Triplett SLDL20 Скачать руководство пользователя страница 8

 
 

quickly changing levels. Selection of Fast or Slow is determined by 
the application and any directives or standards related to that 
application. 

7. 

The Manual and Automatic select buttons allow the user to start 
data logging immediately (Auto) or at a later time (Manual).  

 

Click the SETUP button to save changes. Press the DEFAULT button to 
return the Logger to its factory default condition. Press the CANCEL 
button to abort the setup. 

 
Note: Displayed data will be permanently erased when “Setup” is selected. 
To save the displayed data, Select “Cancel” and then use the data 
Download and Save functions to save the data. 

 

Note: Always ensure that the remaining charge in the battery is sufficient 
to last the complete duration of the logging exercise. If in doubt, install a 
fresh battery before logging critical data. 

 

Logging Readings with the Datalogger 
 

1. 

Configure the Datalogger using the software as explained in this 
HELP utility. 

2. 

MANUAL LOGGING START: With the datalogger in the Manual 
mode (configured using the Datalogger Setup screen) and 
disconnected from the PC, press and hold the Datalogger’s push-
button for approx. 5 seconds to start logging readings; the LEDs will 
flash Red, Green, and then Yellow indicating that logging has begun. 

3. 

AUTOMATIC LOGGING START: With the datalogger in the 
Automatic mode (configured using the Datalogger Setup screen) the 
Datalogger will start immediately. The LEDs will flash Red, Green, 
and then Yellow indicating that datalogging has begun. 

4. 

During measurement sessions, the green LED flashes at the 
frequency selected in the Datalogger Setup screen. 

5. 

When the Datalogger memory is full, the yellow LED will flash for 10 
seconds. 

6. 

If the battery voltage runs critically low, the LEDs will display Red and 
Green lights simultaneously. 

Содержание SLDL20

Страница 1: ...User Manual SLDL20 Sound Level Datalogger...

Страница 2: ...ons The data logger is supplied with a long life lithium battery This meter is shipped fully tested and calibrated and with proper use will provide years of reliable service Safety Information Read th...

Страница 3: ...top 2 Remove the two Phillips head screws that secure the battery compartment at the back of the meter 3 Open the battery compartment and replace the 3 6V lithium battery observing correct polarity 4...

Страница 4: ...rd disk space for Datalogger USB software Monitor display resolution of 1024 x 768 with High Color 16 bit Main Menu File Save Save the recorded data to the disk Open Open a saved file Print Setup Chan...

Страница 5: ...info dialog window Help About Display the software version number Help Topics Display the software help document Cal Adjust Calibration Adjustment The Cal Adjust feature corrects for error in the out...

Страница 6: ...to 5 0 5dB to correct for the 0 5db error Click OK and the Total calibrated value is 5 statement will appear The calibration is now complete Datalogger Setup Click the icon on the menu bar The Setup...

Страница 7: ...RT real time where readings are displayed in real time on a PC 5 The Datalogger frequency weighting can be set to dBA or dBC Note With A weighting selected the meter responds like the human ear boosti...

Страница 8: ...e logging critical data Logging Readings with the Datalogger 1 Configure the Datalogger using the software as explained in this HELP utility 2 MANUAL LOGGING START With the datalogger in the Manual mo...

Страница 9: ...Datalogger software program 3 Click the Download icon 4 The window shown below will appear Click DOWNLOAD to begin transferring readings The logger will be empty of data once readings are transferred...

Страница 10: ...it record speed MAX reading MIN reading and AVG reading Zoom in 1 Click the left mouse button and drag a rectangle around the data area to be expanded 2 Release the mouse button 3 Use the horizontal s...

Страница 11: ...s Setup Input the desired data range X Axis Setup Input the desired number of data points The graph will appear based on the corresponding settings Set the background color grid color and sound graph...

Страница 12: ...view sound and low high alarms Check to add the x or y axes Mark Points Use dots on the traces that represent the actual data points essentially breaking up the continuous nature of the traces Import...

Страница 13: ...ith the sound extension to be reopened in the Datalogger software program and also as a xls file to be opened in a spreadsheet program To open an existing data file for viewing on the data graph windo...

Страница 14: ...on Green LEDflash Memory Full Indication Yellow LEDflash Data Output USB data traffic Power One 3 6 battery specs 14250 or 1 2AAA Electric Current When measuring 5 5mA when periphery power is o ff or...

Страница 15: ...ot apply to any of our products which have been repaired or altered by unauthorized persons in any way or purchased from unauthorized distributors so as in our sole judgment to injure their stability...

Отзывы: