recharge your batteries with utility or genera tor supplied AC power Compensate for inefficiency by multiplying...

Страница 8: ...elow User must supply mounting hardware and is responsible for determining if the hardware and mounting surface are suitable to support the weight of the Inverter Charger Contact Tripp Lite if you req...

Страница 9: ...of the cabling running from the battery to the unit Use the shortest length and largest diameter cabling maximum 2 0 gauge to fit your Inverter Charger s DC Input terminals Shorter and heavier gauge c...

Страница 10: ...output receptacle on the Inverter Charger AC Output Connection Simply connect equipment directly to the IEC 320 and NEMA output receptacles A universal adapter included allows you to connect a wide va...

Страница 11: ...ry damage The problem may be with connected Switch to OFF Wait 1 minute and switch to AUTO REMOTE or auxiliary chargers if any or with the unit s charger CHARGE ONLY If unit remains in shutdown mode a...

Страница 12: ...200302117 93 2113 1111 W 35th Street Chicago IL 60609 USA Customer Support 773 869 1212 www tripplite com...